Giovanni Volpato

Dr. Giovanni Volpato


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 March 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Yari ValeriYari Valeri
Yari Valeri
Paolo CompagnucciPaolo Compagnucci
Paolo Compagnucci
GVGiovanni Volpato
Giovanni Volpato
LLLara Luciani
Lara Luciani
ECEleonora Crepaldi
Eleonora Crepaldi
Michela CasellaMichela Casella
Michela Casella
There are no investigations about the outcomes of idiopathic PVC catheter ablation (CA) in athletes compared to the sedentary population. We conducted a prospective single-centre observational study. The primary and secondary procedural outcomes were the post-ablation reduction of premature ventricular contractions (PVCs) in an athletes vs. non-athletes group and in agonist vs. leisure-time athletes. The third was the evaluation of the resumption of physical activity and the improvement of symptoms in agonist and leisure-time athletes. From January 2020 to October 2022 we enrolled 79 patients with RVOT/LVOT/fascicular PVC presumed origin. The median percentage of decrease between the pre-procedure and post-procedure Holter monitoring in the non-athletes group was 96 (IQR 68–98) and 98 in the athletes group (IQR 92–99) (p = 0.08). Considering the athletes, the median percentage of decrease in the number of PVCs was 98 (IQR 93–99) and 98 (IQR 87–99), respectively, in leisure-time and agonistic athletes (p = 0.42). Sixteen (70%) leisure time and seventeen (90%) agonist athletes (p = 0.24) have resumed physical activity 3 months after PVC CA; among agonistic athletes, 59% have resumed competitive physical activity. Many leisure-time (88%) and agonist (70%) athletes experienced an improvement in symptoms after ablation. PVC CA was effective and safe in both groups, reducing symptoms and allowing a quick and safe return to sports activities in athletes.

22 March 2024 in Medicina
Verified
Journal Article
Open access
PDF file
MFMarco Fogante
Marco Fogante
GVGiovanni Volpato
Giovanni Volpato
PPPaolo Esposto Pirani
Paolo Esposto Pirani
FCFatjon Cela
Fatjon Cela
Paolo CompagnucciPaolo Compagnucci
Paolo Compagnucci
NSNicolò Schicchi
Nicolò Schicchi
The application of cardiac magnetic resonance (CMR) imaging in clinical practice has grown due to technological advancements and expanded clinical indications, highlighting its superior capabilities when compared to echocardiography for the assessment of myocardial tissue. Similarly, the utilization of implantable cardiac electronic devices (CIEDs) has significantly increased in cardiac arrhythmia management, and the requirements of CMR examinations in patients with CIEDs has become more common. However, this type of exam often presents challenges due to safety concerns and image artifacts. Until a few years ago, the presence of CIED was considered an absolute contraindication to CMR. To address these challenges, various technical improvements in CIED technology, like the reduction of the ferromagnetic components, and in CMR examinations, such as the introduction of new sequences, have been developed. Moreover, a rigorous protocol involving multidisciplinary collaboration is recommended for safe CMR examinations in patients with CIEDs, emphasizing risk assessment, careful monitoring during CMR, and post-scan device evaluation. Alternative methods to CMR, such as computed tomography coronary angiography with tissue characterization techniques like dual-energy and photon-counting, offer alternative potential solutions, although their diagnostic accuracy and availability do limit their use. Despite technological advancements, close collaboration and specialized staff training remain crucial for obtaining safe diagnostic CMR images in patients with CIEDs, thus justifying the presence of specialized centers that are equipped to handle these type of exams.

