Fumiaki Funama

Dr. Fumiaki Funama

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2024 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
FFFumiaki Funama
Fumiaki Funama
SCSu-Ann Chong
Su-Ann Chong
MLMatthew Loyd
Matthew Loyd
KGKazimierz J. Gofron
Kazimierz J. Gofron
YZYuxuan Zhang
Yuxuan Zhang
FLFankang Li
Fankang Li
A scintillator-based Timepix3 (TPX3) detector was developed to resolve the high-frequency modulation of a neutron beam in both spatial and temporal domains, as required for neutron spin-echo experiments. In this system, light from a scintillator is manipulated with an optical lens and is intensified using an image intensifier, making it detectable with the TPX3 chip. Two different scintillators, namely, 6LiF:ZnS(Ag) and 6LiI:Eu, were investigated to achieve the high resolution needed for spin-echo modulated small-angle neutron scattering (SEMSANS) and modulation of intensity with zero effort (MIEZE). The methodology for conducting event-mode analysis is described, including the optimization of clustering parameters for both scintillators. The detector with both scintillators was characterized with respect to detection efficiency, spatial resolution, count rate, uniformity, and γ-sensitivity. The 6LiF:ZnS(Ag) scintillator-based detector achieved a spatial resolution of 200 μm and a count rate capability of 1.1 × 105 cps, while the 6LiI:Eu scintillator-based detector demonstrated a spatial resolution of 250 μm and a count rate capability exceeding 2.9 × 105 cps. Furthermore, high-frequency intensity modulations in both spatial and temporal domains were successfully observed, confirming the suitability of this detector for SEMSANS and MIEZE techniques, respectively.

25 September 2024 in Physical Review Applied
Verified
Journal Article
Closed access
JLJ.C. Leiner
J.C. Leiner
SKS.J. Kuhn
S.J. Kuhn
SMS. McKay
S. McKay
Johanna K. JochumJohanna K. Jochum
Johanna K. Jochum
FLF. Li
F. Li
RPR. Pynn
R. Pynn

1 July 2024 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
FFFumiaki Funama
Fumiaki Funama
CWCaitlyn M. Wolf
Caitlyn M. Wolf
KWKatie Weigandt
Katie Weigandt
JSJiazhou Shen
Jiazhou Shen
SPSteven R. Parnell
Steven R. Parnell
FLFankang Li
Fankang Li
We show the implementation of superconducting magnetic Wollaston prisms for spin echo small-angle neutron scattering. Two calibration methods for the spin echo length are presented: one utilizing spin echo modulated small-angle neutron scattering and the other based on the neutron refraction by quartz wedge crystals. Our experimental results with polystyrene nano-particle colloids showcase the system’s efficacy in measuring both dilute and concentrated colloidal systems. Additionally, investigations into the pore diameter and pitch of a nano-porous alumina membrane demonstrate its capability in analyzing nano-porous materials. Furthermore, we discuss potential optimizations to further extend the accessible spin echo length.

11 July 2024 in Journal of Applied Crystallography
Verified
Journal Article
Open access
PDF file
TJTim T. Jäger
Tim T. Jäger
ALAdrian S. Losko
Adrian S. Losko
AWAlexander Wolfertz
Alexander Wolfertz
SSSøren Schmidt
Søren Schmidt
MBMads Bertelsen
Mads Bertelsen
Sven C. VogelSven C. Vogel
Sven C. Vogel
Neutron diffraction beamlines have traditionally relied on deploying large detector arrays of 3 He tubes or neutron-sensitive scintillators coupled with photomultipliers to efficiently probe crystallographic and microstructure information of a given material. Given the large upfront cost of custom-made data acquisition systems and the recent scarcity of 3 He, new diffraction beamlines or upgrades to existing ones demand innovative approaches. This paper introduces a novel Timepix3-based event-mode imaging neutron diffraction detector system as well as first results of a silicon powder diffraction measurement made at the HIPPO neutron powder diffractometer at the Los Alamos Neutron Science Center. Notably, these initial measurements were conducted simultaneously with the 3 He array on HIPPO, enabling direct comparison. Data reduction for this type of data was implemented in the MAUD code, enabling Rietveld analysis. Results from the Timepix3-based setup and HIPPO were benchmarked against McStas simulations, showing good agreement for peak resolution. With further development, systems such as the one presented here may substantially reduce the cost of detector systems for new neutron instrumentation as well as for upgrades of existing beamlines.

1 September 2021 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
FFFumiaki Funama
Fumiaki Funama
STS. Tasaki
S. Tasaki
MHM. Hino
M. Hino
TOT. Oda
T. Oda
HEH. Endo
H. Endo

1 November 2024 in Review of Scientific Instruments
Verified
Journal Article
Closed access
SMSam McKay
Sam McKay
SKStephen J. Kuhn
Stephen J. Kuhn
JSJiazhou Shen
Jiazhou Shen
FLFankang Li
Fankang Li
JDJak Doskow
Jak Doskow
RPRoger Pynn
Roger Pynn
We present a resonant-mode, transverse-field, radio-frequency (rf) neutron spin flipper design that uses high-temperature superconducting films to ensure sharp transitions between uniform magnetic field regions. Resonant mode allows for low-power, high-frequency operation but requires strict homogeneity of the magnetic fields inside the device. This design was found to efficiently flip neutrons at 96.6 ± 0.6% at an effective frequency of 4 MHz in bootstrap configuration with a beam size of 2.4 × 2.5 cm2 and a wavelength of 0.4 nm. The high frequency and efficiency enable this device to perform high-resolution neutron spectroscopy with comparable performance with currently implemented rf flipper designs. The limitation of the maximum frequency was found due to the field homogeneity of the device. We numerically analyze the maximum possible efficiency of this design using a Bloch solver simulation with magnetic fields generated from finite-element simulations. We also discuss future improvements of the efficiency and frequency to the design based on the experimental and simulation results.