Tillmann Kerbel

Dr. Tillmann Kerbel


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
TKTillmann Kerbel
Tillmann Kerbel
LZLiliane Zillner
Liliane Zillner
MWMirjam G. Wild
Mirjam G. Wild
MHMichaela M. Hell
Michaela M. Hell
EKElmar W. Kuhn
Elmar W. Kuhn
MAMartin Andreas
Martin Andreas
Objectives: This study aims to review short- to intermediate-term outcomes after transapical transcatheter mitral valve replacement (TMVR) using the Tendyne valve system in patients with mitral annular calcification (MAC), including off-label use in severe MAC. Methods: This retrospective sub-analysis of the multicenter Tendyne European Experience (TENDER) registry included fifty-three MAC patients who underwent commercial Tendyne-TMVR in 15 European heart centers between 01/2020 and 06/2022. Patients were assigned to the mild (n = 16), moderate (n = 17), and severe MAC (n = 20) cohorts according to Guerrero’s MAC score. Additionally, the predictive value of detailed computed tomography-derived, quantitative, and qualitative MAC characteristics on clinical outcome was tested. Results: In this overall multimorbid patient population, predominantly treated for severe mitral regurgitation (MR), technical success rates were comparable among cohorts (mild MAC: 93.8% vs. moderate MAC: 88.2%vs. severe MAC: 95%, p = 0.720). Complete MR abolishment was achieved in 88.7% of patients, with no significant difference between cohorts in the incidence of residual MR >1+ (n = 1 in moderate MAC; p = 0.350) or paravalvular leakage >1+ (PVL; n = 2 in moderate MAC, p = 0.118) at discharge. All three in-hospital deaths occurred in patients with moderate MAC (p = 0.034). There were no significant differences in 1-year cardiovascular mortality (mild MAC: 23.1% vs. moderate MAC: 6.3% vs. severe MAC: 0%, p = 0.085) and overall mortality (mild MAC: 38.5% vs. moderate MAC: 43.8% vs. severe MAC: 18.8%, p = 0.291) between the cohorts, including in patients with off-label severe MAC. The rate of heart failure hospitalization at 1 year was significantly higher in the moderate MAC cohort (mild MAC: 10% vs. moderate MAC: 61.5%, severe MAC: 21.4%, p = 0.017). Further quantitative and qualitative MAC parameters showed no significant impact on 1-year survival or hemodynamic prosthetic performance. Conclusions: This MAC-focused analysis suggests that Valve-in-MAC using the Tendyne valve system is safe, technically feasible, and associated with satisfying hemodynamic and clinical outcomes, irrespective of MAC morphology.