Carlos Cunha

Carlos Cunha


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 June 2019 in Pharmaceuticals
Verified
Journal Article
Open access
PDF file
CCCarlos Cunha
Carlos Cunha
EREdson Silvio Batista Rodrigues
Edson Silvio Batista Rodrigues
MAMorgana Fernandes Alecrim
Morgana Fernandes Alecrim
Douglas Vieira ThomazDouglas Vieira Thomaz
Douglas Vieira Thomaz
IMIsaac Yves Lopes Macêdo
Isaac Yves Lopes Macêdo
EGEric Gil
Eric Gil
Diclofenac (DIC) is a non-steroidal anti-inflammatory drug of wide use around the world. Electroanalytical methods display a high analytical potential for application in pharmaceutical samples but the drawbacks concerning electrode fouling and reproducibility are of major concern. Henceforth, the aim of this work was to propose the use of alternative low-cost carbon black (CB) and ionic liquid (IL) matrix to modify the surface of pencil graphite electrodes (PGE) in order to quantify DIC in raw materials, intermediates, and final products, as well as in stability assays of tablets. The proposed method using CB+IL/PGE displayed good recovery (99.4%) as well as limits of detection (LOD) of 0.08 µmol L-1 and limits of quantification (LOQ) of 0.28 µmol L−1. CB+IL/PGE response was five times greater than the unmodified PGE. CB+IL-PGE stands as an interesting alternative for DIC assessment in different pharmaceutical samples.

5 October 2018 in Pharmaceuticals
Verified
Journal Article
Open access
PDF file
LGLuane Garcia
Luane Garcia
CCCarlos Cunha
Carlos Cunha
EMEmily Kussmaul Gonçalves Moreno
Emily Kussmaul Gonçalves Moreno
Douglas Vieira ThomazDouglas Vieira Thomaz
Douglas Vieira Thomaz
GLGermán Sanz Lobón
Germán Sanz Lobón
EGEric Gil
Eric Gil
Methyldopa is a catecholamine widely used in the treatment of mild to moderate hypertension whose determination in pharmaceutical formulae is of upmost importance for dose precision. Henceforth, a low-cost carbon paste electrode (CPE) consisting of graphite powder obtained from a crushed pencil stick was herein modified with nanostructured TiO2 (TiO2@CPE) aiming for the detection of methyldopa in pharmaceutical samples. The TiO2-modified graphite powder was characterized by scanning electron microscopy and X-ray diffraction, which demonstrated the oxide nanostructured morphology. Results evidenced that sensitivity was nonetheless increased due to electro-catalytic effects promoted by metal modification, and linear response obtained by differential pulse voltammetry for the determination of methyldopa (pH = 5.0) was between 10–180 μmol/L (Limit of Detection = 1 μmol/L) with the TiO2@CPE sensor. Furthermore, the constructed sensor was successfully applied in the detection of methyldopa in pharmaceutical formulations and excipients promoted no interference, that indicates that the sensor herein developed is a cheap, reliable, and useful strategy to detect methyldopa in pharmaceutical samples, and may also be applicable in determinations of similar compounds.

1 August 2019 in Pharmaceuticals
Verified
Journal Article
Open access
PDF file
EREdson Silvio Batista Rodrigues
Edson Silvio Batista Rodrigues
IMIsaac Yves Lopes Macêdo
Isaac Yves Lopes Macêdo
LLLarissa Lesley da Silva Lima
Larissa Lesley da Silva Lima
Douglas Vieira ThomazDouglas Vieira Thomaz
Douglas Vieira Thomaz
CCCarlos Cunha
Carlos Cunha
EGEric Gil
Eric Gil
This work details the study of the redox behavior of the drugs cyclobenzaprine (CBP), amitriptyline (AMP) and nortriptyline (NOR) through voltammetric methods and computational chemistry. Results obtained in this study show that the amine moiety of each compound is more likely to undergo oxidation at 1a at Ep1a ≈ 0.69, 0.79, 0.93 V (vs. Ag/AgCl/KClsat) for CBP, AMP and NOR, respectively. Moreover, CBP presented a second peak, 2a at Ep2a ≈ 0.98 V (vs. Ag/AgCl/KClsat) at pH 7.0. Furthermore, the electronic structure calculation results corroborate the electrochemical assays regarding the HOMO energies of the lowest energy conformers of each molecule. The mechanism for each anodic process is proposed according to electroanalytical and computational chemistry findings, which show evidence that the methods herein employed may be a valuable alternative to study the redox behavior of structurally similar drugs.

17 April 2020 in Pharmaceuticals
Verified
Journal Article
Open access
PDF file
MCMurilo Ferreira de Carvalho
Murilo Ferreira de Carvalho
LGLuane Garcia
Luane Garcia
IMIsaac Yves Lopes Macêdo
Isaac Yves Lopes Macêdo
RMRicardo Neves Marreto
Ricardo Neves Marreto
MTMayk Teles
Mayk Teles
EGEric Gil
Eric Gil
Carvedilol (CRV) is a non-selective blocker of α and β adrenergic receptors, which has been extensively used for the treatment of hypertension and congestive heart failure. Owing to its poor biopharmaceutical properties, CRV has been incorporated into different types of drug delivery systems and this necessitates the importance of investigating their compatibility and stability. In this sense, we have investigated the applicability of several electroanalytical tools to assess CRV compatibility with lipid excipients. Voltammetric and electrochemical impedance spectroscopy techniques were used to evaluate the redox behavior of CRV and lipid excipients. Results showed that Plurol® isostearic, liquid excipient, and stearic acid presented the greatest anode peak potential variation, and these were considered suitable excipients for CRV formulation. CRV showed the highest stability at room temperature and at 50 °C when mixed with stearic acid (7% w/w). The results also provided evidence that electrochemical methods might be feasible to complement standard stability/compatibility studies related to redox reactions.