Frédéric Cornaz

Frédéric Cornaz

Auto-generated profile, based on publicly available information

Frédéric Cornaz

Spine Biomechanics, Department of Orthopedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2021 in The Spine Journal
Verified
Journal Article
Open access
FCFrédéric Cornaz
Frédéric Cornaz
JWJonas Widmer
Jonas Widmer
NFNadja A. Farshad-Amacker
Nadja A. Farshad-Amacker
JSJosé Miguel Spirig
José Miguel Spirig
JSJess G. Snedeker
Jess G. Snedeker
MFMazda Farshad
Mazda Farshad
The ligamentum flavum (LF), the inter- and supraspinous ligament (ISL&SSL) and the intertransverse ligament (ITL) are relevant spinal structures for segmental stability. The biomechanical effect of degeneration and aging on their biomechanical properties remains largely unknown. The aim of this study was to assess the material properties of the ITL, ISL&SSL and LF and to correlate parameters of biomechanical function with LF-thickness, intervertebral disc (IVD) degeneration and age. Biomechanical cadaveric study. MRI- and CT-scans of 50 human lumbar segments (Th12-L5) were used to assess the ISL (acc. to Keorochana), the grade of IVD degeneration (acc. to Pfirrmann) and to quantify LF-thickness. The ITL, ISL&SSL and LF were resected in the neutral position of the spinal segment with a specifically developed method to conserve initial strain. Ramp to failure testing was performed (0.5 mm/s) to record initial tension, slack length, stiffness and ultimate strength. The relationship between the biomechanical characteristics and age and radiological parameters were analyzed. There are no study-specific conflicts of interest and no external funding was received for this study. With aging, a significant reduction in initial tension (r=-0.5, p<0.01) and ultimate strength (r=-0.41, p<0.01) of the LF was observed, while the effect on LF-stiffness and the characteristics of the other ligaments was non-significant. IVD-degeneration was correlated with a significant reduction in stiffness (r=-0.47, p=0.001; r=-0.36, p=0.01) and ultimate strength (r=-0.3, p=0.04; r=-0.36, p=0.01) of the LF and ISL&SSL respectively and a significant reduction in initial tension (r=-0.4, p0.05). LF-thickness did not correlate with the biomechanical properties of the LF (p>0.05). Aging is primarily related to biomechanical changes to the LF. IVD-degeneration is related to a relevant reduction in stiffness and ultimate strength of the LF and ISL&SSL, with a similar trend for the ITL. The ISL-specific Keorochana grading system provides only minimal biomechanical information and LF-thickness does not provide biomechanical information. Patient age and the degenerative state of the IVD can be used to evaluate the biomechanical characteristics of the dorsal spinal ligaments, which can be helpful in selecting the optimal surgical procedure (e.g. in decompression surgery) for a specific situation.

3 October 2020 in European Spine Journal
Verified
Journal Article
Open access
PDF file
FCFrédéric Cornaz
Frédéric Cornaz
JWJonas Widmer
Jonas Widmer
JSJess Gerrit Snedeker
Jess Gerrit Snedeker
JSJosé Miguel Spirig
José Miguel Spirig
MFMazda Farshad
Mazda Farshad
Purpose: Dorsal screw-rod instrumentations are used for a variety of spinal disorders. Cross-links (CL) can be added to such constructs, however, no clear recommendations exist. This study aims to provide an overview of the available evidence on the effectiveness of CL, potentially allowing to formulate recommendations on their use. Methods: A systematic literature review was performed on PubMed and 37 original articles were included and grouped into mechanical, biomechanical, finite element and clinical studies. The change in range of motion (ROM) was analyzed in mechanical and biomechanical studies, ROM, stiffness and stress distribution were evaluated in finite element studies and clinical outcome parameters were analyzed in clinical studies. Results: A relative consistent reduction in ROM in axial rotation with CL-augmentation was reported, while minor and less consistent effects were observed in flexion–extension and lateral bending. The use of CLs was clinical beneficial in C1/2 fusion, while the limited clinical studies on other anatomic regions show no significant benefit for CL-augmentation. Conclusion: While CL provides some additional axial rotation stability in most situations, lateral bending and flexion–extension are less affected. Based on clinical data, CL-augmentation can only be recommended for C1/2 instrumentations, while for other cases, further clinical studies are needed to allow for evidence-based recommendations.

