Purpose: The glomerular filtration rate (GFR) is essential for carboplatin chemotherapy dosing; however, the best method to estimate GFR in patients with cancer is unknown. We identify the most accurate and least biased method.Methods: We obtained data on age, sex, height, weight, serum creatinine concentrations, and results for GFR from chromium-51 (51Cr) EDTA excretion measurements (51Cr-EDTA GFR) from white patients ≥ 18 years of age with histologically confirmed cancer diagnoses at the Cambridge University Hospital NHS Trust, United Kingdom. We developed a new multivariable linear model for GFR using statistical regression analysis.51Cr-EDTA GFR was compared with the estimated GFR (eGFR) from seven published models and our new model, using the statistics root-mean-squared-error (RMSE) and median residual and on an internal and external validation data set. We performed a comparison of carboplatin dosing accuracy on the basis of an absolute percentage error > 20%.Results: Between August 2006 and January 2013, data from 2,471 patients were obtained. The new model improved the eGFR accuracy (RMSE, 15.00 mL/min; 95% CI, 14.12 to 16.00 mL/min) compared with all published models. Body surface area (BSA)–adjusted chronic kidney disease epidemiology (CKD-EPI) was the most accurate published model for eGFR (RMSE, 16.30 mL/min; 95% CI, 15.34 to 17.38 mL/min) for the internal validation set. Importantly, the new model reduced the fraction of patients with a carboplatin dose absolute percentage error > 20% to 14.17% in contrast to 18.62% for the BSA-adjusted CKD-EPI and 25.51% for the Cockcroft-Gault formula. The results were externally validated.Conclusion: In a large data set from patients with cancer, BSA-adjusted CKD-EPI is the most accurate published model to predict GFR. The new model improves this estimation and may present a new standard of care.
Background The COVID-19 crisis forced hospitals in the UK dramatically to reduce outpatient activity. To provide continuity of care and to assist patients reluctant or unable to leave their homes, video consultations were rapidly implemented across routine and emergency ophthalmology services. Objective To describe the deployment and scaling to a large volume of teleophthalmology using a video consultation platform ‘Attend Anywhere’ in Moorfields Eye Hospital’s accident and emergency (A&E) department (London, UK). Method Patient satisfaction, waiting time, consultation duration, outcome and management were audited following the launch of the new virtual A&E service. Results In the 12 days following the service launch, 331 patients were seen by video consultation. 78.6% of patients (n=260) were determined not to need hospital A&E review and were managed with advice (n=126), remote prescription (n=57), general practitioner referral (n=27), direct referral to hospital subspecialty services (n=26) or diversion to a local eye unit (n=24). Mean patient satisfaction was 4.9 of 5.0 (n=62). The mean consultation duration was 12 min (range 5–31 min) and the wait time was 6 min (range 0–37 min). Conclusion Video consultations showed greater than expected usefulness in the remote management of eye disease and supported a substantial reduction in the number of people visiting the hospital.
Objective Though one of the most common surgeries, there is limited information on variability of practices in cataract surgeries. ‘Eyefficiency’ is a cataract surgical services auditing tool to help global units improve their surgical productivity and reduce their costs, waste generation and carbon footprint. The aim of the present research is to identify variability and efficiency opportunities in cataract surgical practices globally. Methods and Analysis 9 global cataract surgical facilities used the Eyefficiency tool to collect facility-level data (staffing, pathway steps, costs of supplies and energy use), and live time-and-motion data. A point person from each site gathered and reported data on 1 week or 30 consecutive cataract surgeries. Environmental life cycle assessment and descriptive statistics were used to quantify productivity, costs and carbon footprint. The main outcomes were estimates of productivity, costs, greenhouse gas emissions, and solid waste generation per-case at each site. Results Nine participating sites recorded 475 cataract extractions (a mix of phacoemulsification and manual small incision). Cases per hour ranged from 1.7 to 4.48 at single-bed sites and 1.47 to 4.25 at dual-bed sites. Average per-case expenditures ranged between £31.55 and £399.34, with a majority of costs attributable to medical equipment and supplies. Average solid waste ranged between 0.19 kg and 4.27 kg per phacoemulsification, and greenhouse gases ranged from 41 kg carbon dioxide equivalents (CO2e) to 130 kg CO2e per phacoemulsification. Conclusion Results demonstrate the global diversity of cataract surgical services and non-clinical metrics. Eyefficiency supports local decision-making for resource efficiency and could help identify regional or global best practices for optimising productivity, costs and environmental impact of cataract surgery.
The need for social distancing midst the COVID-19 pandemic has forced ophthalmologists to innovate with telemedicine. The novel process of triaging emergency ophthalmology patients via videoconsultations should reduce hospital attendances. However, the safety profile of such services were unknown. in this retrospective cohort study, we reviewed case notes of 404 adults who used our videoconsultation service from 20/04/2020 to 03/05/2020. We compared these to 451 patient who attended eye casualty in person at the same time who were deemed not to require same day ophthalmic examination. patients seen by videoconsultations tended to be younger (Median = 43 years, Inter-quartile range = 27 vs Median= 49 years, Inter-quartile range = 28)'. More males used the face-to-face triage (55%) while more females used videoconsultation (54%)%. Fewer patients seen by videoconsultations required specialist review compared to face-face triage [X2 (1, N = 854) = 128.02, p<0.001)]. 35.5% of the patients initially seen by videoconsultation had unplanned reattendance within 1 month, compared to 15.7% in the group initially seen in person. X2 (1, N = 234) = 7.31, p = 0.007). The rate of actual harm was no different (at 0% for each method), with perfect inter-grader correlation when graded independently by two senior ophthalmologists. 97% of patients seen on the video platform surveyed were satisfied with their care. we demonstrate comparable patient safety of videoconsultations at one-month follow-up to in person review. The service is acceptable to patients and reduces the risk of COVID-19 transmission. We propose that videoconsultations are effective and desirable as a tool for triage in ophthalmology. the research supported by the National Institute for Health Research (NIHR) Biomedical Research Centre based at Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology who fund PT and DS's time to conduct research. The views expressed are those of the author(s) and not necessarily those of the NHS, the NIHR or the Department of Health.