Recommendations regarding disinfection by-products (DBPs) in pool waters consider the content of trihalomethanes (THMs) and combined chlorine (CC) as indicators of DBPs based on which the health risk for swimmers and staff of pool facility can be determined. However, the content of DBPs in swimming pools depends on many factors. In this paper, the influence of selected factors (physicochemical parameters of water and technological parameters) on the content of THMs and CC in pool water was determined. During the 6-month period, 9 pools of various functions were analyzed. The water in pools was subjected to the same method of treatment. The content of THMs and CC was compared against the content of organic matter, free chlorine and nitrates, pH, temperature, redox potential and turbidity, technological, and operational parameters. The THM content did not exceed the limit value of 0.1 mg/L. The content of CC varied significantly, from 0.05 to 1.13 mg Cl2/L. It was found that a very large water volume per person, in comparison to a very small one, contributed to the low content of CC and THMs. The high load expressed as m3 of water per person or m2 of water per person and the specific function of hot tubs (HT1 and HT2) led to the average concentration of CC in these pools exceeding 0.3 mg Cl2/L. The THM concentrations in hot tubs (especially in HT1) were also among the largest (0.038–0.058 mg/L). In terms of the analyzed microbiological indicators, the quality of the tested pool water samples was not in doubt. It was found that the purpose of the pool, its volume, and number of swimmers should be the key parameters that determine the choice of methods of water treatment. The research on the pool water quality in the actual working conditions of swimming pool facilities is necessary due to the need to preserve the health safety of swimmers and staff.

1 July 2017 in Journal of Ecological Engineering
Verified
Journal Article
Open access
EŁEdyta Łaskawiec
Edyta Łaskawiec
MDMariusz Dudziak
Mariusz Dudziak
MMMarta Madej
Marta Madej
JWJoanna Wyczarska-Kokot
Joanna Wyczarska-Kokot
The paper has determined the suitability of membrane processes (UF ultrafiltration, UF, and nanofiltration, NF) for the purification of waste streams, so-called backwash water, obtained from washing filtration beds in a swimming pool water system. The backwash water samples were taken from the...

25 March 2019 in Membranes
Verified
Journal Article
Open access
PDF file
MDMariusz Dudziak
Mariusz Dudziak
JWJoanna Wyczarska-Kokot
Joanna Wyczarska-Kokot
EŁEdyta Łaskawiec
Edyta Łaskawiec
ASAgnieszka Stolarczyk
Agnieszka Stolarczyk
Swimming pool water was treated using an ultrafiltration process using ceramic and polymer membranes for comparison. It was determined that the efficiency of the process depended on the type of membrane used. The polymer membrane decreased the absorbance and concentration of combined chlorine in the pool water to a greater extent than the ceramic membrane. In the case of a ceramic membrane, the concentration of combined chlorine in the permeate exceeded the limit values. During the ultrafiltration process, the permeate flux decreased, causing the blockage of membrane pores. The extent of this phenomenon was similar for both tested membranes. In the case of the ceramic membrane, flushing it with water could significantly restore its initial performance. For both tested membranes, a high regeneration efficiency was observed during chemical treatment with an alkaline solution. SEM photos of the polymer membrane showed low resistance of this polymer to the chlorine present in the swimming pool water.

1 January 2018 in Journal of Ecological Engineering
Verified
Journal Article
Open access
MDMariusz Dudziak
Mariusz Dudziak
Edyta Kudlek-TymoszukEdyta Kudlek-Tymoszuk
Edyta Kudlek-Tymoszuk
EŁEdyta Łaskawiec
Edyta Łaskawiec
EFEwa Felis
Ewa Felis
KKKatarzyna Kowalska
Katarzyna Kowalska
LGLeon Garbaczewski
Leon Garbaczewski
New priorities for the environment have resulted in a reassessment of modern technology for treatment of urban wastewater. Urban wastewater treatment mainly involves the elimination or reduction of anthropogenic organic micropollutants in the aquatic environment. In this paper, the effectiveness of bisphenol A elimination from wastewater, after biological treatment, through a complex ultrafiltration/reverse osmosis purification process was evaluated. The effectiveness of the wastewater treatment process in the tested system was also evaluated with a number of other physical and chemical analyses for pH, turbidity, colour, absorbance, TOC, phenol index, conductivity and the concentration of selected heavy metals. Within this study, the change in the hydraulic performance of the membranes was also investigated. The effectiveness of the reduction of bisphenol A concentrations during the process of ultrafiltration was small, due to the significant difference between the size of the pores of the membrane and the size of eliminated micropollutants. In the process of reverse osmosis, the wastewater treatment system reported that the concentration of bisphenol A was reduced by 68%. In the tested treatment system, the ultrafiltration/reverse osmosis completely removed colour, lead and chromium. Other contaminants were eliminated by more than 31%. In both membrane processes, there was evidence that the membrane pores were blocked, but this occurred to a greater extent during the process of reverse osmosis.