8 April 2024 in Medicina
Verified
Journal Article
Open access
PDF file
MAMichele Alfieri
Michele Alfieri
FGFederico Guerra
Federico Guerra
CLCarla Lofiego
Carla Lofiego
MFMarco Fogante
Marco Fogante
GCGiuseppe Ciliberti
Giuseppe Ciliberti
Michela CasellaMichela Casella
Michela Casella
Background and Objectives: Cardiac magnetic resonance (CMR) imaging has become an essential instrument in the study of cardiomyopathies; it has recently been integrated into the diagnostic workflow for cardiac amyloidosis (CA) with remarkable results. An additional emerging role is the stratification of the arrhythmogenic risk by scar analysis and the possibility of merging these data with electro-anatomical maps. This is made possible by using a software (ADAS 3D, Galgo Medical, Barcelona, Spain) able to provide 3D heart models by detecting fibrosis along the whole thickness of the myocardial walls. Little is known regarding the applications of this software in the wide spectrum of cardiomyopathies and the potential benefits have yet to be discovered. In this study, we tried to apply the ADAS 3D in the context of CA. Materials and Methods: This study was a retrospectively analysis of consecutive CMR imaging of patients affected by CA that were treated in our center (Marche University Hospital). Wherever possible, the data were processed with the ADAS 3D software and analyzed for a correlation between the morphometric parameters and follow-up events. The outcome was a composite of all-cause mortality, unplanned cardiovascular hospitalizations, sustained ventricular arrhythmias (VAs), permanent reduction in left ventricular ejection fraction, and pacemaker implantation. The secondary outcomes were the need for a pacemaker implantation and sustained VAs. Results: A total of 14 patients were deemed eligible for the software analysis: 8 patients with wild type transthyretin CA, 5 with light chain CA, and 1 with transthyretin hereditary CA. The vast majority of imaging features was not related to the composite outcome, but atrial wall thickening displayed a significant association with both the primary (p = 0.003) and the secondary outcome of pacemaker implantation (p = 0.003). The software was able to differentiate between core zones and border zones of scars, with the latter being the most extensively represented in all patients. Interestingly, in a huge percentage of CMR images, the software identified the highest degree of core zone fibrosis among the epicardial layers and, in those patients, we found a higher incidence of the primary outcome, without reaching statistical significance (p = 0.18). Channels were found in the scar zones in a substantial percentage of patients without a clear correlation with follow-up events. Conclusions: CMR imaging plays a pivotal role in cardiovascular diagnostics. Our analysis shows the feasibility and applicability of such instrument for all types of CA. We could not only differentiate between different layers of scars, but we were also able to identify the presence of fibrosis channels among the different scar zones. None of the data derived from the ADAS 3D software seemed to be related to cardiac events in the follow-up, but this might be imputable to the restricted number of patients enrolled in the study.

24 May 2024 in EP Europace
Verified
Journal Article
Open access
FCF Cardinali
F Cardinali
Francesca CampanelliFrancesca Campanelli
Francesca Campanelli
GVGiovanni Volpato
Giovanni Volpato
Paolo CompagnucciPaolo Compagnucci
Paolo Compagnucci
QPQ Parisi
Q Parisi
Antonio Dello RussoAntonio Dello Russo
Antonio Dello Russo
Background: Pulsed Field ablation (PFA) has recently emerged as a treatment strategy for patients with atrial fibrillation (AF) and early studies showed promising procedural data and durable pulmonary vein isolation (PVI). However, Very High-Power Short-Duration ablation (VHPSD) has previously reported good efficiency and mid-term outcomes, and only a few works compared these two procedures, especially in patients with persistent AF. Objective: Our aim is to compare these different modalities of transcatheter ablation in patients with persistent AF, focusing mainly on some procedural aspects, safety and efficacy. Methods: We performed a retrospective observational study enrolling all consecutive patients with persistent AF from September 2021 to May 2023 undergoing transcatheter ablation with PFA or VHPSD. In the first group, PVI was achieved by 2kV pulses with eight applications to each vein using both catheter configurations, while isolation of the posterior wall of the left atrium was achieved by applications through the only "flower" configuration; additional lesions were then added at the operator's discretion. In the second group, PVI was achieved by delivering 90W radiofrequency pulses for 4 seconds in the posterior portions of the left atrium and 50W pulses in the anterior region of the pulmonary veins; additional lesions were occasionally applied. All patients received general anaesthesia or deep sedation with fentanyl and dexmedetomidine. Results: A total of 79 patients were included, n = 24 (30%) in the PFA group and N = 55 (70%) in the VHPSD one: early persistent AF (n= 2 [8,3%]; N = 7 [12,7%]), persistent AF (n= 17 [70,8%]; N = 36 [65,5%]), long-standing persistent AF (n= 5 [20,8%]; N = 12 [21,8%]). The two populations showed similar clinical features: CHA2DS2-VASc (median value 3 [0-6] in PFA vs 2 [0-6] in VHPSD, p = 0,10), indexed left atrial volume (mean value 42,6 ml/m² in PFA vs 42,4 ml/m² in VHPSD, p = 0,07) and EF (mean value 55,4% in PFA vs 54,8% in VHPSD, p = 0,33). PVI was successfully achieved in all patients. Nevertheless, the PFA group was associated with shorter procedural duration (92,1 ± 36,9 vs 134,2 ± 36,1 minutes, p = 0,00001) but longer fluoroscopy time (25,5 ± 9,3 vs 17,4 ± 11,5 minutes, p = 0,001); it also showed a lower rate of minor complications (n = 1 [4,2%] vs N = 3 [5,5%], p = 0,057), even though serious complications were not observed in either group. After a median follow-up of 14 (9-26) months, n = 19 [79.2%] in the PFA and N = 43 [78.2%] in the VHPSD population were free of any atrial arrhythmia (p = 0,92). Conclusion: PFA allows faster procedures, representing a major advantage for the operator and the patient, who is at lower risk of peri-procedural complications. On the other hand, VHPSD correlates with shorter fluoroscopy times, reducing exposure to ionizing radiation. Finally, the two procedures show similar mid-term efficacy in terms of recurrence-free time.

