Jonas Widmer

Dr. Jonas Widmer


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2020 in The Spine Journal
Verified
Journal Article
Open access
JWJonas Widmer
Jonas Widmer
FCFrédéric Cornaz
Frédéric Cornaz
GSGita Scheibler
Gita Scheibler
JSJosé Miguel Spirig
José Miguel Spirig
JSJess G. Snedeker
Jess G. Snedeker
MFMazda Farshad
Mazda Farshad
The contribution of anatomical structures to the stability of the spine is of great relevance for diagnostic, prognostic and therapeutic evaluation of spinal pathologies. Although a plethora of literature is available, the contribution of anatomical structures is still not well understood. We aimed to quantify the biomechanical relevance of each of the passive spinal structure trough deliberate biomechanical test series using a stepwise reduction approach on cadavers. Biomechanical cadaveric study. 50 lumbar spinal segments originating from 22 human lumbar cadavers were biomechanically tested in a displacement-controlled stepwise reduction study: The intertransverse ligaments (ITL), the supraspinous and interspinous ligaments (ISL&SSL), the facet joint capsules (FJC), the facet joints (FJ), the ligamentum flavum (LF), the posterior longitudinal ligament (PLL) and the anterior longitudinal ligament (ALL) were subsequently reduced. In the intact state and after each transection step, the segments were physiologically loaded in flexion, extension, axial rotation (AR), lateral bending (LB) and with anterior (AS), posterior (PS) and lateral shear (LS). 32 specimens with only minor degeneration, representing a reasonably healthy subpopulation, were selected for the here presented evaluation. Quantitative values for load and spinal level dependent contribution patterns for the anatomical structures were derived. Small variability between of the contribution patterns are observed. The intervertebral disc (IVD) is exposed to about 67% of the applied load in LB and during shear loading, but less by load in flexion, extension and AR (less than 35%). The FJ&FJC are the main stabilizers in AR with 49%, but provide only 10% of the stability in extension. Beside the IVD, the LF and the PLL contribute mainly in flexion (22% and 16% respectively), while the ALL plays a major role during extension (40%) and also contributes during LB (15%). The contribution of the ITL and the ISL&SSL are very small in all loading directions (<2% and <6% respectively). The IVD takes the main load in LB and absorbs shear loading, while the FJ&FJC stabilize AR. The ALL resists extension while LF and PLL stabilize flexion. With the small variability of contribution patterns, suggesting distinct adaptation of the structures to one another, the biomechanical characteristics of one structure have to be put in context of the whole spinal segment.

10 December 2022 in Annals of Biomedical Engineering
Verified
Journal Article
Open access
PDF file
SLSara Lindenmann
Sara Lindenmann
CTChristos Tsagkaris
Christos Tsagkaris
MFMazda Farshad
Mazda Farshad
JWJonas Widmer
Jonas Widmer
Knowledge of spinal kinematics is essential for the diagnosis and management of spinal diseases. Distinguishing between physiological and pathological motion patterns can help diagnose these diseases, plan surgical interventions and improve relevant tools and software. During the last decades, numerous studies based on diverse methodologies attempted to elucidate spinal mobility in different planes of motion. The authors aimed to summarize and compare the evidence about cervical spine kinematics under healthy and degenerative conditions. This includes an illustrated description of the spectrum of physiological cervical spine kinematics, followed by a comparable presentation of kinematics of the degenerative cervical spine. Data was obtained through a systematic MEDLINE search including studies on angular/translational segmental motion contribution, range of motion, coupling and center of rotation. As far as the degenerative conditions are concerned, kinematic data regarding disc degeneration and spondylolisthesis were available. Although the majority of the studies identified repeating motion patterns for most motion planes, discrepancies associated with limited sample sizes and different imaging techniques and/or spine configurations, were noted. Among healthy/asymptomatic individuals, flexion extension (FE) and lateral bending (LB) are mainly facilitated by the subaxial cervical spine. C4–C5 and C5–C6 were the major FE contributors in the reported studies, exceeding the motion contribution of sub-adjacent segments. Axial rotation (AR) greatly depends on C1–C2. FE range of motion (ROM) is distributed between the atlantoaxial and subaxial segments, while AR ROM stems mainly from the former and LB ROM from the latter. In coupled motion rotation is quantitatively predominant over translation. Motion migrates caudally from C1–C2 and the center of rotation (COR) translocates anteriorly and superiorly for each successive subaxial segment. In degenerative settings, concurrent or subsequent lesions render the association between diseases and mobility alterations challenging. The affected segments seem to maintain translational and angular motion in early and moderate degeneration. However, the progression of degeneration restrains mobility, which seems to be maintained or compensated by adjacent non-affected segments. While the kinematics of the healthy cervical spine have been addressed by multiple studies, the entire nosological and kinematic spectrum of cervical spine degeneration is partially addressed. Large—scale in vivo studies can complement the existing evidence, cover the gaps and pave the way to technological and clinical breakthroughs.