24 April 2023 in European Spine Journal
Verified
Journal Article
Open access
PDF file
Marco D. BurkhardMarco D. Burkhard
Marco D. Burkhard
ACAnna-Katharina Calek
Anna-Katharina Calek
MFMarie-Rosa Fasser
Marie-Rosa Fasser
FCFrédéric Cornaz
Frédéric Cornaz
JWJonas Widmer
Jonas Widmer
MFMazda Farshad
Mazda Farshad
Purpose: The aim of this study was to elucidate segmental range of motion (ROM) before and after common decompression and fusion procedures on the lumbar spine. Methods: ROM of fourteen fresh-frozen human cadaver lumbar segments (L1/2: 4, L3/4: 5, L5/S1: 5) was evaluated in six loading directions: flexion/extension (FE), lateral bending (LB), lateral shear (LS), anterior shear (AS), axial rotation (AR), and axial compression/distraction (AC). ROM was tested with and without posterior instrumentation under the following conditions: 1) native 2) after unilateral laminotomy, 3) after midline decompression, and 4) after nucleotomy. Results: Median native ROM was FE 6.8°, LB 5.6°, and AR 1.7°, AS 1.8 mm, LS 1.4 mm, AC 0.3 mm. Unilateral laminotomy significantly increased ROM by 6% (FE), 3% (LB), 12% (AR), 11% (AS), and 8% (LS). Midline decompression significantly increased these numbers to 15%, 5%, 21%, 20%, and 19%, respectively. Nucleotomy further increased ROM in all directions, most substantially in AC of 153%. Pedicle screw fixation led to ROM decreases of 82% in FE, 72% in LB, 42% in AR, 31% in AS, and 17% in LS. In instrumented segments, decompression only irrelevantly affected ROM. Conclusions: The amount of posterior decompression significantly impacts ROM of the lumbar spine. The here performed biomechanical study allows creation of a simplified rule of thumb: Increases in segmental ROM of approximately 10%, 20%, and 50% can be expected after unilateral laminotomy, midline decompression, and nucleotomy, respectively. Instrumentation decreases ROM by approximately 80% in bending moments and accompanied decompression procedures only minorly destabilize the instrumentation construct.

23 December 2022 in JOR SPINE
Verified
Journal Article
Open access
IHIrina Heggli
Irina Heggli
CLChristoph J. Laux
Christoph J. Laux
TMTamara Mengis
Tamara Mengis
AKAgnieszka Karol
Agnieszka Karol
FCFrédéric Cornaz
Frédéric Cornaz
SDStefan Dudli
Stefan Dudli
Background: Vertebral endplate signal intensity changes visualized by magnetic resonance imaging termed Modic changes (MC) are highly prevalent in low back pain patients. Interconvertibility between the three MC subtypes (MC1, MC2, MC3) suggests different pathological stages. Histologically, granulation tissue, fibrosis, and bone marrow edema are signs of inflammation in MC1 and MC2. However, different inflammatory infiltrates and amount of fatty marrow suggest distinct inflammatory processes in MC2.Aims: The aims of this study were to investigate (i) the degree of bony (BEP) and cartilage endplate (CEP) degeneration in MC2, (ii) to identify inflammatory MC2 pathomechanisms, and (iii) to show that these marrow changes correlate with severity of endplate degeneration.Methods: Pairs of axial biopsies (n = 58) spanning the entire vertebral body including both CEPs were collected from human cadaveric vertebrae with MC2. From one biopsy, the bone marrow directly adjacent to the CEP was analyzed with mass spectrometry. Differentially expressed proteins (DEPs) between MC2 and control were identified and bioinformatic enrichment analysis was performed. The other biopsy was processed for paraffin histology and BEP/CEP degenerations were scored. Endplate scores were correlated with DEPs.Results: Endplates from MC2 were significantly more degenerated. Proteomic analysis revealed an activated complement system, increased expression of extracellular matrix proteins, angiogenic, and neurogenic factors in MC2 marrow. Endplate scores correlated with upregulated complement and neurogenic proteins.Discussion: The inflammatory pathomechanisms in MC2 comprises activation of the complement system. Concurrent inflammation, fibrosis, angiogenesis, and neurogenesis indicate that MC2 is a chronic inflammation. Correlation of endplate damage with complement and neurogenic proteins suggest that complement system activation and neoinnervation may be linked to endplate damage. The endplate‐near marrow is the pathomechanistic site, because MC2 occur at locations with more endplate degeneration.Conclusion: MC2 are fibroinflammatory changes with complement system involvement which occur adjacent to damaged endplates.

