Pietro Dioni

Dr. Pietro Dioni

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 October 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
AGAlessandro Grandi
Alessandro Grandi
AMAndrea Melloni
Andrea Melloni
PDPietro Dioni
Pietro Dioni
SBStefano Bonardelli
Stefano Bonardelli
LBLuca Bertoglio
Luca Bertoglio
Endovascular repair of thoracoabdominal aortic aneurysms (TAAAs) requires multidisciplinary expertise to minimize mortality and disabling complications. Despite satisfactory outcomes with this approach being common knowledge, extensive aortic coverage occurring in fenestrated/branched endovascular aortic repair (F/B-EVAR) carries a non-negligible risk of spinal cord ischemia (SCI). Recently, many authors have proposed different endovascular strategies to mitigate the risk of SCI; however, the real effectiveness of these maneuvers is not universally recognized due to a lack of standardized protocols among individual centers. Several adjuncts have been proposed to obtain staged occlusion of segmental aortic branches to promote spinal cord preconditioning. These strategies include proximal thoracic aortic repair (PTAR), temporary aneurysm sac perfusion (TASP), and minimally invasive staged segmental artery coil embolization (MIS2ACE). The present paper aims to provide an overview of the most advanced staging strategies used in high-volume aortic centers, pointing out that it takes meticulous preoperative planning to face every clinical scenario.

Verified
Journal Article
Open access
PDF file
AMAndrea Melloni
Andrea Melloni
Mario D’OriaMario D’Oria
Mario D’Oria
PDPietro Dioni
Pietro Dioni
DODeborah Ongaro
Deborah Ongaro
GBGiovanni Badalamenti
Giovanni Badalamenti
LBLuca Bertoglio
Luca Bertoglio
Vascular plugs are an evolving family of vessel occluders providing a single-device embolization system for large, high-flow arteries. Nitinol mesh plugs and polytetrafluoroethylene membrane plugs are available in different configurations and sizes to occlude arteries from 3 to 20 mm in diameter. Possible applications during complex endovascular aortic procedures are aortic branch embolization to prevent endoleak or to gain an adequate landing zone, directional branch occlusion, and false lumen embolization in aortic dissection. Plugs are delivered through catheters or introducers, and their technical and clinical results are comparable to those of coil embolization. Plugs are more accurate than coils as repositionable devices, less prone to migration, and have fewer blooming artifacts on postoperative computed tomography imaging. Their main drawback is the need for larger delivery systems. This narrative review describes up-to-date techniques and technology for plug embolization in complex aortic repair.

27 February 2026 in JMIR Research Protocols
Verified
Journal Article
Open access
PDPietro Dioni
Pietro Dioni
AWAnders Wanhainen
Anders Wanhainen
JBJacob William Budtz-Lilly
Jacob William Budtz-Lilly
NDNuno Dias
Nuno Dias
TBTab Bonny
Tab Bonny
EIEMBRACE study investigator
EMBRACE study investigator
Background: Covered stents commercially available are frequently used off-label in conjunction with fenestrated and branched aortic stent grafts, but there is a lack of dedicated devices. Objective: This study aims to assess the safety and mid-term clinical performance of a new dedicated covered stent, the GORE VIABAHN VBX Balloon Expandable Endoprosthesis (VBX stent graft), when used as a bridging stent with branched and fenestrated aortic endografts in treating complex abdominal aortic and thoraco-abdominal aneurysms. Methods: A retrospective, multicenter, single-arm study in the European Union (ClinicalTrials.gov NCT05143138) enrolled patients treated with the VBX stent graft as a bridging stent in branched endovascular repair (BEVAR) and fenestrated endovascular repair (FEVAR) to allow endovascular aneurysm repair between January 2017 and December 2021. Up to 15 sites in Europe were required to enroll a minimum of 220 patients. Patients’ medical records were reviewed by the investigator, and specific data were collected ambispectively for up to 5 years of follow-up from the index procedure. The primary end point is target vessel patency (patient level) through 12 months. The registry was designed to statistically test target vessel patency at 12 months in both FEVAR and BEVAR populations. The hypothesis will be tested separately in the 2 cohorts (fenestrated or branched endovascular repair), using patients with core laboratory imaging results available annually through 5 years. The binomial exact test will be used with a 1-sided 2.5% level of significance to test the null hypothesis. Results: In total, 259 patients were retrospectively enrolled for a prospective follow-up of 5 years: 136 patients (n=99, 72.8% male; mean age 73, SD 8.9 y) in the BEVAR cohort, 92 patients (n=80, 87.0% male, mean age 72.7, SD 8.1 y) in the FEVAR cohort, and 31 patients (n=17, 54.8% male, mean age 70.9, SD 9.4 y) in the mixed fenestrated or branched endovascular repair cohort. Overall, 662 target vessels were stented with the investigational covered stents: 163 (24.6%) celiac trunk, 192 (29.0%) superior mesenteric artery, and 307 (46.4%) renal arteries. The VBX stent grafts were paired with branches in 451 (68.1%) cases or fenestrations in 211 (31.9%) cases among all Cook Medical stent graft cases. The 1-year results will be published in the fourth quarter of 2025, and the 5-year follow-up results will be analyzed by mid-year 2028. Conclusions: This study will investigate the VBX stent graft performance in combination with fenestrated and branched aortic grafts to corroborate its use in complex aortic endovascular procedures and support the modification of current device instructions for use.

