Anton Nosenko

Dr. Anton Nosenko

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 March 2015 in Discover Nano
Verified
Journal Article
Open access
PDF file
ANAnton Nosenko
Anton Nosenko
TMTaras Mika
Taras Mika
OROlexandr Rudenko
Olexandr Rudenko
YYYevhenii Yarmoshchuk
Yevhenii Yarmoshchuk
VNViktor Nosenko
Viktor Nosenko
Amorphous Fe73B7Si16Nb3Cu1 ribbon was crystallized rapidly by electric current heating under simultaneously applied tensile stress along the ribbon axis. As a result, strong transverse magnetic anisotropy was induced in the ribbon. Dynamic magnetic properties of the ribbons rapidly heated either under the tensile stress or without tensile stress were measured using toroidal cores. Optimal electric current heating regime that provides maximum improvement of the initial magnetic permeability and core loss was determined. Tensile stress increase from 0 to 180 MPa was shown to result in the decrease of the initial magnetic permeability down to 400 and core loss at frequencies from 0.4 to 200 kHz. Comparative analysis of magnetic properties of the cut core (with non-magnetic gap) and the cores heated under tensile stress was carried out. The magnetic properties of the latter cores are advantageous for manufacturing the reactors and linear chokes of switch-mode power supplies.

30 June 2019 in Materials
Verified
Journal Article
Open access
PDF file
MNMichał Nowicki
Michał Nowicki
PGPiotr Gazda
Piotr Gazda
Roman SzewczykRoman Szewczyk
Roman Szewczyk
AMAndriy Marusenkov
Andriy Marusenkov
ANAnton Nosenko
Anton Nosenko
VKVasyl Kyrylchuk
Vasyl Kyrylchuk
The significant strain dependence of the hysteretic Giant Magnetoimpedance (GMI) effect in a Co67Fe3Cr3B12Si15 amorphous alloy in a low magnetizing field is presented. A simplistic test stand capable of continuous measurements of GMI characteristics under the influence of strain is detailed. Based on the results, a stress-impedance (SI) sensor is proposed, with a gauge factor similar to semiconductor strain gauges but more robust. An effective method of minimizing external magnetic field influence on the SI effect is given.

24 October 2018 in Materials
Verified
Journal Article
Open access
PDF file
MNMichał Nowicki
Michał Nowicki
Roman SzewczykRoman Szewczyk
Roman Szewczyk
TCTomasz Charubin
Tomasz Charubin
AMAndriy Marusenkov
Andriy Marusenkov
ANAnton Nosenko
Anton Nosenko
VKVasyl Kyrylchuk
Vasyl Kyrylchuk
This paper presents investigation results regarding the Jiles-Atherton-based hysteresis loop modeling of ultra-high permeability amorphous alloy MELTA® MM-5Co. The measurement stand is capable of accurately measuring minor and major hysteresis loops for such a material together with exemplary measurement results. The main source of the measurement error is highlighted, which includes the Earth’s field influence. The results of hysteresis loop modeling with the original Jiles-Atherton model and with two of its modifications are given. In all cases, the parameters of the Jiles-Atherton model were identified in two-step identification on the basis of a differential evolution optimization algorithm. The results indicate that both the original and modified Jiles-Atherton models are suitable for modeling the ultra-soft amorphous alloy. However, the hysteresis model’s parameters vary significantly.

5 February 2016 in Discover Nano
Verified
Journal Article
Open access
PDF file
ANAnton Nosenko
Anton Nosenko
OROlexandr Rudenko
Olexandr Rudenko
TMTaras Mika
Taras Mika
IYIgor Yevlash
Igor Yevlash
OSOlexandr Semyrga
Olexandr Semyrga
VNViktor Nosenko
Viktor Nosenko
The comparative analysis of magnetic properties of cut cores made of nanocrystalline Fe73Nb3Cu1B7Si16 alloy ribbon and cores made of the same ribbon with preliminary tension-induced transverse magnetic anisotropy was carried out. The possibility of improving magnetic properties of cut cores, decreasing loss, and increasing DC bias immunity of reversible magnetic permeability is presented. The influence of induced magnetic anisotropy on DC bias immunity of reversible magnetic permeability was investigated. The advantages and disadvantages of new cores (made of ribbon heated under tensile stress) over cut ones were determined.

1 December 2018 in Journal of Automation, Mobile Robotics and Intelligent Systems
Verified
Journal Article
Closed access
TCTomasz Charubin
Tomasz Charubin
MNMichał Nowicki
Michał Nowicki
AMAndriy Marusenkov
Andriy Marusenkov
Roman SzewczykRoman Szewczyk
Roman Szewczyk
ANAnton Nosenko
Anton Nosenko
VKVasyl Kyrylchuk
Vasyl Kyrylchuk

26 April 2017 in Discover Nano
Verified
Journal Article
Open access
PDF file
ANAnton Nosenko
Anton Nosenko
TMTaras Mika
Taras Mika
OSOlexandr Semyrga
Olexandr Semyrga
ANAnton Nosenko
Anton Nosenko
The influence of winding-induced mechanical stresses on the magnetic anisotropy and core loss in toroidal cores made of Fe73Cu1Nb3Si16B7 ribbon is studied. The ribbon for the cores was rapidly pre-heated under tensile stress up to 120 MPa. It was found that magnetic characteristics of the material (magnetic anisotropy energy and the core loss) can be controlled by varying the tensile stress during the preliminary rapid heating of the ribbon. It was shown that with reducing core diameter, the magnetic anisotropy energy and core loss significantly increase. However, relatively high winding-induced core loss in small cores can be significantly reduced by increasing tensile stresses applied to the ribbon during pre-heating.