1 April 2019 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
JWJonas Widmer
Jonas Widmer
PFPaolo Fornaciari
Paolo Fornaciari
MSMarco Senteler
Marco Senteler
TRTabitha Roth
Tabitha Roth
JSJess G. Snedeker
Jess G. Snedeker
MFMazda Farshad
Mazda Farshad

7 January 2020 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
JWJonas Widmer
Jonas Widmer
MFMarie-Rosa Fasser
Marie-Rosa Fasser
ECEleonora Croci
Eleonora Croci
JSJosé Spirig
José Spirig
JSJess G. Snedeker
Jess G. Snedeker
MFMazda Farshad
Mazda Farshad
Pedicle screws are used for the treatment of a wide variety of spinal pathologies. A good screw holding power in bone is required for treatment success, but has so far not been predictable computationally. The goal of this study was to develop an automated tool able to predict patient-specific screw fixation strength through finite element simulation. We compared the simulation results with results from biomechanical pull-out tests performed on animal lumbar specimens. Experimental and simulation pull-out strengths were highly correlated (ρSpearman=0.821, p<0.0001) and the mean error was 20.25%. The fixation strength was also associated to great extent with pull-out stiffness and strain energy, as well as the screw size and mean vertebral density.

1 January 2020 in Journal of Biomechanics
Verified
Journal Article
Closed access
FCFrédéric Cornaz
Frédéric Cornaz
MFMarie-Rosa Fasser
Marie-Rosa Fasser
JSJosé Miguel Spirig
José Miguel Spirig
JSJess G. Snedeker
Jess G. Snedeker
MFMazda Farshad
Mazda Farshad
JWJonas Widmer
Jonas Widmer

29 November 2018 in at - Automatisierungstechnik
Verified
Journal Article
Closed access
PDF file
LBLina M. Beltran Bernal
Lina M. Beltran Bernal
ISIris T. Schmidt
Iris T. Schmidt
NVNikola Vulin
Nikola Vulin
JWJonas Widmer
Jonas Widmer
JSJess G. Snedeker
Jess G. Snedeker
GRGeorg Rauter
Georg Rauter
Conventional bone surgery leads to unwanted damage to the surrounding tissues and a slow healing process for the patients. Additionally, physicians are not able to perform free cutting shapes due to the limitations of available systems. These issues can be overcome by robot-assisted contactless laser surgery since it provides less mechanical stress, allows precise functional cuts, and leads to faster healing. The remaining drawback of laser surgery is the low ablation rate that is not yet competitive with conventional mechanical piezo-osteotomes. Therefore, we aim at maximizing the efficiency in hard tissue laser ablation by optimizing the lateral movement speed for different irrigation conditions. The results of this study show a non-linear relationship between cutting rates, speeds, and depths that should be critically considered for integration in robotic laser surgery.