The advances in micro- and nanofabrication technologies enable the preparation of increasingly smaller mechanical transducers capable of detecting the forces, motion, mechanical properties and masses that emerge in biomolecular interactions and fundamental biological processes. Thus, biosensors based on nanomechanical systems have gained considerable relevance in the last decade. This review provides insight into the mechanical phenomena that occur in suspended mechanical structures when either biological adsorption or interactions take place on their surface. This review guides the reader through the parameters that change as a consequence of biomolecular adsorption: mass, surface stress, effective Young's modulus and viscoelasticity. The mathematical background needed to correctly interpret the output signals from nanomechanical biosensors is also outlined here. Other practical issues reviewed are the immobilization of biomolecular receptors on the surface of nanomechanical systems and methods to attain that in large arrays of sensors. We then describe some relevant realizations of biosensor devices based on nanomechanical systems that harness some of the mechanical effects cited above. We finally discuss the intrinsic detection limits of the devices and the limitation that arises from non-specific adsorption.
Nanometer-size water bridges have been used to confine the oxidation of silicon surfaces with a noncontact atomic force microscope. The formation of a water bridge between two surfaces separated by a gap of a few nanometers is driven by the application of an electrical field. Once a liquid bridge is formed, its length and neck diameter can be modified by changing the tip-sample separation. The liquid bridge provides the ionic species and the spatial confinement to pattern Si(100) surfaces in noncontact force microscopy. The method is applied to write arrays of several thousands dots with a periodicity of 40 nm and an average width of 10 nm.
Local oxidation of silicon surfaces by atomic force microscopy is a very promising lithographic approach at nanometer scale. Here, we study the reproducibility, voltage dependence, and kinetics when the oxidation is performed by dynamic force microscopy modes. It is demonstrated that during the oxidation, tip and sample are separated by a gap of a few nanometers. The existence of a gap increases considerably the effective tip lifetime for performing lithography. A threshold voltage between the tip and the sample must be applied in order to begin the oxidation. The existence of a threshold voltage is attributed to the formation of a water bridge between tip and sample. It is also found that the oxidation kinetics is independent of the force microscopy mode used (contact or noncontact).