Nikolay Dovgilov

Nikolay Dovgilov


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 September 2023 in Izmeritel`naya Tekhnika
Verified
Journal Article
Closed access
PDF file
NDNikolay Dovgilov
Nikolay Dovgilov
SMS. P. Morozova
S. P. Morozova
SAS. V. Alekseev
S. V. Alekseev
ADA. Yu. Dunaev
A. Yu. Dunaev
VGV. R. Gavrilov
V. R. Gavrilov
VVV. N. Vasiliev
V. N. Vasiliev
The structure of the systems for the radiometric calibration of the remote sensing optoelectronic equipment in the infrared spectral range is presented. The analysis of existing facilities for the radiometric calibration of the remote sensing optoelectronic equipment in conditions of vacuum and low-background radiation was carried out. These facilities are based on using of the blackbody models as radiation sources, including reference sources based on the phase transition of pure metals, for example gallium or indium. The wide-aperture blackbody model LABB-380 with an aperture diameter of 380 mm in the temperature range from 223.15 K up to 423.15 K has been developed for a high-vacuum low-background stand, which is currently being developed at the Sciences Research Institute of Optoelectronic Instrumentation for the radiometric calibration of the remote sensing optoelectronic equipment. The results of calculating the normal effective emissivity of the surface of the LABB-380 in the temperature range from 223.15 K to 423.15 K in the spectral range from 3 to 20 μm are presented. The metrological characteristics of LABB-380 obtained during the transmission of a temperature unit from the zero discharge State Standard using a comparator based on the precision pyrometer HETRONIXS are investigated and presented. The instability of the LABB-380 radiation was 0.005 K according to the calibration results in the temperature range from 300.15 K to 390.15 K, and the extended temperature uncertainty was 0.66 K at the temperature of 300.15 K and 0.88 K at a temperature of 390.15 K.

3 April 2025 in Izmeritel`naya Tekhnika
Verified
Journal Article
Closed access
PDF file
ADA. Yu. Dunaev Yu. Dunaev
A. Yu. Dunaev Yu. Dunaev
SMS. P. Morozova
S. P. Morozova
VGV. R. Gavrilov
V. R. Gavrilov
VBV. S. Bormashov
V. S. Bormashov
NDNikolay Dovgilov
Nikolay Dovgilov
The issues of metrological ensures for measurements of the spectral characteristics of radiation receivers in a wide spectral range, in particular from the ultraviolet to the terahertz range are consider. Until now, measurements of the spectral sensitivity of receivers in the wavelength range greater than 14 μm have not been metrologically supported, which their use for measuring the power of terahertz radiation when solving problems in the field of medicine, safety and climatology excluded. A reference receiver of terahertz radiation has been developed, manufactured and studied in order to solve the problem of reproducing and transmitting the unit of spectral sensitivity of radiation receivers in the wavelength range of 14–300 μm with traceability to an absolute cryogenic radiometer. The operating principle and design of the developed receiver are described, its metrological characteristics are studied and presented. The components of the uncertainty of the reproduction of the unit of spectral sensitivity of the reference receiver of terahertz radiation are calculated. The uncertainty budget for the reproduction of the unit of spectral sensitivity in the wavelength range of 14–300 μm is presented. An installation based on a monochromatic source of terahertz radiation and a standard receiver of terahertz radiation have been developed. The installation is designed to transfer a unit of spectral sensitivity to receivers of terahertz radiation. The research results are of great importance for many branches of science and technology, since spectral sensitivity measurements are widely used in astrophysics, lighting engineering, geophysics, biophysics, biology, medicine, agriculture, chemistry, metallurgy, etc.

