Background: Artificial intelligence has revolutionized the field of dentistry. This systematic review evaluated the clinical performance of artificial intelligence (AI)-assisted cephalometric tracing compared with manual or expert digital tracing. Methods: We searched the PubMed/MEDLINE, Scopus, and Web of Science databases from inception to 20 May 2026. Studies directly comparing AI-assisted tracing with manual or expert digital tracing of the same lateral cephalograms and reporting at least one clinically relevant cephalometric outcome were included in the review. Two authors independently screened records. Risk of bias was assessed using an adapted QUADAS-2 framework. A quantitative meta-analysis was planned but not performed. Findings were synthesised narratively by measurement, platform, and workflow, with reporting informed by the Synthesis Without Meta-analysis (SWiM) guideline. Results: Twenty studies were included. Direct AI-versus-reference ICCs were reported in more than three studies, but their formulations and reference procedures varied. Small average differences sometimes coexisted with wide individual limits of agreement. The numerical evidence did not establish a consistent ranking of SNA, SNB, and ANB. Conclusions: AI-assisted tracing may be useful as a clinician-verified adjunct, but its performance depends on the measurement, platform, and workflow. The evidence does not establish uniform clinical interchangeability with manual or expert digital tracing.
Background: The foramen of Vesalius (FV; also known as the sphenoidal emissary foramen (SEF) or foramen venosum) is an inconstant skull-base foramen located near the foramen ovale. Its recognition may be relevant to percutaneous trigeminal procedures. Methods: This systematic review was registered in INPLASY (INOLASY2025100037; 11 October 2025) and conducted in accordance with PRISMA 2020. We searched PubMed, Scopus, and Web of Science from inception until December 2025 for English-language studies reporting the prevalence and/or morphometry of the foramen of Vesalius using cone-beam computed tomography (CBCT). Five reviewers screened and extracted data; prevalence studies were assessed for risk of bias using the Joanna Briggs Institute checklist. A random-effects meta-analysis of logit-transformed proportions was applied when ≥3 studies reported comparable prevalence outcomes. Results: Five retrospective CBCT studies (n = 1567) met the inclusion criteria. The prevalence of FV ranged from 28.1% (89/317; 95% CI 23.4–33.3) to 73.1% (190/260; 95% CI 67.4–78.1) throughout the cohorts. The total prevalence was 50.6% (95% CI 36.1–65.1), with significant variability (I2 = 96.8%) and a broad 95% prediction interval (19.5–81.3). The documented FV–FO distances were typically a few millimeters (about 2–5 mm), whereas the FV–foramen spinosum (FS) distances varied from approximately 11 to 14 mm, contingent upon the cohort and measuring technique employed. Conclusions: FV is frequently observable on CBCT when the skull base is within the field of view; nevertheless, current prevalence estimates lack precision because of the limited number of five retrospective investigations, which are inconsistent and clinic-based. Standardized definitions and reporting for CBCT, together with population-based cohorts, are crucial for improving clinically applicable prevalence and morphometric reference data.
Background: This study aimed to assess cone-beam computed tomography (CBCT) knowledge, adherence to justification criteria, field-of-view (FOV) selection practices, and awareness of radiation protection guidelines among dental practitioners in the Asir region. In Saudi Arabia, the Saudi Food and Drug Authority (SFDA) and the Nuclear and Radiological Regulatory Commission are the regulatory bodies responsible for radiation protection and the safe use of dental imaging; limited awareness of their roles may undermine regulatory compliance and patient safety. Accordingly, the specific objectives of this study were: (i) to assess knowledge of CBCT justification criteria and radiation-dose magnitudes; (ii) to evaluate adherence to the requirement for a prior 2D radiograph; (iii) to examine FOV selection across standardized clinical vignettes; (iv) to explore factors associated with knowledge scores; and (v) to identify perceived barriers to appropriate CBCT prescribing. Methods: A cross-sectional descriptive-analytical survey targeted 73 dental practitioners in Abha, Saudi Arabia. A validated 30-item questionnaire was distributed via Google Forms using snowball convenience sampling. The effective target population comprised dental practitioners and interns working in Abha during the study period. Because recruitment used open snowball distribution without a fixed sampling frame, a formal response rate could not be calculated. Results: The mean knowledge score was 5.47/10 (standard deviation: 1.86). Item-level correct rates were 82.2% for caries detection, 80.8% for the requirement for a prior 2D radiograph, and 58.9% for paediatric CBCT justification. FOV selection across four clinical vignettes ranged from 27.4% to 68.5% correct, with the lower-left-molar implant vignette showing the lowest rate (27.4%) and the six-unit anterior implant bridge vignette also poorly answered (37.0%), reflecting a frequent tendency to select an inappropriately large FOV. Guideline awareness was low: 65.8% were completely unaware of the Safety and Efficacy of a New and Emerging Dental X-ray Modality Computed Tomography (SEDENTEX CT) 2012 guidelines, while 54.8% did not know that the American Dental Association publishes specific radiation guidelines. In an exploratory multivariable model, no factor was a statistically significant predictor of the knowledge score; formal CBCT training showed a small, non-significant association (B = 0.585; 95% confidence interval [−0.27, 1.44]; p = 0.175). Conclusions: In this preliminary survey, CBCT knowledge among dental practitioners in Abha was moderate but suboptimal, with almost half of respondents scoring below the satisfactory threshold and with significant gaps in FOV optimisation and guideline awareness. Given the small, non-probability sample, these findings should be regarded as preliminary and hypothesis-generating.
Background: Accurate knowledge of the pterygopalatine fossa (PPF) and the greater palatine canal/foramen (GPC/GPF) is clinically important for administering anesthesia through the canals and for planning surgical access to the posterior maxilla. Cone-beam computed tomography (CBCT) enables evaluation of anatomic structures of interest in individual patients when two-dimensional imaging methods are inadequate. Methods: This cross-sectional study retrospectively analyzed 150 CBCT datasets from residents of Abha city in the Asir region of Saudi Arabia who visited a dental hospital from November 2025 to February 2026; of these, 65 datasets were included. Bilateral measurements of the PPF-GPC complex and the anteroposterior (AP) position of the GPF were taken; subject-level means were used to avoid non-independence. Multivariate models adjusted for age and sex were fitted. Curvature was assessed using a cluster logistic model. Results: The mean length of the PPF-GPC complex was 33.12 ± 3.07 mm (P5-P95 interval, 28.91–39.50). After adjusting for age and sex, males had a longer pathway (+2.25 mm; 95% confidence interval [CI], 0.35–4.15; p = 0.020); pathway length decreased slightly with increasing age (−0.38 mm per decade; 95% CI, −0.73 to −0.03; p = 0.034). The mean distance from the ANS to the GPF was 47.28 ± 3.58 mm and increased with age by 0.67 mm per decade (95% CI, 0.23–1.11; p = 0.003). Curved canals accounted for 56.2% of the sides examined. No significant association was observed between sex and either curvature status or side. Conclusions: In this population, the length of the pathway from the palate to the PPF and the AP location of the GPF showed clinically relevant variations among individuals. Adjusted estimates indicated that sex and age can predictably influence the length of the pathway and the distance of the GPF from the ANS, supporting the use of patient-specific CBCT evaluations to identify landmarks for anesthesia through the canals or when planning posterior maxillary surgical procedures.