Hisham M. Soliman

Prof. Dr. Hisham M. Soliman

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 January 2023 in Energies
Verified
Journal Article
Open access
PDF file
HSHisham M. Soliman
Hisham M. Soliman
Ashraf SaleemAshraf Saleem
Ashraf Saleem
Ehab H. E. BayoumiEhab H. E. Bayoumi
Ehab H. E. Bayoumi
Michele De SantisMichele De Santis
Michele De Santis
A photovoltaic generator connected to a large network and supplying a nonlinear load (source of harmonics) injects distorted current into the grid. This manuscript presents an invariant-ellipsoid set design of a robust controlled active power filter to inject current into the large grid with minimum total harmonic distortion (THD). The nonlinear load current is considered an external disturbance to minimize its effect on the injected grid current. Moreover, the large grid is modeled as a fixed voltage source in a series with a Thevenin impedance whose value changes within an interval. Using the invariant-ellipsoid technique, the problem is cast as a robust disturbance-rejection tracking control. The volume of the ellipsoid is minimized, which results in minimizing the effect of disturbance on system performance and keeping the trajectories as close as possible to the origin. The design is cast into a set of nonlinear matrix inequalities that are linearized by fixing a scalar. The resulting convex optimization is solved iteratively by linear matrix inequalities (LMIs). The simulation and experimental findings show that the proposed design is successful in reducing THD injected into the grid when grid impedance is uncertain and variable loads are applied (balanced and unbalanced cases).

16 August 2017 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
HSHisham M. Soliman
Hisham M. Soliman
KMKhaled A. El Metwally
Khaled A. El Metwally
This study presents a design method of power system stabilisers (PSSs) to damp system oscillations. The design is based on fuzzy logic and linear matrix inequality (LMI) techniques. The design guarantees a robust pole placement in a desired region in the complex plane for different loading conditions. Due to system non‐linearity and load dependency, the whole wide range of operating condition is divided into three subregions. For each subregion, a norm‐bounded uncertainty linear model is developed and a robust LMI‐based pole placer is designed considering controller constraint. Takagi–Sugeno fuzzy model is used to guarantee smoothly switching between the LMI‐based controllers of the three subregions. The proposed technique avoids solving many LMIs as in the polytypic approach and avoids the infeasibility problem that might arise from solving the LMIs for the complete region of operation. In addition, the proposed fuzzy logic switching controller has reduced drastically the fuzzy rules due to the use of two‐dimensional (2D) membership functions. Particle swarm optimisation is used to tune the proposed 2D membership functions to guarantee smooth switching of the controllers while maintaining the desired constraints. The simulation results of both single‐machine and multi‐machine power systems confirm the effectiveness of the proposed PSS design.

26 July 2021 in Electronics
Verified
Journal Article
Open access
PDF file
Hilmy AwadHilmy Awad
Hilmy Awad
Ehab H. E. BayoumiEhab H. E. Bayoumi
Ehab H. E. Bayoumi
HSHisham M. Soliman
Hisham M. Soliman
Michele De SantisMichele De Santis
Michele De Santis
This paper introduces a new ellipsoidal-based tracker design to control a grid-connected hybrid direct current/alternating current (DC/AC) microgrid (MG). The proposed controller is robust against both parameters and load variations. The studied hybrid MG is modelled as a nonlinear dynamical system. A linearized model around an operating point is developed. The parameter changes are modelled as norm-bounded uncertainties. We apply the new extended version of the attractive (or invariant) ellipsoid for this tracking problem. Convex optimization is used to obtain the region’s minimal size where the tracking error between the state trajectories and the reference states converges. The sufficient conditions for stability are derived and solved based on linear matrix inequalities (LMIs). The proposed controller’s validity is shown via simulating the hybrid MG with various operational scenarios. In each scenario, the performance of the controller is compared with a recently proposed sliding mode controller. The comparison clearly illustrates the superiority of the developed controller in terms of transient and steady-state responses.

11 December 2008 in Electric Power Components and Systems
Verified
Journal Article
Closed access
HSHisham M. Soliman
Hisham M. Soliman
Ehab H. E. BayoumiEhab H. E. Bayoumi
Ehab H. E. Bayoumi
MHM. F. Hassan
M. F. Hassan
Power systems are subjected to severe repetitive oscillations that might cause generator shaft fatigue and, consequently, breakdown. In this article, we consider the problem of designing a power system stabilizer that alleviates generator shaft fatigue through the minimization of the maximum overshoot. Moreover, through our design, the levels of control signal, as well as controller parameters, have to be maintained within certain bounds imposed by physical and practical considerations. In this respect, a technique based on the particle swarm approach is proposed to identify the parameters of a fixed structure lead compensator through the solution of a min-max problem while satisfying systems constraints. To enhance the overall performance of the system under wide loading conditions, a set of operating points is considered within our approach. The proposed power system stabilizer is applied to a single-machine infinite-bus system at different loading conditions, and the results showed the effectiveness of the developed approach.

20 July 2016 in Transactions of the Institute of Measurement and Control
Verified
Journal Article
Closed access
ABAbdellah Benzaouia
Abdellah Benzaouia
HSHisham M. Soliman
Hisham M. Soliman
Ashraf SaleemAshraf Saleem
Ashraf Saleem
In this paper, the problem of robust stability and tracking of saturated control systems for buck DC-DC converters is considered. Linear Matrix Inequalities (LMIs) are used to insert the constraints in the design phase while imposing positivity in the closed-loop state. The control objective is to design a control law for the converter that limit duty ratio between 0 and 1. This will allow the system to switch between two topologies in the continuous conduction mode (CCM), to achieve a tracking reference condition. This has been developed using uncertain saturated control and regional pole placement techniques. The proposed controller is applied to a real DC-DC buck converter through a Hardware-In-the-Loop (HIL) test system. Experimental and simulation results show the effectiveness and the success of the proposed controller in tracking a reference voltage with limiting the duty ratio between 0 and 1. Results also show that the proposed controller performed better than the conventional one.

18 April 2012 in Journal of Vibration and Control
Verified
Journal Article
Closed access
HSHisham M. Soliman
Hisham M. Soliman
NBNaser S Bajabaa
Naser S Bajabaa
To alleviate mechanical parts fatigue and provide a comfortable ride for passengers, car mechanics require desired dynamic behavior of car suspensions. This paper suggests state feedback controllers that, with system uncertainties, guarantee the closed loop system satisfying the desired pole region, thus achieving satisfactory oscillation damping and settling time, and having the guaranteed cost performance simultaneously. A state feedback controller is applied to the design of an active suspension model for a quarter-car vehicle. The controller's parameters are obtained using the linear matrix inequalities optimization, also allowing considering the model uncertainty represented by a norm-bounded structure. Simulations are carried out taking into account the presence of uncertain parameters. The results are shown to be better than the classical linear quadratic regulator.