This study investigated whether verbal response time (RT) as a measure of listening effort in speech audiometry could be an indicator for identifying elderly individuals with mild cognitive impairm...
Background and Objectives: This study was performed to comprehensively examine the amplitudes of the binaural interaction components (BICs) elicited by chirps, clicks, and 500 Hz tone-burst stimuli in individuals with normal hearing. Electrophysiological evidence of BICs was obtained and assessed for correlations with interaural time difference (ITD) and interaural level difference (ILD).Subjects and Methods: Sixteen adults (4 males and 12 females) with normal hearing participated in this study. Auditory brainstem responses (ABRs) to chirp, click, and 500 Hz tone-burst stimuli were recorded, and BICs were derived based on wave V. The behavioral thresholds of ITDs and ILDs across multiple frequencies were obtained and analyzed.Results: BICs were found in most participants, regardless of stimulus type. The amplitudes of BICs elicited by chirps were the highest, followed by those elicited by clicks and 500 Hz tone-bursts. A significant correlation was found between the amplitudes of chirp-evoked BICs and the thresholds of 500 Hz ITDs and ILDs.Conclusions:This study found that chirp stimuli may be effective in eliciting BIC and predicting behavioral binaural interaction processing at low frequencies.
Purpose: Hearing loss not only causes restricted speech understanding, but also alters speech production resulting in poor intelligibility. This study investigated whether English fricatives /s/ and /ʃ/ spoken by people with severe-to-profound hearing loss acoustically differ from those spoken by normal hearing (NH) individuals. Methods: For hearing impaired (HI) group, we analyzed a part of deaf speech corpus collected at the Speech Perception Assessment Lab (SPAL) at the University of Memphis. From the big dataset, /aSa/ and /aSha/ recordings spoken by eight females were selected. For NH control group, Shannon’s consonant set (1999) spoken by eight females was used. A set of spectral moment analysis (Mean, Variance, Skewness, Kurtosis) along with spectral peak (SP) and wiener entropy (WE) were used as measures of spectral properties of /s/ and /ʃ/. Results: Variance and WE for HI were significantly higher than those for NH group (p<0.05). Mean and SP for /s/ were significantly greater in NH group, while Mean and SP for /ʃ/ were significantly greater in HI group (p<0.05). This trends suggest greater Mean and SP differences between /s/ and /ʃ/ for NH group than HI group. Conclusions: Based on our finding, Variance and WE are spectral measures that are different between NH and HI individuals’ spoken /s/ and /ʃ/. We assume that HI individuals likely pronounce /s/ and /ʃ/ without making clear distinction substituting by each other due probably to lack of auditory feedback or failure of motor control.
Purpose: Sound is localized by two ears. People with bilaterally severe-to-profound hearing loss may struggle to identify the direction of a sound if their hearing device delivers sound only one ear due to the loss of binaural advantage. The purpose of this study was to systematically investigate the sound localization performance of people with unilateral cochlear implant users. Methods: Ten unilateral cochlear implant users and 10 normal hearing adults participated in this study. Sound localization tests were conducted using five stimuli (speech, speech with noise, 500 Hz warble tone, 1 kHz warble tone, and 4 kHz warble tone) presented from eight loud-speakers. Correct responses and root- mean-square errors were obtained to investigate the localization performances and error patterns. Additional factors including the Korean-Speech Spatial and Qualities of Hearing Questionnaire were also analyzed. Results: Localization performance was significantly poor in the unilateral cochlear implant group showing polar patterns toward their hearing side. While the normal hearing group showed better localization for speech in quiet conditions compared to 500 Hz warble tone, the cochlear implant group did not show any statistical difference in performance across the stimuli due to their very poor performance. The Korean-Speech Spatial and Qualities of Hearing Questionnaire was associated with localization performance in limited conditions. Conclusion: The present study revealed that unilateral cochlear implant users correctly localize a sound at nearly chance levels. The Korean-Speech Spatial and Qualities of Hearing Questionnaire predict localization performance for unilateral cochlear implant users only for particular conditions.
Purpose: The binaural interaction component (BIC) is presumed to reflect binaural hearing abilities, including spatial hearing. This study aims to record BIC amplitudes and examine their relationship with behavioral auditory tests.Methods: Nine elderly adults with hearing loss (eight males and one female) participated in this study. The BIC was derived from the wave V amplitude of the auditory brainstem response (ABR) and the N1-P2 amplitude of the auditory late latency response (ALR). Behavioral auditory processing tests, including sentence recognition scores, localization scores, and masking level difference, were obtained and analyzed with respect to electrophysiological BICs.Results: BICs were more reliably identified in ALR compared to ABR. The ALR BIC elicited by a 2,000 Hz tone burst showed a significant correlation with sentence recognition scores in both quiet and noise, as well as localization scores at 2,000 Hz. Other variables also demonstrated significant interrelationships.Conclusion: This study suggests that the ALR BIC elicited by a 2,000 Hz tone burst may be a key physiological component representing spatial hearing abilities in individuals with hearing loss. More robust conclusions can be drawn from future studies with larger sample sizes and more sophisticated designs.