Traditional virtual synchronous generator (VSG) control in photovoltaic–storage systems struggles with severe dynamic deterioration under high-impedance weak grid conditions. Through small-signal modeling, this paper analytically reveals that increased grid inductance forces the system’s dominant poles to migrate significantly toward the real axis, inducing a critical “overdamped hysteresis” that degrades transient tracking speed and oscillation attenuation. To break these physical constraints, an improved exponential synergistic adaptive control strategy is proposed. By establishing a synergistic optimization mechanism between the virtual inertia and damping coefficients via a square-root coupled exponential function, the proposed method achieves precise multi-parameter coordination. During the initial phase of disturbances, it triggers an explosive parameter surge to provide “stiff” transient support, strictly limiting frequency deviations and the rate of change of frequency (RoCoF). During the recovery phase, it drives a precipitous parameter decay to actively neutralize the overdamped coupling effect, forcibly pulling the migrated poles back to the ideal underdamped region. Rigorous switching-model simulations demonstrate that, compared to conventional fixed-parameter and power function-based adaptive methods, the proposed synergistic strategy significantly improves transient performance. Quantitatively, during load steps, it restricts the frequency nadir to 49.85 Hz (compared to 49.73 Hz for fixed parameters). During extreme grid stiffness transitions (SCR drops), it completely eliminates active power tracking hysteresis by reducing the settling time to just 0.26 s and aggressively clamps AC overcurrent peaks from 38 A down to 31 A. Supported by coordinated PV–storage energy management, the proposed method offers a highly robust grid-forming framework for renewable-dominated weak power grids. Supported by coordinated PV–storage energy management, the proposed method offers a highly robust grid-forming framework for renewable-dominated weak power grids.
Transient instability during the low-voltage ride-through (LVRT) recovery of permanent magnet synchronous generator (PMSG) wind turbines is strongly influenced by weak-grid interactions, while the quantitative relationship among grid strength, control parameters, and recovery performance remains insufficiently understood. This paper develops a small-signal transient recovery characteristic matrix for a grid-connected PMSG system by incorporating the dynamic interactions among the phase-locked loop (PLL), inner current loop, DC-link voltage loop, and grid-side inductance. Dominant-mode and root-locus analyses are employed to investigate how variations in the short-circuit ratio (SCR) affect dominant eigenvalue trajectories and the sensitivities of six PI control parameters. Based on the identified dynamic mechanisms, an SCR-adaptive sensitivity-guided particle swarm optimization (SG-PSO) method is proposed for coordinated PI parameter tuning. The proposed approach introduces SCR-dependent damping constraints and physical feasibility constraints, while normalized real-part eigenvalue sensitivities are utilized to guide the optimization process toward the most influential control parameters. Compa-ra-tive simulation results demonstrate that, under SCR = 1.5, SG-PSO reduces the point of common coupling (PCC) voltage overshoot to 1.4% and shortens the recovery time to 58 ms, outperforming conventional PSO and OOBO-PI methods. Under SCR = 2.5, the recovery time is further reduced to 46 ms while maintaining a low overshoot of 0.9%. Additional robustness tests under parameter uncertainties and fault-condition variations confirm the effectiveness and adaptability of the proposed method. The results indicate that the pro-posed SG-PSO framework provides an effective solution for enhancing LVRT recovery performance of PMSG wind turbines operating in weak-grid environments.
Photovoltaic (PV)-storage systems operating in weak grids are affected by high grid impedance, transient voltage disturbances, and measurement noise, which can degrade frequency regulation, increase converter current stress, and impose high-frequency current fluctuations on the battery. To address these issues, this paper proposes a multi-timescale transient-state sensing and signal-processing framework for grid-forming PV-hybrid storage systems. The proposed framework combines three coordinated functions. First, a frequency-domain HESS power-decoupling mechanism separates high-frequency transient power components and assigns them to the supercapacitor, while the battery mainly handles low-frequency energy variations. Second, a voltage-deviation-driven adaptive virtual inductance is introduced to increase the equivalent output impedance during voltage-sag events and reduce transient inrush current. Third, a noise-resilient frequency sensing strategy based on a filtered frequency derivative and a dead-band for false-trigger suppression is developed to reduce noise-induced false triggering in adaptive inertia and damping control. Comparative simulations indicate that under the tested weak-grid conditions, the proposed method reduces the transient inrush-current peak by 53.2%, decreases the maximum dynamic frequency deviation by approximately 75%, and improves the active-power regulation speed by more than 50%. These results indicate that the proposed sensing-oriented framework can improve transient response while reducing converter and battery current stress in PV-storage systems connected to high-impedance grids.
Transient instability during the low-voltage ride-through (LVRT) recovery of permanent magnet synchronous generator (PMSG) wind turbines is strongly influenced by weak-grid interactions, while the quantitative relationship among grid strength, control parameters, and recovery performance remains insufficiently understood. This paper develops a small-signal transient recovery characteristic matrix for a grid-connected PMSG system by incorporating the dynamic interactions among the phase-locked loop (PLL), inner current loop, DC-link voltage loop, and grid-side inductance. Dominant-mode and root-locus analyses are employed to investigate how variations in the short-circuit ratio (SCR) affect dominant eigenvalue trajectories and the sensitivities of six PI control parameters. Based on the identified dynamic mechanisms, an SCR-adaptive sensitivity-guided particle swarm optimization (SG-PSO) method is proposed for coordinated PI parameter tuning. The proposed approach introduces SCR-dependent damping constraints and physical feasibility constraints, while normalized real-part eigenvalue sensitivities are utilized to guide the optimization process toward the most influential control parameters. Comparative simulation results demonstrate that, under SCR = 1.5, SG-PSO reduces the point of common coupling (PCC) voltage overshoot to 1.4% and shortens the recovery time to 58 ms, achieving better transient recovery indices than conventional PSO and OOBO-PI under the same simulation and constraint settings. Under SCR = 2.5, the recovery time is further reduced to 46 ms while maintaining a low overshoot of 0.9%. Additional robustness tests under parameter uncertainties and fault-condition variations further support the effectiveness and adaptability of the proposed method. The results indicate that the proposed SG-PSO framework provides an effective solution for enhancing LVRT recovery performance of PMSG wind turbines operating in weak-grid environments.