Adrian S. Losko

Adrian S. Losko

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
ALAdrian S. Losko
Adrian S. Losko
YHY. Han
Y. Han
BSB. Schillinger
B. Schillinger
ATA. Tartaglione
A. Tartaglione
MMM. Morgano
M. Morgano
MSM. Schulz
M. Schulz
Imaging using scintillators is a widespread and cost-effective approach in radiography. While different types of scintillator and sensor configurations exist, it can be stated that the detection efficiency and resolution of a scintillator-based system strongly depend on the scintillator material and its thickness. Recently developed event-driven detectors are capable of registering spots of light emitted by the scintillator after a particle interaction, allowing to reconstruct the Center-of-Mass of the interaction within the scintillator. This results in a more precise location of the event and therefore provides a pathway to overcome the scintillator thickness limitation and increase the effective spatial resolution of the system. Utilizing this principle, we present a detector capable of Time-of-Flight imaging with an adjustable field-of-view, ad-hoc binning and re-binning of data based on the requirements of the experiment including the possibility of particle discrimination via the analysis of the event shape in space and time. It is considered that this novel concept might replace regular cameras in neutron imaging detectors as it provides superior detection capabilities with the most recent results providing an increase by a factor 3 in image resolution and an increase by up to a factor of 7.5 in signal-to-noise for thermal neutron imaging.

8 September 2020 in ACS Nano
Verified
Journal Article
Closed access
KMKyle M. McCall
Kyle M. McCall
KSKostiantyn Sakhatskyi
Kostiantyn Sakhatskyi
ELEberhard Lehmann
Eberhard Lehmann
BWBernhard Walfort
Bernhard Walfort
ALAdrian S. Losko
Adrian S. Losko
MKMaksym V. Kovalenko
Maksym V. Kovalenko

22 April 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
ALAdrian S. Losko
Adrian S. Losko
SVS. C. Vogel
S. C. Vogel
Tools for three-dimensional elemental characterization are available on length scales ranging from individual atoms, using electrons as a probe, to micrometers with X-rays. However, for larger volumes up to millimeters or centimeters, quantitative measurements of elemental or isotope densities were hitherto only possible on the surface. Here, a novel quantitative elemental characterization method based on energy-resolved neutron imaging, utilizing the known neutron absorption cross sections with their ‘finger-print’ absorption resonance signatures, is demonstrated. Enabled by a pixilated time-of-flight neutron transmission detector installed at an intense short-pulsed spallation neutron source, for this demonstration 3.25 million state-of-the-art nuclear physics neutron transmission analyses were conducted to derive isotopic densities for five isotopes in 3D in a volume of 0.25 cm3. The tomographic reconstruction of the isotope densities provides elemental maps similar to X-ray microprobe maps for any cross section in the probed volume. The bulk isotopic density of a U-20Pu-10Zr-3Np-2Am nuclear transmutation fuel sample was measured, agrees well with mass-spectrometry and is evidence of the accuracy of the method.

13 February 2018 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
NBNicholas Borges
Nicholas Borges
ALAdrian S. Losko
Adrian S. Losko
Sven C. VogelSven C. Vogel
Sven C. Vogel
The energy-dependence of the neutron cross section provides vastly different contrast mechanisms than polychromatic neutron radiography if neutron energies can be selected for imaging applications. In recent years, energy-resolved neutron imaging (ERNI) with epi-thermal neutrons, utilizing neutron absorption resonances for contrast as well as for quantitative density measurements, was pioneered at the Flight Path 5 beam line at LANSCE and continues to be refined. Here we present event centroiding, i.e., the determination of the center-of-gravity of a detection event on an imaging detector to allow sub-pixel spatial resolution and apply it to the many frames collected for energy-resolved neutron imaging at a pulsed neutron source. While event centroiding was demonstrated at thermal neutron sources, it has not been applied to energy-resolved neutron imaging, where the energy resolution requires to be preserved, and we present a quantification of the possible resolution as a function of neutron energy. For the 55 μm pixel size of the detector used for this study, we found a resolution improvement from ~80 μm to ~22 μm using pixel centroiding while fully preserving the energy resolution.

1 December 2017 in Journal of Nuclear Materials
Verified
Journal Article
Closed access
SIS. Irukuvarghula
S. Irukuvarghula
BBB. Blamer
B. Blamer
SAS. Ahn
S. Ahn
SVS.C. Vogel
S.C. Vogel
ALAdrian S. Losko
Adrian S. Losko
SMS.M. McDeavitt
S.M. McDeavitt

1 April 2022 in Quantum Beam Science
Verified
Journal Article
Open access
PDF file
WCWilliam Chan
William Chan
Aaron CraftAaron Craft
Aaron Craft
Burkhard SchillingerBurkhard Schillinger
Burkhard Schillinger
JMJesus Mendoza
Jesus Mendoza
SCSteven Cool
Steven Cool
ALAdrian S. Losko
Adrian S. Losko
Fast neutrons enable a nondestructive examination of dense, large, and highly attenuating samples due to their lower interaction probability compared to thermal neutrons. However, this also creates a challenge in fast neutron imaging, as the thicker sensors necessary to detect fast neutrons degrade an image’s spatial resolution due to scattering within the sensor and the indeterminate depth of interaction in the sensor. This work explores the advantages of a fast neutron imaging screen with a layered polymer-phosphor screen approach as opposed to a mixed polymer-phosphor screen typically used in fast neutron imaging. Proton recoil is the primary conversion mechanism for fast neutron imaging. Simulations showed that the recoil proton range of typical fast neutrons is approximately 200 µm, however, tests at Idaho National Laboratory revealed that the light output of these screens increased at much greater polymer thicknesses. The NECTAR fast neutron beamline at FRM II was used to test the imaging performance of layered fast neutron imaging screens. Distinguishing between the fast-neutron and γ-ray signals is a major challenge in fast neutron imaging because all fast neutron sources also produce γ-rays. A relative comparison between a control plate and the fast neutron screen was made to distinguish between a γ-ray and fast neutron signals. MCNP modeling quantified the γ-ray and fast neutron contributions to the images measured at NECTAR, which were approximately a 75% γ-ray image.