14 January 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
Yari ValeriYari Valeri
Yari Valeri
Paolo CompagnucciPaolo Compagnucci
Paolo Compagnucci
GVGiovanni Volpato
Giovanni Volpato
LLLara Luciani
Lara Luciani
ECEleonora Crepaldi
Eleonora Crepaldi
Michela CasellaMichela Casella
Michela Casella
There are no investigations about the outcomes of idiopathic PVCs catheter ablation (CA) in athletes compared to sedentary population. We conducted a prospective single-centre observational study. The primary and secondary procedural outcomes were premature ventricular contractions (PVCs) post-ablation reduction in athletes vs. non-athletes group and in agonist vs. leisure-time athletes. The third was the evaluation of the resumption of physical activity and the improvement of symptoms in agonist and leisure-time athletes. From January 2020 to October 2022 we enrolled 79 patients with RVOT/LVOT/fascicular PVC presumed origin. The median percentage of decrease between the pre-procedure and post-procedure Holter monitoring in non-athletes group was 96 (IQR 68 – 98) and 98 in athletes group (IQR 92 – 99) (p=0,08). Considering the athletes, the median percentage of decrease in PVCs number was 98 (IQR 93-99) and 98 (IQR 87-99) respectively in leisure-time and agonistic athletes (p=0,42). Sixteen (70%) leisure time and 17 (90%) agonist athletes (p=0,24) have resumed physical activity 3 months after PVCs CA; among agonistic athletes, 59% have resumed competitive physical activity. Much of leisure-time (88%) and agonist (70%) athletes experienced an improvement in symptoms after ablation. PVC CA was effective and safe in both groups, reducing symptoms and allowing a quick and safe return to sports activities in athletes.

24 May 2024 in EP Europace
Verified
Journal Article
Open access
Francesca CampanelliFrancesca Campanelli
Francesca Campanelli
FCF Cardinali
F Cardinali
GVGiovanni Volpato
Giovanni Volpato
Paolo CompagnucciPaolo Compagnucci
Paolo Compagnucci
LCLaura Cipolletta
Laura Cipolletta
Antonio Dello RussoAntonio Dello Russo
Antonio Dello Russo
Background: The newly introduced non-thermal pulsed field ablation (PFA) is a promising technology for catheter ablation (CA) of atrial fibrillation (AF) with high acute success rates and good safety features. However studies have shown that very high power short duration (VHPSD) ablation is also highly effective and fast with potentially less arrhythmia recurrence compared to conventional radiofrequency ablation. Data comparing this two methods are lacking Objective: The aim of this study is to compare two source of energy used for CA of AF in terms of procedural, clinical and outcome data Methods: We conduced a retrospective observational study enrolling all patients (pts) from september 2021 to may 2023 who underwent CA of AF with PFA system and VHPSD. In the PFA group pulmonary veins isolation (PVI) was obtained using 2KV with eight application each vein, posterior wall isolation (PWI) of left atrium (LA) was obtained with application in the flower configuration of the catheter and then additional lesion were deployed at the operator’s discretion. In the VHPSD group the encircling of PV was obtained with 90W for 4 seconds radiofrequency pulses in posterior portions of the LA including LA PW, whereas 50W with ablation index target of 500 was used in the anterior portions of the PV and additional lesions. General anesthesia or deep sedation was carried out in all pts Results: A total of 205 pts were included, n = 86 (42%) in the PFA group and N = 119 (58%) in the VHPSD group: paroxysmal (n = 62[72%], N = 64[54%]), persistent (n = 19[22%], N = 43[36%]), long standing persistent (n = 5[5%], N = 10[8%]). PVI was successful in all pts and additional lesions were delivered in n = 26 (30%) in PFA group and N = 76 (64%) in HVPSD group, mostly at the PW (n = 24[92%]; N = 50[66%]). The PFA group revealed a shorter procedura duration (80 ± 29 min vs 108 ± 39 min; p = 0,00001) but longer fluoroscopic time (21 ± 8 min vs 14 ± 10 min; p = 0,00001). The VHPSD group revealed more complications (N = 7[6%] vs n = 3[3%]) but without statistically significant difference (p = 0,43), the most frequent in the PFA group was vascular access complications instead in the VHPSD group was post-procedural pericarditis. Only one patient in VHPSD group had major complication with a post-procedural stroke but without residual neurological deficits. At follow-up after median of 14 (26-6) months, n = 61 pts in the PFA group (71%) and N = 91 in the VHPSD group (76%) were free from atrial arrhythmia (p = 0,79). In both group 7 pts recurrenced as atypical atrial flutter (n = 7[28%] PFA; N = 7[25%] VHPSD; p = 0,061) Conclusion: PFA and VHPSD are effective and safe to CA of AF with comparable arrhythmia recurrenses. However procedure duration with PFA is significantly shorter and therefore may be of potential benefit in particular for elderly and frail pts. Further research, including randomized controlled trials, is needed to validate and compare these techniques more comprehensively