. The standard formula used to estimate the radiation extinction coefficient, kb (m–1), of solid porous natural fuel beds is examined and tested against laboratory experiments with isotropic beds of pine needles in the range of packing ratio, β, of 0.01–0.02. To measure kb in the tests, a setup using a parallel beam of white light radiation was constructed. The error of the standard formula is observed to be smaller than 10%. Similar tests were performed for a non-isotropic bed of pine needles with β ≈ 0.02, in which the maximum angle of inclination of the needles was limited to 30°, for two directions of incidence of radiation: horizontal and vertical. For each one of these two cases, original estimation formulae for kb are proposed alternative to the standard one. In these cases it is concluded that, while the standard formula may be in error by up to 20%, the new formulae have errors around 5% or smaller.
A unitary view of the most common formulations that have been proposed and used to model the movement and shape of forest fire fronts is given in this paper. The whole set of formulations is designated as the local quasi-equilibrium approach or model after the main physical hypothesis in which it is based. The physical and analytical aspects of the local quasi-equilibrium model are developed. Three main formulations based, respectively, on the Fermat principle, Huygens principle and the normal fire rate of spread, are given to the model and mutually compared. Some key considerations and proposals regarding the experimental test of the model are also presented. Finally, the main open issues are outlined.
Laboratory fire tests were performed in still air, for variable inclinations (10°, 15°) and fuel bed dimensions (1.28 × 2.50–3.0 × 4.6 m2), with homogeneous fuel beds of pine needles and pine wood excelsior. The fire ignition was made at a point, along a closed line with no fuel inside and along a straight edge of the fuel bed. The tests were recorded with an infrared camera and various techniques were developed to implement direct and indirect empirical methods of construction of the ‘orientation function’ of the fire in the given fuel bed and ambient conditions, showing how the rate of spread of a steady straight fire front depends on its orientation on the terrain. The direct method uses a set of straight fire fronts with various orientations whereas the indirect method uses essentially a point ignited fire front. Contrary to what is assumed in BehavePlus model, the orientation function is observed to depend significantly on the properties of the fuel bed. In all tests with closed fire fronts, the full steadiness required by the indirect method was not achieved (namely, at the head of the front), although, for slope angle of 10°, the corresponding errors induced on the orientation function were small.
This study presents an experimental and numerical investigation into the performance and control optimization of an Organic Rankine Cycle (ORC)-based micro-combined heat and power (micro-CHP) system. A steady-state, off-design, charge-sensitive model is developed to design a control strategy for an ORC micro-CHP combi-boiler, aiming to efficiently meet real-time domestic hot water demands (up to 40 °C and 35 kW) while generating up to 2 kW of electricity. The system utilizes a natural gas burner to evaporate the working fluid (R245fa), with combustion heat power, volumetric pump speed, and expander speed as control variables. Experimental and numerical evaluations generate steady-state control maps to identify optimal operating regions. A PID-based dynamic control strategy is then developed to stabilize operation during start-ups and user demand variations. The results confirm that the strategy delivers hot water within 1.5 min in simple boiler mode and 3 min in cogeneration mode while improving electricity generation stability and outperforming manual control. The findings demonstrate that integrating steady-state modeling with optimized control enhances the performance, responsiveness, and efficiency of ORC-based micro-CHP systems, making them a viable alternative for residential energy solutions.