Grid-connected converters are exposed to the loss of synchronisation with the grid during severe voltage sags particularly when operating under weak grid condition which introduces voltage and frequency volatility. This paper presents employing machine learning methods besides modifying the converter control scheme to enhance the transient stability of power synchronization control (PSC). For early detection of synchronization instability of PSC to provide adequate time for taking correcting control actions, an encoder stacked classifier is proposed which is trained to be robust against data corruption and added noise. Then, by integrating the proposed instability detection scheme to the synchronization loop of PSC, a phase freezing mode is introduced to avoid losing synchronism during grid faults. It is disclosed that the frozen synchronization loop, which is activated by the proposed instability detection scheme, can ensure synchronization stability of PSC. Time-domain simulations are conducted to confirm the presented findings.
This paper presents a synchronous resonant control strategy based on the inherent characteristics of permanent magnet synchronous generators (PMSG) for the control of power converters to provide stable operating conditions for the power grid under high penetration of renewable energy resources (RERs). The proposed control technique is based on the small signal linearization of a dynamic model with grid specifications, load-current-based voltages, and power converter currents. A combination of the linearized dynamic model with the PMSG swing equation and resonant controller leads to a control technique with synchronous features and appropriate inertia for the control of converter-based power generators. As the main contribution of this work, an extra functionality is proposed in the control loop of the proposed model to solve the inherent inconveniences of conventional synchronous generators. Also, a comprehensive collaboration between interfaced converter specifications and PMSG features is achieved as another contribution of the proposed control technique, and this can guarantee accurate performance under various conditions. A current perturbation curve is introduced to assess the variations of the grid frequency and voltage magnitude under operation of the interfaced converters controlled by the proposed control technique. Moreover, by taking into account the load-based voltages, the effects of the current perturbation components are investigated. The proposed model is simulated in MATLAB/Simulink environment to verify the high performance of the proposed control technique over the other existing control methods.
This paper proposes a developed control technique for integration of renewable energy sources into the weak grids. The developed controller alleviates the negative impact of weak grid operating condition on the stability of interface converters by mean of impedance reshaping technique. Furthermore, the proposed controller provides virtual inertia to support the power grid stability. Satisfactory and stable operation of the interface converter as well as providing virtual inertia under weak grid condition with high penetration level of RESs, are the main contributions of this paper. Comparative simulation results are presented to demonstrate and verify the effectiveness of the proposed control technique.
Since the electrolytic capacitors are mainly responsible for breakdowns in power electronics converters, they usually determine the overall lifetime. Their failure is due to the deterioration of their dielectric, the production of gases, and, eventually, their explosion. The deterioration process leads to a decrease in its capacitance value and simultaneously, an increase in the capacitor equivalent series resistance (ESR). In this paper, a novel noninvasive technique for failure prediction of the electrolytic capacitors in grid-connected photovoltaic inverters is presented, which can easily be applied online and even in the real time. The technique is based on the DC-link voltage measurement, current calculation, and extracting the current integral and the voltage change during switching intervals. Then, the capacitance can be calculated using the recursive least squares method. Although the estimation results are influenced by the temperature at which the measurement is performed, and the results are dependent on the operating conditions, but the proposed method is modified to obviate the above distorting factors effectively. The proposed technique is simple to apply, accurate and does not need to any extra hardware. Also it can be adapted for any other inverter based applications. The performance of the proposed method is verified by the simulation and experimental results.