Florence De La Barrière

Dr. Florence De La Barrière


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 February 2011 in Applied Optics
Verified
Journal Article
Closed access
PDF file
FBFlorence De La Barrière
Florence De La Barrière
GDGuillaume Druart
Guillaume Druart
NGNicolas Guérineau
Nicolas Guérineau
JTJean Taboury
Jean Taboury
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.

5 March 2012 in Applied Optics
Verified
Journal Article
Closed access
PDF file
FBFlorence De La Barrière
Florence De La Barrière
GDGuillaume Druart
Guillaume Druart
NGNicolas Guérineau
Nicolas Guérineau
GLGilles Lasfargues
Gilles Lasfargues
MFManuel Fendler
Manuel Fendler
JTJean Taboury
Jean Taboury
We present a compact infrared cryogenic multichannel camera with a wide field of view equal to 120°. By merging the optics with the detector, the concept is compatible with both cryogenic constraints and wafer-level fabrication. The design strategy of such a camera is described, as well as its fabrication and integration process. Its characterization has been carried out in terms of the modulation transfer function and the noise equivalent temperature difference (NETD). The optical system is limited by the diffraction. By cooling the optics, we achieve a very low NETD equal to 15 mK compared with traditional infrared cameras. A postprocessing algorithm that aims at reconstructing a well-sampled image from the set of undersampled raw subimages produced by the camera is proposed and validated on experimental images.

28 April 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PDPierre Delullier
Pierre Delullier
GDGuillaume Druart
Guillaume Druart
FBFlorence De La Barrière
Florence De La Barrière
LCLaurent Calvez
Laurent Calvez
MLMatthieu Lancry
Matthieu Lancry
Chalcogenide glasses have attracted growing interest for their potential to meet the demands of photonic applications in the Mid-Wavelength InfraRed (MWIR) and Long-Wavelength InfraRed (LWIR) transmission windows. In this work, we investigated the photosensitivity to femtosecond laser irradiation of a dedicated chalcogenide glass, along with its possible applications in micro-optics. In order to address the SWaP problem (Size, Weight and Power), this work took advantage of recent techniques in femtosecond laser direct writing to imprint flat and integrated optical systems. Here, we wanted to simplify an infrared multispectral imaging system which combines a lens array and a filter array. Each channel has a focal length of 7 mm and an f-number of 4. We show in this paper that the chosen GeS2-based chalcogenide glass is very promising for the fabrication of graded index optics by fs-laser writing, and particularly for the fabrication of Fresnel lenses. We note a very important phase variation capacity in this infrared material corresponding to refractive index variations up to +0.055. A prototype of Fresnel GRIN lens with a refractive index gradient was fabricated and optically characterized in the Vis range.

14 May 2010 in Applied Optics
Verified
Journal Article
Closed access
PDF file
FBFlorence De La Barrière
Florence De La Barrière
GDGuillaume Druart
Guillaume Druart
NGNicolas Guérineau
Nicolas Guérineau
JTJean Taboury
Jean Taboury
JPJérôme Primot
Jérôme Primot
JDJoël Deschamps
Joël Deschamps
We present a new method to measure the modulation transfer function (MTF) beyond the Nyquist frequency of a multichannel imaging system for which all the channels have parallel optical axes. Such a multichannel optical system produces a set of undersampled subimages. If the subimages contain nonredundant information, high spatial frequencies are folded between low spatial frequencies, leading to the possible extraction of frequencies higher than the Nyquist frequency. The measurement of the MTF of the multichannel system leads to the estimation of the resolution enhancement of the final image that can be obtained by applying a postprocessing algorithm to the collection of undersampled subimages. Experimental images are presented to validate this method.

29 February 2012 in Journal of Electronic Materials
Verified
Journal Article
Closed access
PDF file
FBFlorence De La Barrière
Florence De La Barrière
GDGuillaume Druart
Guillaume Druart
NGNicolas Guérineau
Nicolas Guérineau
SRSylvain Rommeluère
Sylvain Rommeluère
LMLaurent Mugnier
Laurent Mugnier
SDSophie Derelle
Sophie Derelle

6 June 2018 in Applied Optics
Verified
Journal Article
Closed access
PDF file
FBFlorence De La Barrière
Florence De La Barrière
GDGuillaume Druart
Guillaume Druart
NGNicolas Guérineau
Nicolas Guérineau
FCFrédéric Champagnat
Frédéric Champagnat
APAurélien Plyer
Aurélien Plyer
SMSerge Magli
Serge Magli
We present an ultracompact infrared cryogenic camera integrated inside a standard Sofradir’s detector dewar cooler assembly (DDCA) whose field of view is equal to 120°. The multichannel optical architecture produces four nonredundant images on a single SCORPIO detector with a pixel pitch of 15 μm. This ultraminiaturized optical system brings a very low additional optical and mechanical mass to be cooled in the DDCA: the cool-down time is comparable to an equivalent DDCA without an imagery function. Limiting the number of channels is necessary to keep the highest number of resolved points in the final image. However, optical tolerances lead to irregular shifts between the channels. This paper discusses the limits of multichannel architectures. With an image-processing algorithm, the four images produced by the camera are combined to process a single full-resolution image with an equivalent sampling pitch equal to 7.5 μm. Experimental measurements on the modulation transfer function and noise equivalent temperature difference show that this camera achieves good optical performance.