17 January 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
EŁEdyta Łaskawiec
Edyta Łaskawiec
Swimming pools are examples of water-intensive facilities, where solutions for reducing economic and environmental costs are searched with increased frequency. One of the solutions supporting savings is the recovery of water from wastewater, including backwash water obtained while rinsing the filter bed. The study objective was the qualitative and quantitative assessment of post-coagulation sludges, the main pollutant found in the washings. During the analyses, assessment of the sedimentation capabilities of the sludges was performed (gravitationally), particle size distribution was assessed (particle size distribution analyser) and assessment of phytotoxicity with the use of plant indicators in short-term tests was performed (Lemna minor, Lepidium sativum, Sinapis alba, Raphanus sativus). The samples were collected from two independent circulations, which differed in terms of capacity and type of coagulant used. The tested post-coagulation sludges were characterized by high content of total suspended solids: in samples from Circuit 1 from 251 to 128 mg/L, in Circuit 2 from 489 to 228 mg/L. However, the sedimentation processes enabled significant separation of sludges. The hydrolyzed coagulant contributed to the improvement of sedimentation capabilities of the sludges. Despite the fact that in many samples low sludge concentrations favored stimulation of plant growth, the post-coagulation sludges can constitute a hazard to plant growth, particularly in the long-term perspective.

30 December 2015 in Acta Universitatis Lodziensis. Folia Biologica et Oecologica
Verified
Journal Article
Open access
PDF file
EŁEdyta Łaskawiec
Edyta Łaskawiec
This review discusses the importance of ecotones with high plant diversity which are highly effective in retaining pollutants and waste. Biogeochemical barriers play a vital role in eliminating biogenic pollutants, pesticides and heavy metals. Belts of rush plants and meadow vegetation considerably expand the accumulation capacity of water bodies and watercourses. The mechanisms responsible for the protective role of biogeochemical barriers involve various processes such as sorption, sedimentation, denitrification and assimilation, which require the coexistence of plants and microorganisms in aquatic ecosystems. Buffer barriers were presented as one of the ecohydrology tools in agricultural landscapes. Bariery biogeochemiczne stanowią obszary o potencjalnie dużej zdolności do ograniczania przedostawania się metali ciężkich, pestycydów oraz związków biogenicznych do środowiska wodnego. Zastosowanie rozwiązań ekohydrologicznych pozwala na regulację nadwyżki pierwiastków biogenicznych oraz przyczynia się do wzorstu bioróżnorodności, dzięki wytworzeniu siedlisk dla licznych gatunków roślin i zwierząt. W niniejszym opracowaniu włączono bariery biogeochemiczne w ogół układów buforowych. Rozwiązania tego typu mogą być traktowane, jako filtry marginalne umiejscowione bezpośrednio w strefie przybrzeżnej ekosystemu wodnego, co w przypadku wysokiego wstępnego obciążenia spływu powierzchniowego może okazać się nie wystarczające dla osiągnięcia dobrych efektów biofiltracji. Aby w sposób skuteczny przeciwdziałać degradacji ekosystemów wodnych na obszarach rolnicznych, konieczne jest zwiększenie powierzchni strefy oddzielającej je od wód oraz wykorzystanie zróżnicowanej roślinności. W obrębie stref buforowych wyróżnia się asymilację związków nieorganicznych, w tym azotu i fosforu przez rośliny, co umożliwia ich transformację w biomasę, a także procesy biogeochemiczne realizowane dzięki aktywności drobnoustrojów występujących w postaci biofilmów. Ponadto proces sorpcji i transportu rozpuszczalnych oraz nierozpuszczalnych związków fosforu realizowany jest w glebie, gdzie odpływ krąży w jej wierzchniej warstwie. Skuteczne działanie stref buforowych powinno obejmować preferencje siedlisk, określone rodzaje roślinności i ich tolerancję dla różnych warunków hydrologicznych. Przytoczone badania zwracają uwagę na konieczność zachowania zróżnicowanych gatunków w obrębie stref buforowych. Obecność na obszarze jednego siedliska zarówno drzew, krzewów i traw zapewnia ponad 90% efektywność w usuwaniu związków biogenicznych. Zapewnienie odpowiednich warunków dla współistnienia wielu organizmów w obrębie jednego ekotonu pozwala na skuteczne działanie procesów samooczyszczania i redukuje ryzyko degradacji ekosystemu.