Fei Chen

Dr. Fei Chen

orcid

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2019 in Physiological Measurement
Verified
Journal Article
Open access
PDF file
Haipeng LiuHaipeng Liu
Haipeng Liu
John AllenJohn Allen
John Allen
DZDingchang Zheng
Dingchang Zheng
FCFei Chen
Fei Chen
Respiratory rate (RR) is an important physiological parameter whose abnormality has been regarded as an important indicator of serious illness. In order to make RR monitoring simple to perform, reliable and accurate, many different methods have been proposed for such automatic monitoring. According to the theory of respiratory rate extraction, methods are categorized into three modalities: extracting RR from other physiological signals, RR measurement based on respiratory movements, and RR measurement based on airflow. The merits and limitations of each method are highlighted and discussed. In addition, current works are summarized to suggest key directions for the development of future RR monitoring methodologies.

1 November 2023 in Physiological Measurement
Verified
Journal Article
Open access
Peter CharltonPeter Charlton
Peter Charlton
John AllenJohn Allen
John Allen
Raquel BailónRaquel Bailón
Raquel Bailón
SBStephanie Baker
Stephanie Baker
JBJoachim A Behar
Joachim A Behar
TZTingting Zhu
Tingting Zhu
Photoplethysmography is a key sensing technology which is used in wearable devices such as smartwatches and fitness trackers. Currently, photoplethysmography sensors are used to monitor physiological parameters including heart rate and heart rhythm, and to track activities like sleep and exercise. Yet, wearable photoplethysmography has potential to provide much more information on health and wellbeing, which could inform clinical decision making. This Roadmap outlines directions for research and development to realise the full potential of wearable photoplethysmography. Experts discuss key topics within the areas of sensor design, signal processing, clinical applications, and research directions. Their perspectives provide valuable guidance to researchers developing wearable photoplethysmography technology.

5 March 2019 in Frontiers in Physiology
Verified
Journal Article
Open access
PDF file
VHVera Hartmann
Vera Hartmann
Haipeng LiuHaipeng Liu
Haipeng Liu
FCFei Chen
Fei Chen
QQQian Qiu
Qian Qiu
SHStephen Hughes
Stephen Hughes
DZDingchang Zheng
Dingchang Zheng
Introduction: Photoplethysmography (PPG) has been widely used to assess cardiovascular function. However, few studies have comprehensively investigated the effect of measurement site on PPG waveform characteristics. This study aimed to provide a quantitative comparison on this. Methods: Thirty six healthy subjects participated in this study. For each subject, PPG signals were sequentially recorded for 1 min from six different body sites (finger, wrist under (anatomically volar), wrist upper (dorsal), arm, earlobe, and forehead) under both normal and deep breathing patterns. For each body site under a certain breathing pattern, the mean amplitude was firstly derived from recorded PPG waveform which was then normalized to derive several waveform characteristics including the pulse peak time (Tp), dicrotic notch time (Tn), and the reflection index (RI). The effects of breathing pattern and measurement site on the waveform characteristics were finally investigated by the analysis of variance (ANOVA) with post hoc multiple comparisons. Results: Under both breathing patterns, the PPG measurements from the finger achieved the highest percentage of analyzable waveforms for extracting waveform characteristics. There were significant effects of breathing pattern on Tn and RI (larger Tn and smaller RI with deep breathing on average, both p < 0.03). The effects of measurement site on mean amplitude, Tp, Tn, and RI were significant (all p < 0.001). The key results were that, under both breathing patterns, the mean amplitude from finger PPG was significantly larger and its Tp and RI were significantly smaller than those from the other five sites (all p < 0.001, except p = 0.04 for the Tp of “wrist under”), and Tn was only significantly larger than that from the earlobe (both p < 0.05). Conclusion: This study has quantitatively confirmed the effect of PPG measurement site on PPG waveform characteristics (including mean amplitude, Tp, Tn, and RI), providing scientific evidence for a better understanding of the PPG waveform variations between different body sites.