1 January 2020 in Journal of Biomechanics
Verified
Journal Article
Closed access
FCFrédéric Cornaz
Frédéric Cornaz
MFMarie-Rosa Fasser
Marie-Rosa Fasser
JSJosé Miguel Spirig
José Miguel Spirig
JSJess G. Snedeker
Jess G. Snedeker
MFMazda Farshad
Mazda Farshad
JWJonas Widmer
Jonas Widmer

3 November 2023 in The Spine Journal
Verified
Journal Article
Open access
ACAnna-Katharina Calek
Anna-Katharina Calek
FCFrédéric Cornaz
Frédéric Cornaz
MSMauro Suter
Mauro Suter
MFMarie-Rosa Fasser
Marie-Rosa Fasser
SBSina Baumgartner
Sina Baumgartner
JWJonas Widmer
Jonas Widmer
Posterior and transforaminal lumbar interbody fusion (PLIF, TLIF) are well-established procedures for spinal fusion. However, little is known about load sharing between cage, dorsal construct, and biological tissue within the instrumented lumbar spine. The aim of this study was to quantify the forces acting on cages under axial compression force with and without posterior instrumentation. Biomechanical cadaveric study. Ten lumbar spinal segments were tested under uniaxial compression using load cell instrumented intervertebral cages. The force was increased in 100N increments to 1000N or a force greater than 500N on one load cell. Each specimen was tested after unilateral PLIF (uPLIF), bilateral PLIF (bPLIF) and TLIF each with/without posterior instrumentation. Dorsal instrumentation was performed with 55N of compression per side. Cage insertion resulted in median cage preloads of 16N, 29N and 35N for uPLIF, bPLIF, and TLIF. The addition of compressed dorsal instrumentation increased the median preload to 224N, 328N, and 317N, respectively. With posterior instrumentation, the percentage of the external load acting on the intervertebral cage was less than 25% at 100N (uPLIF: 14.2%; bPLIF: 16%; TLIF: 11%), less than 45% at 500N (uPLIF: 31.8%; bPLIF: 41.1%; TLIF: 37.9%) and less than 50% at 1000N (uPLIF: 40.3%; bPLIF: 49.7%; TLIF: 43.4%). Without posterior instrumentation, the percentage of external load on the cages was significantly higher with values above 50% at 100N (uPLIF: 55.6%; bPLIF: 75.5%; TLIF: 66.8%), 500N (uPLIF: 71.7%; bPLIF: 79.2%; TLIF: 65.4%), and 1000N external load (uPLIF: 73%; bPLIF: 80.5%; TLIF: 66.1%). For absolute loads, preloads and external loads must be added together. Without posterior instrumentation, the intervertebral cages absorb more than 50% of the axial load and the load distribution is largely independent of the loading amplitude. With posterior instrumentation, the external load acting on the cages is significantly lower and the load distribution becomes load amplitude dependent, with a higher proportion of the load transferred by the cages at high loads. The bPLIF cages tend to absorb more force than the other two cage configurations. Cage instrumentation allows some of the compression force to be transmitted through the cage to the screws below, better distributing and reducing the overall force on the pedicle screws at the end of the construct and on the rods.