Assisting underwater movements improves divers' efficiency and reduces the risk of decompression sickness from physical activity. Although exoskeletons have been developed for numerous land-based scenarios, their application in underwater diving remains unexplored. This paper proposes a soft underwater lower-limb exosuit designed to assist three aquatic movements: flutter kick, breaststroke kick, and underwater walk. We presented the mechanical design of the exosuit that is capable of assisting bidirectional leg movements in full kicking/gait cycle, while ensuring natural leg mobility without impeding normal leg function. A cascade force integral controller is also designed to resolve issues related to uncontrollable states and stiffness variations within the system. To verify the assistive performance of the system, experiments were conducted with nine participants to assess how the proposed exosuit aids in reducing metabolic cost across various motion patterns and frequencies. The findings indicate that the underwater exosuit effectively reduces the air consumption rate by $29.77\pm 7.68$% during flutter kick, $25.70\pm 5.99$% during breaststroke kick, and $18.35\pm 4.53$% during underwater walk.
26 February 2025 in IEEE Transactions on Automation Science and Engineering
Exosuits play an essential role in facilitating rehabilitation training for patients with functional impairments. However, the safety of human-exosuit interactions and their adaptability to varied environments are crucial challenges that hinder their transition from laboratory prototypes to practical real-world applications. This study presents an innovative active exosuit designed to correct foot drop, characterized by its safe interactive performance and terrain daptability. Regarding safe human-exosuit interaction, meticulous design of the dimensions of hinge module ensures that, upon contact between the hinges, the driving rope reaches its maximum contraction length, thereby mechanically safeguarding against excessive dorsiflexion of the ankle joint by preventing further stretch. In terms of adaptability to various terrains, a visual system capable of terrain recognition has been integrated, enabling a seamless transition between control modes based on the detected terrain, achieving a recognition accuracy of 99.1% through the Transformer in Transformer (TNT) algorithm. To quantify the effect of the exosuit in correcting drop-foot, five healthy participants with artificially induced impairment were recruited to participate in the experiment. The experimental results revealed that the peak of the plantarflexion angle was decreased by 21.3%, 26.0%, and 46.5%, respectively, with the assistance of an exosuit when walking at the terrains of level ground (LG), upramps (UR), and upstairs (US). The root mean square (RMS) of the electromyography (EMG) signals of the tibialis anterior (TA) muscle was reduced by 26.9%, 32.5%, and 20.2%, respectively. These initial results demonstrate that the exosuit can effectively assist dorsiflexion at different terrains.
Work-related shoulder disorders during overhead assembly represent a persistent occupational challenge. We evaluated a quasi-direct-drive (QDD) active upper-limb exoskeleton during simulated overhead work, providing simultaneous metabolic, electromyographic, and kinematic assessment of QDD actuation under static and dynamic conditions. Seven healthy males completed within-subject comparisons of without-exoskeleton (WO) and with-exoskeleton (WE) conditions during dynamic screwing (5 min) and static holding (2.5 min, 3 kg). During static holding, the exoskeleton achieved substantial shoulder offloading (Upper Trapezius: −68.2%, 6/6 participants, p = 0.031, d = 3.61; Anterior Deltoid: −43.6%) and improved postural stability (32–41% variability reduction). However, metabolic cost increased during both static (+57.2%) and dynamic (+30.6%) tasks, while movement smoothness degraded. These findings extend prior task-dependent exoskeleton observations to QDD actuation, revealing that intrinsic backdrivability does not eliminate whole-body energy penalties from device mass. The exoskeleton exhibits task-dependent effectiveness: potentially suitable for prolonged static overhead holding but not currently recommended for dynamic assembly without mass reduction and control refinement.
23 October 2025 in IEEE Transactions on Medical Robotics and Bionics
Lower limb exoskeleton robots (LLERs) are being increasingly used by individuals with lower limb disorders for autonomous walking and rehabilitation training, eliminating the need for help from people. A key issue regarding the application of LLERs is the accurate walking gait prediction, which remains a significant research challenge. The purpose of this article is to present an innovative gait prediction framework, a meta-learning based neural network (MLformer), that can accurately predict the gait for the wearer of an LLER in complex motion situations, such as cross-speed and cross-subject scenarios. This framework integrates a residual network (ResNet), vision transformers (ViTs), and a meta-learning structure to address the challenge of gait prediction across multiple scenarios on small sample datasets. The ResNet and ViT are effective at extracting local and global features, respectively. Moreover, meta-learning networks are well-suited for tasks involving few-sample learning. Finally, the results of comprehensive experiments, including a cross-speed prediction experiment, a cross-subject prediction experiment, and a physical experiment, demonstrate the effectiveness, strong generalizability and reliability of the proposed MLformer.
25 December 2025 in IEEE/ASME Transactions on Mechatronics
This article presents the mechanism design, balanced walking control strategy, and experimental implementation of a self-balancing bipedal exoskeleton (SBBE) AutoLEE-G3. Based on the anatomical structures of the lower limbs of human, we developed a bioinspired 12 actuated-joint prototype, AutoLEE-G3, which can assist all lower limb joints of the wearer, with motions including hip abduction/adduction, hip flexion/extension, hip internal/external rotation, knee flexion/extension, ankle inversion/eversion, and ankle dorsi flexion/plantar flexion during walking. Subsequently, a viscoelastic-compliance-based balance controller (VCBC) was proposed to reduce the detrimental influence of impact forces on the SBBE's balance performance. Furthermore, the VCBC is based on centroid dynamics, and its control performance is independent of the distributed mass of the exoskeleton and the wearer, which is highly advantageous for the balance control of SBBEs, as the distributed mass of the exoskeleton, particularly that of the wearer, is difficult to measure accurately. Finally, the validity of the self-balancing and locomotion capabilities of AutoLEE-G3 is successfully confirmed through straight-line and turning walking experiments involving both a dummy subject and two human subjects.