23 October 2018 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
Syed Ghufran KhalidSyed Ghufran Khalid
Syed Ghufran Khalid
JZJufen Zhang
Jufen Zhang
FCFei Chen
Fei Chen
DZDingchang Zheng
Dingchang Zheng
Introduction. Blood pressure (BP) has been a potential risk factor for cardiovascular diseases. BP measurement is one of the most useful parameters for early diagnosis, prevention, and treatment of cardiovascular diseases. At present, BP measurement mainly relies on cuff-based techniques that cause inconvenience and discomfort to users. Although some of the present prototype cuffless BP measurement techniques are able to reach overall acceptable accuracies, they require an electrocardiogram (ECG) and a photoplethysmograph (PPG) that make them unsuitable for true wearable applications. Therefore, developing a single PPG-based cuffless BP estimation algorithm with enough accuracy would be clinically and practically useful. Methods. The University of Queensland vital sign dataset (online database) was accessed to extract raw PPG signals and its corresponding reference BPs (systolic BP and diastolic BP). The online database consisted of PPG waveforms of 32 cases from whom 8133 (good quality) signal segments (5 s for each) were extracted, preprocessed, and normalised in both width and amplitude. Three most significant pulse features (pulse area, pulse rising time, and width 25%) with their corresponding reference BPs were used to train and test three machine learning algorithms (regression tree, multiple linear regression (MLR), and support vector machine (SVM)). A 10-fold cross-validation was applied to obtain overall BP estimation accuracy, separately for the three machine learning algorithms. Their estimation accuracies were further analysed separately for three clinical BP categories (normotensive, hypertensive, and hypotensive). Finally, they were compared with the ISO standard for noninvasive BP device validation (average difference no greater than 5 mmHg and SD no greater than 8 mmHg). Results. In terms of overall estimation accuracy, the regression tree achieved the best overall accuracy for SBP (mean and SD of difference: −0.1 ± 6.5 mmHg) and DBP (mean and SD of difference: −0.6 ± 5.2 mmHg). MLR and SVM achieved the overall mean difference less than 5 mmHg for both SBP and DBP, but their SD of difference was >8 mmHg. Regarding the estimation accuracy in each BP categories, only the regression tree achieved acceptable ISO standard for SBP (−1.1 ± 5.7 mmHg) and DBP (−0.03 ± 5.6 mmHg) in the normotensive category. MLR and SVM did not achieve acceptable accuracies in any BP categories. Conclusion. This study developed and compared three machine learning algorithms to estimate BPs using PPG only and revealed that the regression tree algorithm was the best approach with overall acceptable accuracy to ISO standard for BP device validation. Furthermore, this study demonstrated that the regression tree algorithm achieved acceptable measurement accuracy only in the normotensive category, suggesting that future algorithm development for BP estimation should be more specific for different BP categories.

27 September 2016 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
YLYing-Hui Lai
Ying-Hui Lai
FCFei Chen
Fei Chen
SWSyu-Siang Wang
Syu-Siang Wang
XLXugang Lu
Xugang Lu
YTYu Tsao
Yu Tsao
CLChin-Hui Lee
Chin-Hui Lee
Objective: In a cochlear implant (CI) speech processor, noise reduction (NR) is a critical component for enabling CI users to attain improved speech perception under noisy conditions. Identifying an effective NR approach has long been a key topic in CI research. Method: Recently, a deep denoising autoencoder (DDAE) based NR approach was proposed and shown to be effective in restoring clean speech from noisy observations. It was also shown that DDAE could provide better performance than several existing NR methods in standardized objective evaluations. Following this success with normal speech, this paper further investigated the performance of DDAE-based NR to improve the intelligibility of envelope-based vocoded speech, which simulates speech signal processing in existing CI devices. Results: We compared the performance of speech intelligibility between DDAE-based NR and conventional single-microphone NR approaches using the noise vocoder simulation. The results of both objective evaluations and listening test showed that, under the conditions of nonstationary noise distortion, DDAE-based NR yielded higher intelligibility scores than conventional NR approaches. Conclusion and significance: This study confirmed that DDAE-based NR could potentially be integrated into a CI processor to provide more benefits to CI users under noisy conditions.

29 September 2022 in IEEE/ACM Transactions on Audio, Speech, and Language Processing
Verified
Journal Article
Open access
RZRyandhimas E. Zezario
Ryandhimas E. Zezario
SFSzu-Wei Fu
Szu-Wei Fu
FCFei Chen
Fei Chen
CFChiou-Shann Fuh
Chiou-Shann Fuh
HWHsin-Min Wang
Hsin-Min Wang
YTYu Tsao
Yu Tsao
This study proposes a cross-domain multi-objective speech assessment model, called MOSA-Net, which can simultaneously estimate the speech quality, intelligibility, and distortion assessment scores of an input speech signal. MOSA-Net comprises a convolutional neural network and bidirectional long short-term memory architecture for representation extraction, and a multiplicative attention layer and a fully connected layer for each assessment metric prediction. Additionally, cross-domain features (spectral and time-domain features) and latent representations from self-supervised learned (SSL) models are used as inputs to combine rich acoustic information to obtain more accurate assessments. Experimental results show that in both seen and unseen noise environments, MOSA-Net can improve the linear correlation coefficient (LCC) scores in perceptual evaluation of speech quality (PESQ) prediction, compared to Quality-Net, an existing single-task model for PESQ prediction, and improve LCC scores in short-time objective intelligibility (STOI) prediction, compared to STOI-Net, an existing single-task model for STOI prediction. Moreover, MOSA-Net can be used as a pre-trained model to be effectively adapted to an assessment model for predicting subjective quality and intelligibility scores with a limited amount of training data. Experimental results show that MOSA-Net can improve LCC scores in mean opinion score (MOS) predictions, compared to MOS-SSL, a strong single-task model for MOS prediction. We further adopt the latent representations of MOSA-Net to guide the speech enhancement (SE) process and derive a quality-intelligibility (QI)-aware SE (QIA-SE) approach. Experimental results show that QIA-SE outperforms the baseline SE system with improved PESQ scores in both seen and unseen noise environments over a baseline SE model.