Andrzej Liebert

Dr. Andrzej Liebert

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2021 in NeuroImage
Verified
Journal Article
Open access
MVMaximilian N. Voelker
Maximilian N. Voelker
OKOliver Kraff
Oliver Kraff
SGSteffen Goerke
Steffen Goerke
FLFrederik B. Laun
Frederik B. Laun
JHJannis Hanspach
Jannis Hanspach
HQHarald H. Quick
Harald H. Quick
This study evaluates inter-site and intra-site reproducibility at ten different 7 T sites for quantitative brain imaging. Two subjects - termed the "traveling heads" - were imaged at ten different 7 T sites with a harmonized quantitative brain MR imaging protocol. In conjunction with the system calibration, MP2RAGE, QSM, CEST and multi-parametric mapping/relaxometry were examined. Quantitative measurements with MP2RAGE showed very high reproducibility across sites and subjects, and errors were in concordance with previous results and other field strengths. QSM had high inter-site reproducibility for relevant subcortical volumes. CEST imaging revealed systematic differences between the sites, but reproducibility was comparable to results in the literature. Relaxometry had also very high agreement between sites, but due to the high sensitivity, differences caused by different applications of the B1 calibration of the two RF coil types used were observed. Our results show that quantitative brain imaging can be performed with high reproducibility at 7 T and with similar reliability as found at 3 T for multicenter studies of the supratentorial brain.

19 April 2019 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
ALAndrzej Liebert
Andrzej Liebert
MZMoritz Zaiss
Moritz Zaiss
RGRene Gumbrecht
Rene Gumbrecht
KTKatharina Tkotz
Katharina Tkotz
PLPeter Linz
Peter Linz
ANArmin M. Nagel
Armin M. Nagel

17 March 2022 in NMR in Biomedicine
Verified
Journal Article
Open access
AMAngelika Mennecke
Angelika Mennecke
KKKatrin M. Khakzar
Katrin M. Khakzar
AGAlexander German
Alexander German
KHKai Herz
Kai Herz
MFMoritz S. Fabian
Moritz S. Fabian
MZMoritz Zaiss
Moritz Zaiss
The objective of the current study was to optimize the postprocessing pipeline of 7 T chemical exchange saturation transfer (CEST) imaging for reproducibility and to prove this optimization for the detection of age differences and differences between patients with Parkinson's disease versus normal subjects. The following 7 T CEST MRI experiments were analyzed: repeated measurements of a healthy subject, subjects of two age cohorts (14 older, seven younger subjects), and measurements of 12 patients with Parkinson's disease. A slab‐selective, ‐homogeneous parallel transmit protocol was used. The postprocessing, consisting of motion correction, smoothing, ‐correction, normalization, denoising, ‐correction and Lorentzian fitting, was optimized regarding the intrasubject and intersubject coefficient of variation (CoV) of the amplitudes of the amide pool and the aliphatic relayed nuclear Overhauser effect (rNOE) pool within the brain. Seven “tricks” for postprocessing accomplished an improvement of the mean voxel CoV of the amide pool and the aliphatic rNOE pool amplitudes of less than 5% and 3%, respectively. These postprocessing steps are: motion correction with interpolation of the motion of low‐signal offsets (1) using the amide pool frequency offset image as reference (2), normalization of the Z‐spectrum using the outermost saturated measurements (3), correction of the Z‐spectrum with moderate spline smoothing (4), denoising using principal component analysis preserving the 11 highest intensity components (5), correction using a linear fit (6) and Lorentzian fitting using the five‐pool fit model (7). With the optimized postprocessing pipeline, a significant age effect in the amide pool can be detected. Additionally, for the first time, an aliphatic rNOE contrast between subjects with Parkinson's disease and age‐matched healthy controls in the substantia nigra is detected. We propose an optimized postprocessing pipeline for CEST multipool evaluation. It is shown that by the use of these seven “tricks”, the reproducibility and, thus, the statistical power of a CEST measurement, can be greatly improved and subtle changes can be detected.

26 February 2021 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
ALAndrzej Liebert
Andrzej Liebert
KTKatharina Tkotz
Katharina Tkotz
JHJürgen Herrler
Jürgen Herrler
PLPeter Linz
Peter Linz
AMAngelika Mennecke
Angelika Mennecke
ANArmin M. Nagel
Armin M. Nagel
Purpose: To enable whole‐brain quantitative CEST MRI at ultra‐high magnetic field strengths (B0 ≥ 7T) within short acquisition times.Methods: Multiple interleaved mode saturation (MIMOSA) was combined with fast online‐customized (FOCUS) parallel transmission (pTx) excitation pulses and correction to achieve homogenous whole‐brain coverage. Examinations of 13 volunteers were performed on a 7T MRI system with 3 different types of pulse sequences: (1) saturation in circular polarized (CP) mode and CP mode readout, (2) MIMOSA and CP readout, and (3) MIMOSA and FOCUS readout. For comparison, the inverse magnetic transfer ratio metric for relayed nuclear Overhauser effect and amide proton transfer were calculated. To investigate the number of required acquisitions for a good correction, 4 volunteers were measured with 6 different B1 amplitudes. Finally, time point repeatability was investigated for 6 volunteers.Results: MIMOSA FOCUS sequence using correction, with both single and multiple points, reduced inhomogeneity of the CEST contrasts around the occipital lobe and cerebellum. Results indicate that the most stable inter‐subject coefficient of variation was achieved using the MIMOSA FOCUS sequence. Time point repeatability of MIMOSA FOCUS with single‐point correction showed a maximum coefficient of variation below 8% for 3 measurements in a single volunteer.Conclusion: A combination of MIMOSA FOCUS with a single‐point correction can be used to achieve quantitative CEST measurements at ultra‐high magnetic field strengths. Compared to previous correction methods, acquisition time can be reduced as additional scans required for correction can be omitted.

