5 January 2021 in Magnetic Resonance in Medicine
Purpose: To mitigate spatial flip angle (FA) variations under strict specific absorption rate (SAR) constraints for ultra‐high field MRI using a combination of universal parallel transmit (pTx) pulses and fast subject‐specific optimization.Methods: Data sets consisting of B0, maps, and virtual observation point (VOP) data were acquired from 72 subjects (study groups of 48/12 healthy Europeans/Asians and 12 Europeans with pathological or incidental findings) using an 8Tx/32Rx head coil on a 7T whole‐body MR system. Combined optimization values (COV) were defined as combination of spiral‐nonselective (SPINS) trajectory parameters and an energy regularization weight. A set of COV was optimized universally by simulating the individual RF pulse optimizations of 12 training data sets (healthy Europeans). Subsequently, corresponding universal pulses (UPs) were calculated. Using COV and UPs, individually optimized pulses (IOPs) were calculated during the sequence preparation phase (maximum 15 s). Two different UPs and IOPs were evaluated by calculating their normalized root‐mean‐square error (NRMSE) of the FA and SAR in simulations of all data sets. Seven additional subjects were examined using an MPRAGE sequence that uses the designed pTx excitation pulses and a conventional adiabatic inversion.Results: All pTx pulses resulted in decreased mean NRMSE compared to a circularly polarized (CP) pulse (CP = ~28%, UPs = ~17%, and IOPs = ~12%). UPs and IOPs improved homogeneity for all subjects. Differences in NRMSE between study groups were much lower than differences between different pulse types.Conclusion: UPs can be used to generate fast online‐customized (FOCUS) pulses gaining lower NRMSE and/or lower SAR values.
26 February 2021 in Magnetic Resonance in Medicine
Purpose: To enable whole‐brain quantitative CEST MRI at ultra‐high magnetic field strengths (B0 ≥ 7T) within short acquisition times.Methods: Multiple interleaved mode saturation (MIMOSA) was combined with fast online‐customized (FOCUS) parallel transmission (pTx) excitation pulses and correction to achieve homogenous whole‐brain coverage. Examinations of 13 volunteers were performed on a 7T MRI system with 3 different types of pulse sequences: (1) saturation in circular polarized (CP) mode and CP mode readout, (2) MIMOSA and CP readout, and (3) MIMOSA and FOCUS readout. For comparison, the inverse magnetic transfer ratio metric for relayed nuclear Overhauser effect and amide proton transfer were calculated. To investigate the number of required acquisitions for a good correction, 4 volunteers were measured with 6 different B1 amplitudes. Finally, time point repeatability was investigated for 6 volunteers.Results: MIMOSA FOCUS sequence using correction, with both single and multiple points, reduced inhomogeneity of the CEST contrasts around the occipital lobe and cerebellum. Results indicate that the most stable inter‐subject coefficient of variation was achieved using the MIMOSA FOCUS sequence. Time point repeatability of MIMOSA FOCUS with single‐point correction showed a maximum coefficient of variation below 8% for 3 measurements in a single volunteer.Conclusion: A combination of MIMOSA FOCUS with a single‐point correction can be used to achieve quantitative CEST measurements at ultra‐high magnetic field strengths. Compared to previous correction methods, acquisition time can be reduced as additional scans required for correction can be omitted.
