Javier Moreno-Andrés

Dr. Javier Moreno-Andrés

Department of Environmental Technologies, Faculty of Marine and Environmental Sciences, INMAR-Marine Research Institute, CEIMAR- International Campus of Excellence of the Sea, University of Cadiz, 11003 Cádiz, Spain
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2019 in Science of The Total Environment
Verified
Journal Article
Open access
OHOle-Kristian Hess-Erga
Ole-Kristian Hess-Erga
Javier Moreno-AndrésJavier Moreno-Andrés
Javier Moreno-Andrés
ØEØivind Enger
Øivind Enger
OVOlav Vadstein
Olav Vadstein
Increasing concerns have accelerated the development of international regulations and methods for ballast water management to limit the introduction of non-indigenous species. The transport of microorganisms with ballast water has received scientific attention in recent years. However, few studies have focused on the importance of organisms smaller than 10 μm in diameter. In this work, we review the effects of ballast water transport, disinfection, and the release of microorganisms on ecosystem processes with a special focus on heterotrophic bacteria. It is important to evaluate both direct and indirect effects of ballast water treatment systems, such as the generation of easily degradable substrates and the subsequent regrowth of heterotrophic microorganisms in ballast tanks. Disinfection of water can alter the composition of bacterial communities through selective recolonization in the ballast water or the recipient water, and thereby affects bacterial driven functions that are important for the marine food web. Dissolved organic matter quality and quantity and the ecosystem status of the treated water can also be affected by the disinfection method used. These side effects of disinfection should be further investigated in a broader context and in different scales (laboratory studies, large-scale facilities, and on the ships).

1 September 2018 in Water Research
Verified
Journal Article
Closed access
Javier Moreno-AndrésJavier Moreno-Andrés
Javier Moreno-Andrés
NANoëmi Ambauen
Noëmi Ambauen
OVOlav Vadstein
Olav Vadstein
CHCynthia Hallé
Cynthia Hallé
AAAsunción Acevedo-Merino
Asunción Acevedo-Merino
TMThomas Meyn
Thomas Meyn

1 January 2016 in Chemical Engineering Journal
Verified
Journal Article
Closed access
Javier Moreno-AndrésJavier Moreno-Andrés
Javier Moreno-Andrés
LRLeonardo Romero-Martínez
Leonardo Romero-Martínez
AAAsunción Acevedo-Merino
Asunción Acevedo-Merino
ENEnrique Nebot
Enrique Nebot

31 January 2023 in Water Research
Verified
Journal Article
Open access
Javier Moreno-AndrésJavier Moreno-Andrés
Javier Moreno-Andrés
MTMiguel Tierno-Galán
Miguel Tierno-Galán
LRLeonardo Romero-Martinez
Leonardo Romero-Martinez
AAAsunción Acevedo-Merino
Asunción Acevedo-Merino
ENEnrique Nebot
Enrique Nebot
Ultraviolet (UV) radiation is a well-implemented process for water disinfection. The development of emergent UV sources, such as light-emitting diodes (LEDs), has afforded new possibilities for advanced oxidation processes. The emission wavelength is considered to be an important factor for photo-chemical processes in terms of both biological damage and energetic efficiency, as the inactivation mechanisms and mode-of-action may differ according to the wavelength that is applied. In addition, these processes merit exploration for inactivating emerging pathogens, such as marine vibrios, that are important bacteria to control in maritime activities. The main goal of this study was to compare the disinfection efficacy of several UV-LED driven processes with different modes of action. First, the effect of UV-LEDs was assessed at different UV ranges (UV-A, UV-B, or UV-C). Second, the possible enhancement of a combination with hydrogen peroxide (H2O2) or peroxymonosulfate salt (HSO5-) was investigated under two different application strategies, i.e. simultaneous or sequential. The results obtained indicate a high sensitivity of Vibrio alginolyticus to UV radiation, especially under UV-B (kobs = 0.24 cm2/mJ) and UV-C (kobs = 1.47 cm2/mJ) irradiation. The highest inactivation rate constants were obtained for UV/HSO5- (kobs (cm2/mJ)=0.0007 (UV-A); 0.39 (UV-B); 1.79 (UV-C)) with respect to UV/H2O2 (kobs (cm2/mJ)=0.0006 (UV-A); 0.26 (UV-B); and 1.54 (UV-C)) processes, however, regrowth was avoided only with UV/H2O2. Additionally, the disinfection enhancement caused by a chemical addition was more evident in the order UV-A > UV-B > UV-C. By applying H2O2 (10 mg/L) or HSO5- (2.5 mg/L) in a sequential mode before the UV, negligible effects were obtained in comparison with the simultaneous application. Finally, promising electrical energy per order (EEO) values were obtained as follows: UV/HSO5- (EEO (kWh/m3)=1.68 (UV-A); 0.20 (UV-B); 0.04 (UV-C)) and UV/H2O2 (EEO (kWh/m3)=2.15 (UV-A); 0.32 (UV-B); 0.04 (UV-C)), demonstrating the potential of UV-LEDs for disinfection in particular activities such as the aquaculture industry or maritime transport.

1 October 2019 in Water Research
Verified
Journal Article
Closed access
Javier Moreno-AndrésJavier Moreno-Andrés
Javier Moreno-Andrés
GFGonzalo Farinango
Gonzalo Farinango
LRLeonardo Romero-Martinez
Leonardo Romero-Martinez
AAAsunción Acevedo-Merino
Asunción Acevedo-Merino
ENEnrique Nebot
Enrique Nebot

1 December 2018 in Applied Catalysis B: Environment and Energy
Verified
Journal Article
Closed access
ILIrina Levchuk
Irina Levchuk
MKMarcela Kralova
Marcela Kralova
JRJuan José Rueda-Márquez
Juan José Rueda-Márquez
Javier Moreno-AndrésJavier Moreno-Andrés
Javier Moreno-Andrés
SGSergio Gutiérrez-Alfaro
Sergio Gutiérrez-Alfaro
MMManuel A. Manzano
Manuel A. Manzano