Large-scale and widely distributed air-conditioning (AC) loads can be aggregated into load-type Virtual Power Plants (VPPs) to participate in peak-shaving ancillary services, thereby improving the allocation of demand-side electricity resources. However, current AC aggregation methods primarily focus on meeting peak-shaving instructions and generally employ fixed incentive pricing and proportional capacity allocation, making it difficult to balance user revenue and satisfaction and thereby constraining the flexibility of VPP demand-side regulation. This paper proposes a unified incentive-based demand response scheduling framework for both fixed- and variable-frequency AC loads across industrial, commercial, and residential scenarios. Based on the Equivalent Thermal Parameter model, AC loads are classified into curtailable and shiftable types, with their adjustable boundaries characterized by a Time-of-Use (TOU) elasticity-based interaction willingness model and a fuzzy load transfer rate model, respectively. A three-objective optimization model is established to maximize user revenue while minimizing user dissatisfaction and scheduling error, with incentive pricing and capacity allocation jointly optimized via Non-dominated Sorting Genetic Algorithm III (NSGA-III). Case studies are conducted on a load-type VPP covering three scenarios, namely a large industrial zone, a commercial zone, and a residential zone, under weekday and non-weekday TOU tariffs and three representative 1 h peak-shaving periods. Compared with a fixed-pricing benchmark, the proposed strategy increases total user revenue by 9.4% to 11.4% and reduces weighted average dissatisfaction by 0.27 to 1.92%. The case study results demonstrate that the proposed method can improve the trade-off between user revenue and satisfaction.
Transient instability during the low-voltage ride-through (LVRT) recovery of permanent magnet synchronous generator (PMSG) wind turbines is strongly influenced by weak-grid interactions, while the quantitative relationship among grid strength, control parameters, and recovery performance remains insufficiently understood. This paper develops a small-signal transient recovery characteristic matrix for a grid-connected PMSG system by incorporating the dynamic interactions among the phase-locked loop (PLL), inner current loop, DC-link voltage loop, and grid-side inductance. Dominant-mode and root-locus analyses are employed to investigate how variations in the short-circuit ratio (SCR) affect dominant eigenvalue trajectories and the sensitivities of six PI control parameters. Based on the identified dynamic mechanisms, an SCR-adaptive sensitivity-guided particle swarm optimization (SG-PSO) method is proposed for coordinated PI parameter tuning. The proposed approach introduces SCR-dependent damping constraints and physical feasibility constraints, while normalized real-part eigenvalue sensitivities are utilized to guide the optimization process toward the most influential control parameters. Compa-ra-tive simulation results demonstrate that, under SCR = 1.5, SG-PSO reduces the point of common coupling (PCC) voltage overshoot to 1.4% and shortens the recovery time to 58 ms, outperforming conventional PSO and OOBO-PI methods. Under SCR = 2.5, the recovery time is further reduced to 46 ms while maintaining a low overshoot of 0.9%. Additional robustness tests under parameter uncertainties and fault-condition variations confirm the effectiveness and adaptability of the proposed method. The results indicate that the pro-posed SG-PSO framework provides an effective solution for enhancing LVRT recovery performance of PMSG wind turbines operating in weak-grid environments.
Virtual power plants (VPPs) aggregate flexible resources, such as distributed photovoltaics (PV), energy storage, and flexible loads, to provide substantial reserve capacity for grid operation. However, the combined effects of renewable energy output uncertainty, load forecast errors, and user-bounded rationality responses lead to significant errors in traditional deterministic VPP reserve assessment methods, severely affecting the balance between system supply and demand. To address this challenge, this paper proposes a credible reserve assessment method that accounts for user-bounded rationality. First, thermodynamic models with on–off constraints for air conditioning loads, energy feasible region, and power constraint models for electric vehicles (EVs) and energy storage systems (ESSs), as well as PV forecast error models are established to characterize physical reserve boundaries. Second, prospect theory is introduced to describe user-bounded rationality and a logit-based response probability model is developed. Monte Carlo sampling and kernel density estimation are employed to derive credible reserve sets under different confidence levels, achieving a probabilistic quantification of VPP reserve capacity distribution. Case studies demonstrate that the proposed method accurately characterizes the probabilistic distribution characteristics of VPP reserve provision under multiple uncertainties, providing comprehensive and reliable assessment information for power dispatching agencies.