4 September 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
AGAlessandro Grandi
Alessandro Grandi
AMAndrea Melloni
Andrea Melloni
PDPietro Dioni
Pietro Dioni
SBStefano Bonardelli
Stefano Bonardelli
LBLuca Bertoglio
Luca Bertoglio
Endovascular repair of thoracoabdominal aortic aneurysms (TAAAs) requires multidisciplinary expertise to minimize mortality and disabling complications. Despite satisfactory outcomes with this approach being common knowledge, extensive aortic coverage occurring in fenestrated/branched endovascular aortic repair (F/B-EVAR) carries a non-negligible risk of spinal cord ischemia (SCI). Recently, many authors have proposed different endovascular strategies to mitigate the risk of SCI; however, the real effectiveness of these maneuvers is not universally recognized due to a lack of standardized protocols among individual centers. Several adjuncts have been proposed to obtain staged occlusion of segmental aortic branches to promote spinal cord preconditioning. These strategies include proximal thoracic aortic repair (PTAR), temporary aneurysm sac perfusion (TASP), and minimally invasive staged segmental artery coil embolization (MIS2ACE). The present paper aims to provide an overview of the most advanced staging strategies used in high-volume aortic centers, pointing out that it takes meticulous preoperative planning to face every clinical scenario.

19 May 2026 in Reports
Verified
Journal Article
Open access
PDF file
PDPietro Dioni
Pietro Dioni
FCFrancesco Colamaria
Francesco Colamaria
AGAlessandro Grandi
Alessandro Grandi
Gabriele PiffarettiGabriele Piffaretti
Gabriele Piffaretti
SBStefano Bonardelli
Stefano Bonardelli
LBLuca Bertoglio
Luca Bertoglio
Background and Clinical Significance: Treatment options for chronic type B aortic dissections (TBADs) remain a topic of ongoing debate. Patients with post-dissection thoracoabdominal aortic aneurysms (PD-TAAAs) are typically younger than those with degenerative TAAAs, and their aortas undergo continuous remodeling over their lifetime. Fenestrated/branched endovascular aortic repair (F/B-EVAR) has shown promising results, but it can be challenged by the presence of a narrow true lumen, which hinders navigation and deployment of bridging components. Moreover, the presence of patent segmental arteries originating from the false lumen may prevent aneurysm shrinkage due to persistent flow, which may also result in insufficient spinal cord protection strategies and an increased risk of spinal cord ischemia. Consequently, multiple endovascular interventions are often necessary to address the persistent anatomical changes in these patients. Case Presentation: We present the case of a patient affected by a post-dissecting TAAA who underwent multiple open and endovascular treatment attempts. The presence of prior multiple laparotomies discouraged a new open surgical repair, while the hypertrophic segmental arteries and the presence of a narrow true lumen made standard F/B-EVAR unfeasible. The patient was successfully treated using a combination of different adjunctive advanced endovascular techniques, including minimally invasive segmental artery coil embolization (MiSACE) as a spinal cord preconditioning strategy and prevention of type II endoleak. Moreover, transcatheter electrosurgical septotomy (TES) was used to create a single aortic channel in the presence of a narrow true lumen, which allowed the deployment of a multifeatured, custom-made branched endograft. Conclusions: Endovascular repair of post-dissection TAAAs requires a thorough understanding of advanced endovascular adjuncts, which are often combined to overcome the complex anatomical challenges inherent to this disease. Although encouraging results have been reported, both segmental artery embolization for the indications described here and TES warrant further evaluation in prospective multicenter studies to confirm their safety and efficacy.

27 September 2025 in JACC: Case Reports
Verified
Journal Article
Open access
PDPietro Dioni
Pietro Dioni
AVApollonia Verrengia
Apollonia Verrengia
AMAndrea Melloni
Andrea Melloni
FNFranco Nodari
Franco Nodari
SBStefano Bonardelli
Stefano Bonardelli
LBLuca Bertoglio
Luca Bertoglio
To present the surgical management of a 22-year-old patient with midaortic syndrome, symptomatic for claudication and renovascular hypertension, with infected aortic and renal stent grafts. Procedures were performed as follows: 1) right renal autotransplantation through a transperitoneal approach and midline abdominal incision; 2) thoracotomy with left visceral rotation and visceral vessel exposure; 3) left-heart bypass and "debranch-first" technique, with warm blood perfusion for the splanchnic vessels and cold Custodiol solution for renal perfusion; 4) aortic replacement with a tubular xenopericardium graft; and 5) separate reattachment of visceral vessel to the main tubular graft. Recurrent infections of the xenopericardium graft, kidney parenchyma loss, and major complications such as spinal cord ischemia, represent potential pitfalls to this procedure. Kidney autotransplantation allows right renal-infected stent graft removal before in situ thoracoabdominal reconstruction through left thoracoabdominal access, preserving renal function against renovascular hypertension.