Hanane Zejli

Dr. Hanane Zejli


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 March 2007 in Talanta
Verified
Journal Article
Closed access
HZHanane Zejli
Hanane Zejli
JCJ.L. Hidalgo-Hidalgo de Cisneros
J.L. Hidalgo-Hidalgo de Cisneros
INI. Naranjo-Rodriguez
I. Naranjo-Rodriguez
KTK.R. Temsamani
K.R. Temsamani

10 September 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RBRachid El brychy
Rachid El brychy
MRMoutie mohamed Rguiti
Moutie mohamed Rguiti
NRNadia Rhazzane
Nadia Rhazzane
MMMoulay Driss Mellaoui
Moulay Driss Mellaoui
KAKhalid ABBICHE
Khalid ABBICHE
HZHanane Zejli
Hanane Zejli
Today, organic wastes (paints, pigments, etc.) are considered to be a major concern for the pollution of aqueous environments. Therefore, it is essential to find new methods to solve this problem. This research was conducted to study the use of electrochemical processes to remove organic pollutants (e.g., crystal violet (CV)) from aqueous solutions. The galvanostatic electrolysis of CV by the use of Ti/Pt/SnO2 anode, were conducted in an electrochemical cell with 100 mL of solution using Na2SO4 and NaCl as supporting electrolyte, the effect of the important electrochemical parameters: current density (20–60 mA cm−2), CV concentration (10–50 mg L−1), sodium chloride concentration (0.01–0.1 g L−1) and initial pH (2 to 10) on the efficiency of the electrochemical process was evaluated and optimized. The electrochemical treatment process of CV was monitored by the UV-visible spectrometry and the chemical oxygen demand (COD). After only 120 min, in a 0.01 mol L−1 NaCl solution with a current density of 50 mA cm−2 and a pH value of 7 containing 10 mg L−1 CV, the CV removal efficiency can reach 100%, the COD removal efficiency is up to 80%. The process can therefore be considered as a suitable process for removing CV from coloured wastewater in the textile industries.

30 September 2006 in Electrochemistry Communications
Verified
Journal Article
Closed access
HZHanane Zejli
Hanane Zejli
KTKhalid R. Temsamani
Khalid R. Temsamani
JCJosé Luis Hidalgo-Hidalgo de Cisneros
José Luis Hidalgo-Hidalgo de Cisneros
INIgnacio Naranjo-Rodriguez
Ignacio Naranjo-Rodriguez
PSPatrick Sharrock
Patrick Sharrock

1 October 2007 in Analytical Letters
Verified
Journal Article
Closed access
HZHanane Zejli
Hanane Zejli
JCJ. L. Hidalgo‐Hidalgo de Cisneros
J. L. Hidalgo‐Hidalgo de Cisneros
INI. Naranjo‐Rodriguez
I. Naranjo‐Rodriguez
HEH. Elbouhouti
H. Elbouhouti
MCM. Choukairi
M. Choukairi
KTK. R. Temsamani
K. R. Temsamani
Successful applications of different analytical procedures to determine quantitatively mercury in aqueous media can be found in recent literature. Fundamentally it has made use of Cold Vapour Atomic Absorption Spectrometry (CV‐AAS), X‐Ray Fluorescence or UV Spectrophotometry, Inductively Coupled Plasma Atomic Emission Spectrometry (ICP‐AES), or Inductively Coupled Plasma Mass Spectrometry (ICP‐MS), which are the techniques commonly used for trace measurement of heavy metal in the laboratory. In this paper a new and alternative methodology to determine quantitatively mercury in aqueous media is reported. A kryptofix carbon‐paste electrode has been used to determine voltammetrically mercury. The detection limit for mercury was evaluated to be 0.12 µg/l.

1 May 2006 in Analytical Letters
Verified
Journal Article
Closed access
HZHanane Zejli
Hanane Zejli
JCJ. L. Hidalgo‐Hidalgo de Cisneros
J. L. Hidalgo‐Hidalgo de Cisneros
INI. Naranjo‐Rodriguez
I. Naranjo‐Rodriguez
KTKhalid Temsamani
Khalid Temsamani
A solid Sonogel‐Carbon electrode was modified for the determination of Hg (II) in industrial waste water. 3‐Methylthiophene (3MT), pyrrol, poly‐3‐methylthiophene (P3MT), polypyrrol, and C18 were used for the chemical modification. The obtained composite electrodes were tested for their response to Hg(II); the best results were observed for the 3MT monomer modification with a detection limit of 10−2 mg · l−1 and 3 weeks lifetime of use. A linear relationship between anodic peak height and concentration inside the range of 0.07–0.42 mg · l−1 was obtained. A study of interferences due to other heavy metal is also included.

15 March 2010 in Talanta
Verified
Journal Article
Closed access
HZHanane Zejli
Hanane Zejli
JCJose Luis Hidalgo-Hidalgo de Cisneros
Jose Luis Hidalgo-Hidalgo de Cisneros
INIgnacio Naranjo-Rodríguez
Ignacio Naranjo-Rodríguez
KTKhalid Riffi Temsamani
Khalid Riffi Temsamani
Jean Louis MartyJean Louis Marty
Jean Louis Marty