Integral-imaging technology has demonstrated its capability for computing depth images from the microimages recorded after a single shot. This capability has been shown in macroscopic imaging and also in microscopy. Despite the possibility of refocusing different planes from one snap-shot is crucial for the study of some biological processes, the main drawback in integral imaging is the substantial reduction of the spatial resolution. In this contribution we report a technique, which permits to increase the two-dimensional spatial resolution of the computed depth images in integral microscopy by a factor of √2. This is made by a double-shot approach, carried out by means of a rotating glass plate, which shifts the microimages in the sensor plane. We experimentally validate the resolution enhancement as well as we show the benefit of applying the technique to biological specimens.
Integral Imaging provides spatial and angular information of three-dimensional (3D) objects, which can be used both for 3D display and for computational post-processing purposes. In order to recover the depth information from an integral image, several algorithms have been developed. In this paper, we propose a new free depth synthesis and reconstruction method based on the two-dimensional (2D) deconvolution between the integral image and a simplified version of the periodic impulse response function (IRF) of the system. The period of the IRF depends directly on the axial position within the object space. Then, we can retrieve the depth information by performing the deconvolution with computed impulse responses with different periods. In addition, alternative reconstructions can be obtained by deconvolving with non-conventional synthetic impulse responses. Our experiments show the feasibility of the proposed method as well as its potential applications.
Integral microscopy is a novel technique that allows the simultaneous capture of multiple perspective images of microscopic samples. This feature is achieved at the cost of a significant reduction of the spatial resolution. In fact, it is assumed that in the best cases the resolution is reduced by a factor that is not smaller than ten, what poses a hard drawback to the utility of the technique. However, to the best of our knowledge, this resolution limitation has never been researched rigorously. For this reason, the aim of this paper is to explore the real limitations in resolution of integral microscopy and to obtain optically, without the need of any image-processing algorithm, perspective images with the best resolution ever achieved in integral microscopy. This result opens a wide range of new possibilities of using integral microscopy in any imaging application were micron resolution is required.
Integral microscopy is a 3D imaging technique that permits the recording of spatial and angular information of microscopic samples. From this information it is possible to calculate a collection of orthographic views with full parallax and to refocus computationally, at will, through the 3D specimen. An important drawback of integral microscopy, especially when dealing with thick samples, is the limited depth of field (DOF) of the perspective views. This imposes a significant limitation on the depth range of computationally refocused images. To overcome this problem, we propose here a new method that is based on the insertion, at the pupil plane of the microscope objective, of an electrically controlled liquid lens (LL) whose optical power can be changed by simply tuning the voltage. This new apparatus has the advantage of controlling the axial position of the objective focal plane while keeping constant the essential parameters of the integral microscope, that is, the magnification, the numerical aperture and the amount of parallax. Thus, given a 3D sample, the new microscope can provide a stack of integral images with complementary depth ranges. The fusion of the set of refocused images permits to enlarge the reconstruction range, obtaining images in focus over the whole region.
Non-scanning, single-shot, 3D integral microscopy with optical sectioning is presented. The method is based on the combination of Fourier-mode integral microscopy with a 3D deconvolution technique. Specifically, the refocused volume provided by a regular back-projection algorithm is 3D deconvolved with a synthetic 3D impulse response function that takes into account the number and positions of the elemental images. The use of this hybrid technique provides a stack of true-color depth-refocused images with significant gain of optical sectioning. The stack can be used, among other applications, to inspect inside the thick microscope specimen, to calculate collections of perspective views with fine angular resolution and extended full parallax, and also to display 3D images in an integral monitor. The method here presented is validated with both simulation and experimental data.
An analysis and comparison of the lateral and the depth resolution in the reconstruction of 3D scenes from images obtained either with a classical two view stereoscopic camera or with an Integral Imaging (InI) pickup setup is presented. Since the two above systems belong to the general class of multiview imaging systems, the best analytical tool for the calculation of lateral and depth resolution is the ray-space formalism, and the classical tools of Fourier information processing. We demonstrate that InI is the optimum system to sampling the spatio-angular information contained in a 3D scene.