Tomasz Charubin

Tomasz Charubin

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 October 2018 in Materials
Verified
Journal Article
Open access
PDF file
MNMichał Nowicki
Michał Nowicki
Roman SzewczykRoman Szewczyk
Roman Szewczyk
TCTomasz Charubin
Tomasz Charubin
AMAndriy Marusenkov
Andriy Marusenkov
ANAnton Nosenko
Anton Nosenko
VKVasyl Kyrylchuk
Vasyl Kyrylchuk
This paper presents investigation results regarding the Jiles-Atherton-based hysteresis loop modeling of ultra-high permeability amorphous alloy MELTA® MM-5Co. The measurement stand is capable of accurately measuring minor and major hysteresis loops for such a material together with exemplary measurement results. The main source of the measurement error is highlighted, which includes the Earth’s field influence. The results of hysteresis loop modeling with the original Jiles-Atherton model and with two of its modifications are given. In all cases, the parameters of the Jiles-Atherton model were identified in two-step identification on the basis of a differential evolution optimization algorithm. The results indicate that both the original and modified Jiles-Atherton models are suitable for modeling the ultra-soft amorphous alloy. However, the hysteresis model’s parameters vary significantly.

2 May 2023 in Journal of Magnetism and Magnetic Materials
Verified
Journal Article
Open access
PRPaweł Robert Rękas
Paweł Robert Rękas
MNMichał Nowicki
Michał Nowicki
PGPiotr Gazda
Piotr Gazda
TCTomasz Charubin
Tomasz Charubin
Tadeusz SzumiataTadeusz Szumiata
Tadeusz Szumiata
Roman SzewczykRoman Szewczyk
Roman Szewczyk

10 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
PGPrzemysław Grenda
Przemysław Grenda
MKMonika Kutyła
Monika Kutyła
MNMichał Nowicki
Michał Nowicki
TCTomasz Charubin
Tomasz Charubin
In this paper, the design and investigation of an innovative force sensor, based on the Villari effect, is presented. The sensor was built from electrical steel, in a pressductor pattern, but working in bending load mode. The results of the experimental research allowed for the evaluation of transducer’s performance, mitigation of measurement hysteresis, and optimization of its functional parameters. Several issues have been examined, among them the selection of supply and measured signals, the measured values’ impact on measurement hysteresis, harmonic analysis, and the selection of proper current waveforms and frequencies. The proposed sensor is robust, made from inexpensive materials, and has high sensitivity, as compared to other magnetoelastic sensors. It has much higher stress sensitivity than other magnetoelastic sensors due to deformation mode. Based on the tests, its measuring range can be defined as 0.5–5 N with a near-linear characteristic, SNR of 46 dB, and 0.11 N uncertainty.

4 February 2016
Verified
Book Chapter
Closed access
PDF file
MUMichał Urbański
Michał Urbański
TCTomasz Charubin
Tomasz Charubin
PRPaweł Rozum
Paweł Rozum
MNMichał Nowicki
Michał Nowicki
Roman SzewczykRoman Szewczyk
Roman Szewczyk

11 February 2019 in Materials
Verified
Journal Article
Open access
PDF file
TCTomasz Charubin
Tomasz Charubin
MNMichał Nowicki
Michał Nowicki
Roman SzewczykRoman Szewczyk
Roman Szewczyk
The Matteucci effect (ME) is one of the lesser-known magnetomechanical effects and is most prominent in bistable amorphous wires. It has some experimental applications—Matteucci effect-based magnetic field sensors are very easy to produce and have inherently linear, hybrid analog/digital output signal. The effect is still poorly understood, however, and although it relies on torsion of the wire to manifest, there is no available model, or much experimental data, which would quantitatively connect the ME with the sample twist. In this paper, experimental characteristics of ME signal parameters dependence on torsion in Co-based amorphous bistable wire are presented. The results hint at possible applications, such as rotation or critical current sensors, as well as the necessity of torsion control in the development of ME magnetic field sensors.

1 August 2018 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
PDF file
TCTomasz Charubin
Tomasz Charubin
MNMichał Nowicki
Michał Nowicki
Roman SzewczykRoman Szewczyk
Roman Szewczyk
DC magnetic field sensor similar to fluxgates utilizing Matteucci Effect was proposed previously. As these types of sensors depend on measuring the second harmonic of the signal, a spectral analysis of Matteucci effect signal was measured. Results indicate that each harmonic is periodical with the increase of DC magnetic field and the period decreases with the harmonic number, making higher harmonics better suitable for lower measurement ranges. Thus, measurement range of the proposed sensor can be selected by tuning to proper harmonic frequency. Moreover, there is no difference in signal amplitude between odd and even harmonics, so any of them could be used for signal extraction.