This study aims to investigate the influence of substituting silica fume with fly ash in fly ash-based geopolymer mortars. The replacement ratios of silica fume were 2%, 4%, 6%, 8%, and 10% on a mass basis with fly ash. The NaOH was used as an alkali activator. The produced geopolymer mortars were heat cured at a temperature of 75 °C for various durations: 24 and 48 h. The workability, unit weight, flexural strength, and compressive strength were conducted on geopolymer mortars. Selected mortars underwent abrasion and elevated temperature tests (300 °C, 600 °C, and 900 °C) based on their mechanical and compressive strength performance. Additionally, thermogravimetric analysis (TGA) and field emission scanning electron microscope (FESEM) imaging for microstructure and life cycle assessment (LCA) analysis for environmental performance were conducted. According to test results, optimum replacement ratio of silica fume (%2–4) with fly ash showed better performance than that reference geopolymer mortar in terms of strength properties and environmental impact categories of global warming potential, terrestrial ecotoxicity and abiotic depletion. These results indicate that silica fume replacement within this range enhances geopolymerization while maintaining structural integrity.
20 March 2024 in Iranian Journal of Science and Technology, Transactions of Civil Engineering
DOI: 10.7764/RDLC.18.2.386 Behaviour of construction materials i.e. steel, concrete and mortar under elevated temperature is important. In the study, the variations in mass loss, and strengths of polypropylene fiber reinforced mortar subjected to elevated temperatures were examined. Mortar was made with CEM I 42.5R Portland cement, monofilament polypropylene fiber, fine aggregate and drinkable water. The sand-cement and water-cement ratio were chosen 3:1 and 1:2 for all mixtures, respectively. Mixes containing 0, 0.1, 0.2 and 0.3% polypropylene fiber in volume of solid matter of mixture were prepared. Mortars were exposed to 100, 200, 400, 600 and 800°C temperatures and cooled down 23±2°C in air and water. There was a difference between the temperatures at which the important reductions observed for flexural tensile and compressive strength. Significant reduction was observed at 400°C for compressive strength and while it was 200°C for flexural strength. No difference was observed between air cooling and water cooling regimes up to 600°C; however, at 800°C the residual compressive and flexural strength of water cooled mortar was about 40% of the air cooled mortar. Mortar containing polypropylene fiber presented better behaviour to elevated temperature in terms of relative residual strengths up to 400°C.