Ezgi Tüter Bayraktar

Dr. Ezgi Tüter Bayraktar

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 November 2022 in Polymers
Verified
Journal Article
Open access
PDF file
Pınar Yılmaz AtalıPınar Yılmaz Atalı
Pınar Yılmaz Atalı
BKBengü Doğu Kaya
Bengü Doğu Kaya
AÖAybike Manav Özen
Aybike Manav Özen
BTBilge Tarçın
Bilge Tarçın
AŞAYŞE ASLI ŞENOL
AYŞE ASLI ŞENOL
CTCafer Türkmen
Cafer Türkmen
Single-shade universal resin composites (SsURC) are preferred in clinical practice to reduce time for shade selection and obtain good esthetic results. In this study, the static mechanical properties of seven new SsURCs were investigated, their spectral analyzes were performed and scanning electron microscopy (SEM) evaluations were presented. Charisma Diamond One/DO, Admira Fusion x-tra/AFX, Omnichroma/OC, OptiShade/OS, Essentia Universal/EU, Zenchroma/ZC, Vittra APS Unique/VU were used in a three-point bending test to determine flexural strength (FS) and elastic modulus (EM); Vickers micro-hardness (VHN) and hardness-ratio (HR) were performed with a micro-hardness tester from top/bottom after 24-h/15-days of storage in distilled water at 37 °C (±1 °C). The degree of conversion (DC) was assessed by using Fourier transform infrared spectroscopy (FTIR). The structure of the resin matrix and filler content were assessed by SEM. Data were analyzed using IBM SPSS V23 and the R program and the significance level was taken as p < 0.05. The main effect of the tested SsURCs was found to be statistically significant on FS, EM, VHN, and DC values (p < 0.001). Bis-GMA free SsURCs (AFX, DO, VU) showed better DC and HR except for OC. All seven tested SsURCs conform to the requirements of ISO standards for dental resin composites for all tested categories.

26 May 2021 in European Journal of Dentistry
Verified
Journal Article
Open access
PDF file
EBEzgi Tüter Bayraktar
Ezgi Tüter Bayraktar
PAPinar Y. Atali
Pinar Y. Atali
BKBora Korkut
Bora Korkut
EKEzgi G. Kesimli
Ezgi G. Kesimli
BTBilge Tarcin
Bilge Tarcin
CTCafer Turkmen
Cafer Turkmen
Objectives This study was aimed to determine the effects of modeling resins on the surface microhardness of composites. Materials and Methods Six resin-based composites (Charisma Smart, Estellite Asteria, CeramX-One SphereTEC, Admira Fusion, Filtek Ultimate, and Clearfil Majesty Es-2) and three wetting agents (Modeling Liquid, Composite Primer, and Modeling Resin) were investigated. In all, 240 specimens were prepared, and wetting agents were applied prior to light curing in the experimental groups. After 24 hours, specimens were polished and Vickers microhardness (VHN) values were measured. Statistical Analysis Shapiro–Wilk and two-way analysis of variance (ANOVA) were used for analyses (p < 0.05). Results Both modeling resin and composites were determined to be effective factors (p < 0.001). The control group showed the highest VHN (70.37 ± 7.94), followed by Modeling Liquid (64.68 ± 12.07), Composite Primer (59.84 ± 6.33), and Modeling Resin (58 ± 3.52b; p < 0.001). Filtek Ultimate showed the highest VHN (76.62 ± 9.78c), whereas Charisma Smart (58.87 ± 7.95), and Clearfil Majesty (67.27 ± 2.58) showed the lowest (p < 0.001). Clearfil Majesty–Modeling Liquid (46.62 ± 5.33) and Charisma Smart–Composite Primer (50.81 ± 0.39) combinations showed the lowest VHN, whereas Filtek Ultimate–control (87.15 ± 2.12) and Filtek Ultimate–Modeling Liquid (84.24 ± 3.11) showed the highest (p < 0.001). Conclusion All tested modeling resins decreased VHN value, and the amount of reduction varied among composites and wetting agents. It might be safer not to use wetting agents unless they are necessary. Article published online: 26 May 2021 © 2021. European Journal of Dentistry. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/). Thieme Medical and Scientific Publishers Pvt. Ltd. A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

