Cerium and its derivatives have been used as remedies for wounds since the early 20th century. Cerium nitrate has attracted most attention in the treatment of deep burns, followed later by reports of its antimicrobial properties. Its ability to mimic and replace calcium is presumed to be a major mechanism of its beneficial action. However, despite some encouraging results, the overall data are somewhat confusing with seemingly the same compounds yielding opposing results. Despite this, cerium nitrate is currently used in wound treatment in combination with silver sulfadiazine as Flammacérium. Cerium oxide, especially in nanoparticle form (Nanoceria), has lately captured much interest due to its antibacterial properties mediated via oxidative stress, leading to an increase of published reports. The properties of Nanoceria depend on the synthesis method, their shape and size. Recently, the green synthesis route has gained a lot of interest as an alternative environmentally friendly method, resulting in production of effective antimicrobial and antifungal nanoparticles. Unfortunately, as is the case with antibiotics, emerging bacterial resistance against cerium-derived nanoparticles is a growing concern, especially in the case of bacterial biofilm. However, diverse strategies resulting from better understanding of the biology of cerium are promising. The aim of this paper is to present the progress to date in the use of cerium compounds as antimicrobials in clinical applications (in particular wound healing) and to provide an overview of the mechanisms of action of cerium at both the cellular and molecular level.
Purpose: The aim of this study was to investigate soft-tissue attachment to different metal, ceramic, and polymer implant surfaces using an inflamed, three-dimensional (3D), tissue-engineered, human oral mucosal model, as well as multiple-endpoint qualitative and quantitative biological approaches. Methods: Normal human oral fibroblasts, OKF6/TERT-2 keratinocytes and THP-1 monocytes were cultured, and full-thickness, 3D oral mucosal models were engineered inside tissue culture inserts. Sand-blasted and acid-etched (SLA) and machined (M) titanium–zirconium alloy (TiZr; commercially known as Roxolid; Institut Straumann AG, Switzerland), ceramic (ZrO2), and polyether ether ketone (PEEK) rods (Ø 4 mm × 8 mm) were inserted into the center of tissue-engineered oral mucosa following a Ø 4mm punch biopsy. Inflammation was simulated with addition of the lipopolysaccharide (LPS) of Escherichia coli (E. coli) and tumor necrosis factor (TNF)-alpha to the culture medium. Implant soft-tissue attachment was assessed using histology, an implant pull-test with PrestoBlue assay, and scanning electron microscopy (SEM). Results: Inflamed, full-thickness, 3D human oral mucosal models with inserted implants were successfully engineered and histologically characterized. The implant pull-test with PrestoBlue assay showed higher viability of the tissue that remained attached to the TiZr-SLA surface compared to the other test groups. This difference was statistically significant (p < 0.05). SEM analysis showed evidence of epithelial cell attachment on different implant surfaces. Conclusions: The inflamed, 3D, oral mucosal model has the potential to be used as a suitable in vitro test system for visualization and quantification of implant soft-tissue attachment. The results of our study indicate greater soft tissue attachment to TiZr-SLA compared to TiZr-M, ceramic, and PEEK surfaces.
