M. Inês G. S. Almeida

Dr. M. Inês G. S. Almeida

School of Chemistry, University of Melbourne, Parkville, Melbourne, Victoria 3010, Australia

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2021 in Waste Management
Verified
Journal Article
Closed access
BHBosirul Hoque
Bosirul Hoque
SKSpas D. Kolev
Spas D. Kolev
RCRobert W. Cattrall
Robert W. Cattrall
TGThiruvancheril G. Gopakumar
Thiruvancheril G. Gopakumar
M. Inês G. S. AlmeidaM. Inês G. S. Almeida
M. Inês G. S. Almeida

1 June 2019 in Food Chemistry
Verified
Journal Article
Closed access
RVRuben Vera
Ruben Vera
Yanlin ZhangYanlin Zhang
Yanlin Zhang
Clàudia FontàsClàudia Fontàs
Clàudia Fontàs
M. Inês G. S. AlmeidaM. Inês G. S. Almeida
M. Inês G. S. Almeida
Enriqueta AnticóEnriqueta Anticó
Enriqueta Anticó
Spas Dimitrov KolevSpas Dimitrov Kolev
Spas Dimitrov Kolev

1 December 2020 in Environmental Pollution
Verified
Journal Article
Closed access
LŠLenka O’cOnnor Šraj
Lenka O’cOnnor Šraj
M. Inês G. S. AlmeidaM. Inês G. S. Almeida
M. Inês G. S. Almeida
SSSimon M. Sharp
Simon M. Sharp
IMIan D. McKelvie
Ian D. McKelvie
RMRichard Morrison
Richard Morrison
SKSpas D. Kolev
Spas D. Kolev

31 October 2020 in Molecules
Verified
Journal Article
Open access
PDF file
TRTânia Ribas
Tânia Ribas
CCCharles F. Croft
Charles F. Croft
M. Inês G. S. AlmeidaM. Inês G. S. Almeida
M. Inês G. S. Almeida
Raquel B.R. MesquitaRaquel B.R. Mesquita
Raquel B.R. Mesquita
Spas Dimitrov KolevSpas Dimitrov Kolev
Spas Dimitrov Kolev
António RangelAntónio Rangel
António Rangel
A bi-parametric sequential injection method for the determination of copper(II) and zinc(II) when present together in aqueous samples was developed. This was achieved by using a non-specific colorimetric reagent (4-(2-pyridylazo)resorcinol, PAR) together with two ion-exchange polymeric materials to discriminate between the two metal ions. A polymer inclusion membrane (PIM) and a chelating resin (Chelex 100) were the chosen materials to retain zinc(II) and copper(II), respectively. The influence of the flow system parameters, such as composition of the reagent solutions, flow rates and standard/sample volume, on the method sensitivity were studied. The interference of several common metal ions was assessed, and no significant interferences were observed (<10% signal deviation). The limits of detection were 3.1 and 5.6 µg L−1 for copper(II) and zinc(II), respectively; the dynamic working range was from 10 to 40 µg L−1 for both analytes. The newly developed sequential injection analysis (SIA) system was applied to natural waters and soil leachates, and the results were in agreement with those obtained with the reference procedure.