25 January 2024 in Dental Materials Journal
Verified
Journal Article
Open access
PDF file
EBEzgi Tüter Bayraktar
Ezgi Tüter Bayraktar
CTCafer Türkmen
Cafer Türkmen
PAPınar Yilmaz Atali
Pınar Yilmaz Atali
BTBilge Tarçin
Bilge Tarçin
BKBora Korkut
Bora Korkut
BYBilal Yaşa
Bilal Yaşa
The aim of this study was to demonstrate the vertical and volumetric wear characteristics of CAD/CAM materials. The microhardness and color stability were evaluated. A polymer infiltrated ceramic network CAD/CAM block, resin nanoceramic CAD/CAM blocks, a resin composite, and enamel tissue were investigated. Samples were loaded in a chewing simulator. Other samples were aged and immersed in coffee. Color change was evaluated using the digital image analysis and a spectrophotometer. The data were analyzed using Kolmogorov-Smirnov, Kruskal Wallis, Mann Whitney U, Friedman, Spearman’s rho tests (p<0.05). The lowest level of wear was obtained in enamel tissue group 0.20 (Q1:0.14; Q3:0.27μm). Resin composite group 2.48 (Q1:2.12; Q3:2.92) showed lower level of discoloration. No agreement was obtained between the digital image analysis and spectrophotometer data (Spearman’s rho −0.314, p=0.014). Similar wear rate to the natural enamel tissue was obtained for Vita Enamic. Digital image analysis was considered a promising technique for monitoring the color change.

21 November 2024 in Clinical Oral Investigations
Verified
Journal Article
Closed access
PDF file
EBEzgi Tüter Bayraktar
Ezgi Tüter Bayraktar
EÖEzgi Kızıl Öztürk
Ezgi Kızıl Öztürk
CSCevdet Can Saygılı
Cevdet Can Saygılı
CTCafer Türkmen
Cafer Türkmen
BKBora Korkut
Bora Korkut

23 May 2025 in Journal of Esthetic and Restorative Dentistry
Verified
Journal Article
Open access
BKBora Korkut
Bora Korkut
IOIbrahim Ograk
Ibrahim Ograk
NMNaci Murat
Naci Murat
PNPanagiotis Ntovas
Panagiotis Ntovas
EBEzgi Tüter Bayraktar
Ezgi Tüter Bayraktar
RSRoberto Sorrentino
Roberto Sorrentino
Objectives: To evaluate the effect of maxillary midline deviation and crown width disproportion on the perception of smile attractiveness through full‐face images among dentists and laypeople. Methods and Materials: A full portrait image of a smiling 25‐year‐old female, exhibiting good dental alignment, midline position, and tooth size symmetry, was selected as a model for the present study. The original image was digitally modified using photo editing software (Photoshop CC, Version 25.12.0; Adobe) to simulate three different case scenarios of varying levels: Midline deviation (1–4 mm), single crown width disproportion, separately for central incisor, lateral incisor, and canine (1 and 2 mm), and crown width disproportions distributed to anterior teeth (1–4 mm). In total, 15 modified images were displayed randomly to 180 observers (90 laypeople and 90 dentists) including the original image that served as a control. Each observer scored the level of smile esthetics for each image using a visual analog scale ranging from point 0 (unattractive) to 100 (attractive). Bonferroni Test and Partial Eta Squared were utilized for the statistical data analyses ( α < 0.05). Results: Attractiveness scores were significantly lower for the modified smiles with the single crown width disproportion than distributed crown width disproportion and midline deviation ( p < 0.001 for each), of which two presented statistically similar attractiveness ( p = 0.278). The highest attractiveness scores were obtained for the control image (90.35 ± 5.56 A ), midline deviation of 1 mm (88.89 ± 5.93 AB ), 2 mm (86.80 ± 6.70 ABC ), and distributed disproportion of crown width of 1 mm (87.75 ± 6.70 AB ). A single central incisor disproportion of 2 mm (45.51 ± 11.94 I ) was perceived significantly less attractive, followed by a midline deviation of 4 mm (57.51 ± 12.58 H ) and a distributed disproportion of crown width of 4 mm (59.11 ± 9.72 H ). Modified images were perceived as significantly more attractive by laypeople and male observers compared to dentists and female observers ( p < 0.001 for each). Older observers between 35 and 50 years old scored significantly higher than younger observers ( p = 0.001). Conclusions: Dentofacial midline discrepancy had less effect on smile attractiveness compared to crown width disproportions. Midline deviations up to 2 mm were not noticeable for both laypeople and dentists. The deviations of 3 mm were noticeable but still more attractive than the deviations of 4 mm, which were considered the least attractive. A single crown width disproportion was less perceived when moving from the central incisor toward the canine. Distributing the crown width disproportions among anterior teeth can be beneficial for smile attractiveness compared to non‐distributed cases. Clinical Significance: Generating symmetrical crown width proportions of the anterior teeth seems more important for smile esthetics than dentofacial midline harmony. Distribution of crown width disproportions among the anterior teeth can enhance smile esthetics.

18 March 2026 in Journal of Endodontics
Verified
Journal Article
Closed access
AKAyse Karadayi
Ayse Karadayi
HUHatice Beyza Uzun
Hatice Beyza Uzun
GBGülsüm Kutlu Basmaci
Gülsüm Kutlu Basmaci
EBEzgi Tüter Bayraktar
Ezgi Tüter Bayraktar
HOHesna Sazak Ovecoglu
Hesna Sazak Ovecoglu