Background: The aim of this study was to investigate and visualize the anti-inflammatory and anti-bacterial effects of different oral care products using an infected and inflamed 3D tissue-engineered gingival mucosal model. Methods: A 3D full-thickness oral mucosal model was engineered inside tissue culture inserts using collagen hydrogels populated with human gingival fibroblasts and THP-1 monocytes and layered with oral epithelial cell lines. Oral saliva bacteria were cultured and added to the surface of the models and inflammation was further simulated with lipopolysaccharide (LPS) of Escherichia coli. The 3D models were exposed to three different types of toothpastes, a chlorhexidine antiseptic mouthwash, different antibiotics, and a mechanical rinse with phosphate-buffered saline (PBS) prior to biological evaluation using the PrestoBlue tissue viability assay, histology, optical coherence tomography (OCT), confocal microscopy, and measurement of the release of the inflammatory markers IL-1β, IL-6, and IL-8 with ELISA. Results: Multiple-endpoint analyses of the infected oral mucosal models treated with different anti-bacterial agents showed consistent outcomes in terms of tissue viability, histology, OCT, and confocal microscopy findings. In terms of anti-inflammatory testings, the positive control group showed the highest level of inflammation compared with all other groups. Depending on the anti-bacterial and anti-inflammatory potential of the test groups, different levels of inflammation were observed in the test groups. Conclusions: The inflamed 3D oral mucosal model developed in this study has the potential to be used as a suitable in vitro model for testing the biocompatibility, anti-inflammatory, and anti-bacterial properties of oral care products including mouthwashes and toothpastes. The results of this study indicate that the chlorhexidine mouthwash has both anti-bacterial and cytotoxic effects on the 3D oral mucosal model. Hyaluronic-acid-containing toothpaste has significant anti-bacterial and anti-inflammatory effects on the 3D oral mucosal model.
Cervical tissue hydration level is one of the most important parameters to monitor in the early diagnosis of preterm birth. Electrical-impedance-spectroscopy-based techniques are often used, but they suffer from limited accuracy. Open microwave coaxial probes have been widely used as a broadband dielectric characterization technique for human tissue samples due to their versatility, but with limited accuracy due to their nonresonant nature. In this work, a resonant microwave open coaxial probe with multiple harmonic resonances is proposed as a sensing platform for tissue-hydration-level monitoring. The mechanical design was analyzed and verified by finite-element full 3D electromagnetic simulation and experiments. Dominant sources of errors and the ways to mitigate them were discussed. In vitro experiments were carried out on human cervix samples to verify the precision and accuracy by comparing the results to a commercial skin-hydration sensor. The proposed sensor shows mean fractional frequency shift of (3.3 ± 0.3) × 10−4 per unit % over the entire data. This translates into an absolute frequency shift ( of 252 ± 23 kHz/%, 455 ± 41 kHz/%, and 647 ± 57 kHz/% at second, fourth, and sixth harmonic resonance, respectively.
Background/Objectives: The formation of a soft tissue seal through mucosal integration around dental implants is critical for potentially achieving long-term peri-implant health and clinical success. Understanding how different implant and abutment surfaces interact with individual layers of the oral mucosa remains limited. This study aimed to compare the differential attachment of tissue-engineered oral epithelium, connective tissue, and full-thickness human oral mucosa to various implant and abutment materials and surface topographies. Methods: Sand-blasted, large-grit, acid-etched (TiZr-SLA), machined TiZr (TiZr-M), machined zirconia (ZrO2-M), polished zirconia (ZrO2-P), and machined PEEK rods, along with commercially available titanium and ZrO2 healing abutments, were inserted into 3D oral mucosal models following a 4-mm punch biopsy. Inflammation was induced using Escherichia coli lipopolysaccharide. Analyses included histology, PrestoBlue viability assay, scanning electron microscopy, and ELISA quantification of cytokines IL-1β, IL-6, and IL-8. Results: Epithelial attachment was greater on TiZr-SLA, ZrO2-P, and PEEK-M (p < 0.05 and p < 0.01) surfaces compared with TiZr-M and ZrO2-M. TiZr-SLA exhibited the highest connective tissue attachment (p < 0.05). Commercial titanium and ZrO2 healing abutments demonstrated the highest post-pull PrestoBlue viability and overall soft tissue attachment. SEM confirmed cell retention on all implant surfaces. Elevated IL-1β levels were detected in models exposed to ZrO2-M and PEEK-M, whereas IL-6 and IL-8 levels were not influenced by any material or surface topography. Conclusions: In vitro epithelial and connective tissue responses are influenced by implant material, surface topography, and design. Rough TiZr-SLA surfaces promote superior connective tissue attachment, while smooth commercial abutments support optimal overall soft tissue integration. These findings highlight the importance of surface engineering in preclinical optimization of peri-implant soft tissue attachment.