24 January 2022 in NMR in Biomedicine
Verified
Journal Article
Open access
PDF file
FGFelix Glang
Felix Glang
MFMoritz S. Fabian
Moritz S. Fabian
AGAlexander German
Alexander German
KKKatrin M. Khakzar
Katrin M. Khakzar
AMAngelika Mennecke
Angelika Mennecke
MZMoritz Zaiss
Moritz Zaiss
Isolated evaluation of multiparametric in vivo chemical exchange saturation transfer (CEST) MRI often requires complex computational processing for both correction of B0 and B1 inhomogeneity and contrast generation. For that, sufficiently densely sampled Z‐spectra need to be acquired. The list of acquired frequency offsets largely determines the total CEST acquisition time, while potentially representing redundant information. In this work, a linear projection‐based multiparametric CEST evaluation method is introduced that offers fast B0 and B1 inhomogeneity correction, contrast generation and feature selection for CEST data, enabling reduction of the overall measurement time. To that end, CEST data acquired at 7 T in six healthy subjects and in one brain tumor patient were conventionally evaluated by interpolation‐based inhomogeneity correction and Lorentzian curve fitting. Linear regression was used to obtain coefficient vectors that directly map uncorrected data to corrected Lorentzian target parameters. L1‐regularization was applied to find subsets of the originally acquired CEST measurements that still allow for such a linear projection mapping. The linear projection method allows fast and interpretable mapping from acquired raw data to contrast parameters of interest, generalizing from healthy subject training data to unseen healthy test data and to the tumor patient dataset. The L1‐regularization method shows that a fraction of the acquired CEST measurements is sufficient to preserve tissue contrasts, offering up to a 2.8‐fold reduction of scan time. Similar observations as for the 7‐T data can be made for data from a clinical 3‐T scanner. Being a fast and interpretable computation step, the proposed method is complementary to neural networks that have recently been employed for similar purposes. The scan time acceleration offered by the L1‐regularization (“CEST‐LASSO”) constitutes a step towards better applicability of multiparametric CEST protocols in a clinical context.

25 October 2024 in European Radiology
Verified
Journal Article
Open access
PDF file
ALAndrzej Liebert
Andrzej Liebert
HSHannes Schreiter
Hannes Schreiter
LKLorenz A. Kapsner
Lorenz A. Kapsner
JEJessica Eberle
Jessica Eberle
CEChris M. Ehring
Chris M. Ehring
SBSebastian Bickelhaupt
Sebastian Bickelhaupt
Objective: To investigate how different combinations of T1-weighted (T1w), T2-weighted (T2w), and diffusion-weighted imaging (DWI) impact the performance of virtual contrast-enhanced (vCE) breast MRI. Materials and methods: The IRB-approved, retrospective study included 1064 multiparametric breast MRI scans (age: 52 ± 12 years) obtained from 2017 to 2020 (single site, two 3-T MRI). Eleven independent neural networks were trained to derive vCE images from varying input combinations of T1w, T2w, and multi-b-value DWI sequences (b-value = 50–1500 s/mm2). Three readers evaluated the vCE images with regard to qualitative scores of diagnostic image quality, image sharpness, satisfaction with contrast/signal-to-noise ratio, and lesion/non-mass enhancement conspicuity. Quantitative metrics (SSIM, PSNR, NRMSE, and median symmetrical accuracy) were analyzed and statistically compared between the input combinations for the full breast volume and both enhancing and non-enhancing target findings. Results: The independent test set consisted of 187 cases. The quantitative metrics significantly improved in target findings when multi-b-value DWI sequences were included during vCE training (p < 0.05). Non-significant effects (p > 0.05) were observed for the quantitative metrics on the full breast volume when comparing input combinations including T1w. Using T1w and DWI acquisitions during vCE training is necessary to achieve high satisfaction with contrast/SNR and good conspicuity of the enhancing findings. The input combination of T1w, T2w, and DWI sequences with three b-values showed the best qualitative performance. Conclusion: vCE breast MRI performance is significantly influenced by input sequences. Quantitative metrics and visual quality of vCE images significantly benefit when multi b-value DWI is added to morphologic T1w-/T2w sequences as input for model training. Key Points: Question How do different MRI sequences impact the performance of virtual contrast-enhanced (vCE) breast MRI? Findings The input combination of T1-weighted, T2-weighted, and diffusion-weighted imaging sequences with three b-values showed the best qualitative performance. Clinical relevance While in the future neural networks providing virtual contrast-enhanced images might further improve accessibility to breast MRI, the significant influence of input data needs to be considered during translational research. Graphical