14 November 2023 in Izmeritel`naya Tekhnika
Verified
Journal Article
Closed access
PDF file
NDNikolay Dovgilov
Nikolay Dovgilov
SMS. P. Morozova
S. P. Morozova
SAS. V. Alekseev
S. V. Alekseev
ADA. Yu. Dunaev
A. Yu. Dunaev
VGV. R. Gavrilov
V. R. Gavrilov
VVV. N. Vasiliev
V. N. Vasiliev
The issues of radiometric calibration of optical-electronic equipment for remote sensing of the Earth in a wide range of spectral radiance have been studied. An alternative method for transmitting a spectral radiance unit from a reference source at the phase transition temperature of pure metals to optical-electronic equipment for remote sensing of the Earth in the infrared wavelength range above 2.5 μm is presented. The method is based on the stepwise transfer of a spectral radiance unit from a reference source through a precision model of a black body with a high level of emissivity and a wide temperature range identical to the temperature range of a wide-aperture black body model with a range of spectral radiance required for calibrating optical-electronic equipment for remote sensing of the Earth. A precision black body model PMBB-60m with an output aperture with a diameter of 30 mm was developed, studied and calibrated in the temperature range of 200–450 K. The calculated value of the effective emissivity of PMBB-60m with coating of the cavity by Aeroglaze Z306 paint is 0.9997. The composition and design of PMBB-60m are described. PMBB-60m can operate both in vacuum conditions and in conditions of inert gas or atmospheric pressure. The metrological characteristics of PMBB-60m , obtained by transferring a temperature unit from the State Standard of the zero digit of a temperature unit in the range from 0 to 3000 °C using a comparator, based on a precision pyrometer TRT II (Heitronics Infrarot Messtechnik GmbH, Germany) are presented. The correction to the PMBB-60m temperature readings in the temperature range of 223.15–450.15 K did not exceed 39 mK according to the results of calibration in the temperature range of 223.15–450.15 K. The results of calculating the expanded uncertainty in the temperature range of 223.15–450.15 K did not exceed 1 K. The values of instability of temperature maintenance PMBB-60m, measured in steps of 10 s for 15 minutes, did not exceed 15 mK in the considered temperature range. The results of calculation of the spectral effective emissivity of PMBB-60m, carried out using the STEEP3 program, are presented.


1 May 2025 in Measurement Techniques
Verified
Journal Article
Closed access
PDF file
ADA. Yu. Dunaev
A. Yu. Dunaev
SMS. P. Morozova
S. P. Morozova
VGV. R. Gavrilov
V. R. Gavrilov
VBV. S. Bormashov
V. S. Bormashov
NDNikolay Dovgilov
Nikolay Dovgilov

14 November 2023 in Izmeritel`naya Tekhnika
Verified
Journal Article
Closed access
NDNikolay Dovgilov
Nikolay Dovgilov
SMS. P. Morozova
S. P. Morozova
SAS. V. Alekseev
S. V. Alekseev
ADA. Yu. Dunaev
A. Yu. Dunaev
VGV. R. Gavrilov
V. R. Gavrilov
VVV. N. Vasiliev
V. N. Vasiliev
The issues of radiometric calibration of optical-electronic equipment for remote sensing of the Earth in a wide range of spectral radiance have been studied. An alternative method for transmitting a spectral radiance unit from a reference source at the phase transition temperature of pure metals to optical-electronic equipment for remote sensing of the Earth in the infrared wavelength range above 2.5 μm is presented. The method is based on the stepwise transfer of a spectral radiance unit from a reference source through a precision model of a black body with a high level of emissivity and a wide temperature range identical to the temperature range of a wide-aperture black body model with a range of spectral radiance required for calibrating optical-electronic equipment for remote sensing of the Earth. A precision black body model PMBB-60m with an output aperture with a diameter of 30 mm was developed, studied and calibrated in the temperature range of 200–450 K. The calculated value of the effective emissivity of PMBB-60m with coating of the cavity by Aeroglaze Z306 paint is 0.9997. The composition and design of PMBB-60m are described. PMBB-60m can operate both in vacuum conditions and in conditions of inert gas or atmospheric pressure. The metrological characteristics of PMBB-60m , obtained by transferring a temperature unit from the State Standard of the zero digit of a temperature unit in the range from 0 to 3000 °C using a comparator, based on a precision pyrometer TRT II (Heitronics Infrarot Messtechnik GmbH, Germany) are presented. The correction to the PMBB-60m temperature readings in the temperature range of 223.15–450.15 K did not exceed 39 mK according to the results of calibration in the temperature range of 223.15–450.15 K. The results of calculating the expanded uncertainty in the temperature range of 223.15–450.15 K did not exceed 1 K. The values of instability of temperature maintenance PMBB-60m, measured in steps of 10 s for 15 minutes, did not exceed 15 mK in the considered temperature range. The results of calculation of the spectral effective emissivity of PMBB-60m, carried out using the STEEP3 program, are presented.