Distributed photovoltaic (PV) systems play an important role in supporting low-carbon and sustainable distribution network development; however, their high-penetration integration can cause nodal overvoltage, as midday PV generation often exceeds local demand and net reverse power flows accumulate along feeders. Existing studies mainly focus on technical mitigation, while entity-level responsibility quantification and its translation into differentiated mitigation tasks remain insufficiently explored. This paper proposes an overvoltage mitigation method integrating Shapley-value-based responsibility quantification with active–passive-responsibility-driven task allocation. Reverse power flow quotas are determined using the Technique for Order Preference by Similarity to Ideal Solution (TOPSIS) by considering the differentiated impacts of PV entities on power flow distribution and nodal voltage response. The load-weighted voltage deviation index is adopted as the coalition cost function, and the Shapley value is used to quantify each entity’s overvoltage responsibility share. Active and passive responsibilities are characterized through the net reverse power ratio and reactive power–voltage sensitivity, respectively, establishing a mapping mechanism from responsibility shares to active power curtailment and reactive power regulation tasks. A multi-objective optimization model that jointly considers line losses, PV curtailment, fairness deviation, and task-allocation deviation is constructed and solved using the whale optimization algorithm. Case studies on the IEEE 33-bus system show that the proposed method reduces the maximum network voltage from 1.25 pu to 1.052 pu and eliminates all overvoltage violations. Compared with a cluster-based scheme, the 24-h cumulative line loss is reduced by 30.6%, and the fairness deviation is significantly lowered, thereby supporting the sustainable, economical, and equitable operation of distribution networks with high distributed PV penetration.
Transient instability during the low-voltage ride-through (LVRT) recovery of permanent magnet synchronous generator (PMSG) wind turbines is strongly influenced by weak-grid interactions, while the quantitative relationship among grid strength, control parameters, and recovery performance remains insufficiently understood. This paper develops a small-signal transient recovery characteristic matrix for a grid-connected PMSG system by incorporating the dynamic interactions among the phase-locked loop (PLL), inner current loop, DC-link voltage loop, and grid-side inductance. Dominant-mode and root-locus analyses are employed to investigate how variations in the short-circuit ratio (SCR) affect dominant eigenvalue trajectories and the sensitivities of six PI control parameters. Based on the identified dynamic mechanisms, an SCR-adaptive sensitivity-guided particle swarm optimization (SG-PSO) method is proposed for coordinated PI parameter tuning. The proposed approach introduces SCR-dependent damping constraints and physical feasibility constraints, while normalized real-part eigenvalue sensitivities are utilized to guide the optimization process toward the most influential control parameters. Comparative simulation results demonstrate that, under SCR = 1.5, SG-PSO reduces the point of common coupling (PCC) voltage overshoot to 1.4% and shortens the recovery time to 58 ms, achieving better transient recovery indices than conventional PSO and OOBO-PI under the same simulation and constraint settings. Under SCR = 2.5, the recovery time is further reduced to 46 ms while maintaining a low overshoot of 0.9%. Additional robustness tests under parameter uncertainties and fault-condition variations further support the effectiveness and adaptability of the proposed method. The results indicate that the proposed SG-PSO framework provides an effective solution for enhancing LVRT recovery performance of PMSG wind turbines operating in weak-grid environments.
This paper proposes a short-term photovoltaic (PV) power prediction method that integrates aerosol optical feature mining with a dual-channel attention mechanism to address the complex non-linear attenuation effects of atmospheric aerosols and the limitations of existing models in handling sudden meteorological changes and aerosol evolution. Using the optical properties of aerosols and clouds (OPAC) database, a high-dimensional aerosol optical feature set is constructed, which is subsequently optimized using the minimum redundancy maximum relevance (mRMR) algorithm. The prediction scenarios are categorized into polluted and clean regimes through K-means clustering. A dual-channel encoder–decoder network, combining bidirectional long short-term memory (BiLSTM) and iTransformer, is developed to capture high-frequency meteorological volatility and low-frequency aerosol evolution. A bidirectional cross-attention mechanism enables deep feature interaction between the optical and meteorological channels. The method is validated using in situ measurements from a PV station in Hebei, China, along with aerosol data from the Copernicus Atmosphere Monitoring Service (CAMS) and meteorological data from the ECMWF Reanalysis v5 (ERA5). Experimental results demonstrate an average reduction of approximately 29.83% in mean absolute error (MAE) on polluted days and 15.22% on clean days. Interpretability analysis reveals distinct physical mechanisms driving the predictions, emphasizing the role of extinction on polluted days and scattering on clean days.