19 August 2021 in Magnetic Resonance in Medicine
Purpose: To improve pseudo‐continuous arterial spin labeling (pcASL) at 7T by exploiting a hybrid homogeneity‐ and efficiency‐optimized ‐shim with adapted gradient strength as well as background suppression.Methods: The following three experiments were performed at 7T, each employing five volunteers: (1) A hybrid (ie, homogeneity‐efficiency optimized) ‐shim was introduced and evaluated for variable‐rate selective excitation pcASL labeling. Therefore, ‐maps in the V3 segment and time‐of‐flight images were acquired to identify the feeding arteries. For validation, a gradient‐echo sequence was applied in circular polarized (CP) mode and with the hybrid ‐shim. Additionally, the gray matter (temporal) signal‐to‐noise ratio (tSNR) in pcASL perfusion images was evaluated. (2) Bloch simulations for the pcASL labeling were conducted and validated experimentally, with a focus on the slice‐selective gradients. (3) Background suppression was added to the ‐shimmed, gradient‐adapted 7T sequence and this was then compared to a matched sequence at 3T.Results: The ‐shim improved the signal within the labeling plane (23.6%) and the SNR/tSNR increased (+11%/+11%) compared to its value in CP mode; however, the increase was not significant. In accordance with the simulations, the adapted gradients increased the tSNR (35%) and SNR (45%) significantly. Background suppression further improved the perfusion images at 7T, and this protocol performed as well as a resolution‐matched protocol at 3T.Conclusion: The combination of the proposed hybrid ‐phase‐shim with the adapted slice‐selective gradients and background suppression shows great potential for improved pcASL labeling under suboptimal conditions at 7T.
21 January 2024 in Magnetic Resonance in Medicine
Purpose: To mitigate inhomogeneity at 7T for multi‐channel transmit arrays using unsupervised deep learning with convolutional neural networks (CNNs).Methods: Deep learning parallel transmit (pTx) pulse design has received attention, but such methods have relied on supervised training and did not use CNNs for multi‐channel maps. In this work, we introduce an alternative approach that facilitates the use of CNNs with multi‐channel maps while performing unsupervised training. The multi‐channel maps are concatenated along the spatial dimension to enable shift‐equivariant processing amenable to CNNs. Training is performed in an unsupervised manner using a physics‐driven loss function that minimizes the discrepancy of the Bloch simulation with the target magnetization, which eliminates the calculation of reference transmit RF weights. The training database comprises 3824 2D sagittal, multi‐channel maps of the healthy human brain from 143 subjects. data were acquired at 7T using an 8Tx/32Rx head coil. The proposed method is compared to the unregularized magnitude least‐squares (MLS) solution for the target magnetization in static pTx design.Results: The proposed method outperformed the unregularized MLS solution for RMS error and coefficient‐of‐variation and had comparable energy consumption. Additionally, the proposed method did not show local phase singularities leading to distinct holes in the resulting magnetization unlike the unregularized MLS solution.Conclusion: Proposed unsupervised deep learning with CNNs performs better than unregularized MLS in static pTx for speed and robustness.
24 May 2025 in Magnetic Resonance in Medicine
NMNatalia Pato Montemayor
+9
18 June 2024 in Magnetic Resonance in Medicine
Purpose: To investigate the impact of reduced k‐space sampling on mapping and the resulting impact on phase shimming and dynamic/universal parallel transmit (pTx) RF pulse design.Methods: Channel‐wise 3D maps were measured at 7 T in 35 and 23 healthy subjects for the heart and prostate region, respectively. With these maps, universal phase shims optimizing homogeneity and efficiency were designed for heart and prostate imaging. In addition, universal 4kT‐point pulses were designed for the heart. Subsequently, individual phase shims and individual 4kT‐pulses were designed based on maps with different acceleration factors and tested on the original maps. The performance of the pulses was compared by evaluating their coefficients of variation (CoV), efficiencies and specific energy doses (SED). Furthermore, validation measurements were carried out for one heart and one prostate subject.Results: For both organs, the universal phase shims showed significantly higher efficiencies and lower CoVs compared to the vendor provided default shim, but could still be improved with individual phase shims based on accelerated maps (acquisition time = 30 s). In the heart, the universal 4kT‐pulse achieved significantly lower CoVs than tailored phase shims. Tailored 4kT‐pulses based on accelerated maps resulted in even further reduced CoVs or a 2.5‐fold reduction in SED at the same CoVs as the universal 4kT‐pulse.Conclusion: Accelerated maps can be used for the design of tailored pTx pulses for prostate and cardiac imaging at 7 T, which further improve homogeneity, efficiency, or SED compared to universal pulses.