1 January 1993 in Metrologia
11 January 2021 in Metrologia
Main text: The EURAMET.PR-S5 intercomparison of the short circuit current of reference solar cells at standard test conditions was carried out as star type comparison. In total 6 participants with seven facilities took part, 1 from Europe (PTB/Germany with two facilities: the established DSR facility as pilot lab and the new Laser-DSR facility as participant) and 5 outside Europe (NIM/China, VNIIOFI/Russia, KRISS/South Korea, A-STAR/Singapore, ITRI/Chinese Taipei). Therefore, this comparison can be considered as a worldwide one as all NMIs world-wide that had built up facilities for the primary ISTC-calibration of reference solar cells when the measurements started, participated. For the calculation of the reference value of the supplementary comparison no participant had to be excluded and the used weighted mean with cut-off has been supported by all participants. The unilateral Degrees of Equivalence (DoE) calculated for each participant are fully 100 % consistent with their standard uncertainties. The largest En-value is 0.61 and therefore significant smaller than 1. The chi-square test is fully satisfied with 2.09 < χ 2 (5) = 11.07. Thus, the DSR method is highly suitable for the calibration of reference solar cells according to the short circuit current at standard test conditions. To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/ . The final report has been peer-reviewed and approved for publication by the CCPR, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
3 April 2025 in Izmeritel`naya Tekhnika
The issues of metrological ensures for measurements of the spectral characteristics of radiation receivers in a wide spectral range, in particular from the ultraviolet to the terahertz range are consider. Until now, measurements of the spectral sensitivity of receivers in the wavelength range greater than 14 μm have not been metrologically supported, which their use for measuring the power of terahertz radiation when solving problems in the field of medicine, safety and climatology excluded. A reference receiver of terahertz radiation has been developed, manufactured and studied in order to solve the problem of reproducing and transmitting the unit of spectral sensitivity of radiation receivers in the wavelength range of 14–300 μm with traceability to an absolute cryogenic radiometer. The operating principle and design of the developed receiver are described, its metrological characteristics are studied and presented. The components of the uncertainty of the reproduction of the unit of spectral sensitivity of the reference receiver of terahertz radiation are calculated. The uncertainty budget for the reproduction of the unit of spectral sensitivity in the wavelength range of 14–300 μm is presented. An installation based on a monochromatic source of terahertz radiation and a standard receiver of terahertz radiation have been developed. The installation is designed to transfer a unit of spectral sensitivity to receivers of terahertz radiation. The research results are of great importance for many branches of science and technology, since spectral sensitivity measurements are widely used in astrophysics, lighting engineering, geophysics, biophysics, biology, medicine, agriculture, chemistry, metallurgy, etc.
23 January 2021 in Measurement Techniques
1 May 2025 in Measurement Techniques