OJONG Elias OJONG

Dr. OJONG Elias OJONG


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 March 2024 in Advances in Science and Technology
Verified
Conference Paper
Closed access
PDF file
OOOJONG Elias OJONG
OJONG Elias OJONG
VEVictor Ita Etim
Victor Ita Etim
GAGrace Esu Ejemot Aquah
Grace Esu Ejemot Aquah
RURomokere Isotuk Uzono
Romokere Isotuk Uzono
A design of 225[metric tons per year] of an acetone plant from isopropanol alcohol (IPA) was developed. The design considers the fundamental principles of mass and energy balance to size the units of the acetone plant, particularly the Gibbs reactor, separator, absorber, and distillation columns. The beauty of plant design is to account for the material and energy conservation principles interactions and specify the dimensions of the main unit operations of the plant. The HYSYS simulation software was used to design the acetone plant, and the properties of the fluid were used to manually size the plant. The four components resulting from the reaction of IPA and water (acting as a catalyst) to obtain acetone and hydrogen are 2-propanol, acetone, hydrogen, and water. The balance of how these components is heated, reacted, cooled, separated, absorbed, and distilled of acetone from a mixture of IPA/water is shown logically with sketches for the material and energy values of the key unit operations of the plant. The mechanical design of the units was performed to determine the thickness of the columns. In addition, a cost-plus-economic analysis of acetone was carried out. The results indicate that, the sizing of the units gave the following results viz: manually, the reactor with sized 5.4 [m3], 1.56[m] and 2.34[m] as the diameter and height respectively, the separator was sized to 1.78[m] diameter and 2.67[m] height with 6.631[m3] volume, the absorber column gave 0.085[m] diameter, 1.1[m] height, and the distillation column design values are 0.202[m] column diameter, 10.8[m] height and the weir length of 0.154[m]. The overall cost, including the cost of utilities for the entire plant, was [$]7.792million; the equivalent annual operating cost was [$]4.408million; and the thicknesses of the reactor, separator, absorber, and dilation columns are respectively 2.42[mm], 11.71[mm], 1.99[mm] and 3.36[mm]. Validation of the manual design was carried out with HYSYS simulation results, which indicated that the design models were reliable and could be adopted for the design because the deviation values on the specifications of the units are small ranges from 0.04 – 0.4. The result of the design showed that acetone production from the IPA route was recommended and that the HYSYS simulation formed part of the entire design of the acetone plant.

29 February 2024 in Pure and Applied Chemistry
Verified
Journal Article
Closed access
OOOJONG Elias OJONG
OJONG Elias OJONG
OWOmeke Chimene Wosu
Omeke Chimene Wosu
AEAguma Emenike
Aguma Emenike
Paschal Ateb UbiPaschal Ateb Ubi
Paschal Ateb Ubi
The research considers the design and simulation of 30 000 tons per year of cumene plant using Aspen HYSYS as the simulation tool. The feed (material content) used is the characterized natural gas from Utorogu Gas Field with composition of 0.9019 methane, 0.0694 ethane, 0.0209 propane, 0.00361 n-butane, 0.00414 i-butane, 0.00005 n-pentane and 0.00007 i-pentane. The cumene plant consist of the cryogenic distillation column, de-hydrogenator (Continuous Stirred Tank Reactor), Alkylator (Plug Flow Reactor), storage tanks, separators, pumps, heat exchanger and mixers. The size/design models of basic plant units such as de-hydrogenator, alkylator, separators, storage tanks and distillation column were developed using the principles of mass and energy balance. The result of design or size specifications in terms of equipment diameter of basic plant units obtained from HYSYS simulation are 0.8 m and 0.319 m for the cryogenic and cumene columns; 1.931 m, 2.244 m and 1.366 m for the propane, propene and cumene storage tanks; 1.868 m and 2.076 m for the de-hydrogenator and alkylator; 1.931 m and 2.146 m for propene and cumene separators respectively. The power or capacity of propane and propene pumps configured in the plant are 0.02 kW and 0.005 kW respectively. The result of the reactor and distillation column thickness specification to withstand corrosion, pressure or stress during plant operation in terms of cylindrical shell and ellipsoidal doomed head are 17.36 mm and 4.31 mm respectively. The economic evaluation (overall cost) including the cost of utilities, catalyst, operating, and maintenance for entire plant is $ 3.004 M.

15 March 2024 in Advances in Science and Technology
Verified
Conference Paper
Closed access
PDF file
WDWilson Dadet
Wilson Dadet
OOOJONG Elias OJONG
OJONG Elias OJONG
KDKenneth Kekpugile Dagde
Kenneth Kekpugile Dagde
The design and energy simulation of carbon dioxide captured process through which Liquefied Natural Gas (LNG) plant has been achieved using Monoethanolamine (MEA) as a solvent. An optimization and technical parameter study for which CO2 captured process (CCP) from the flue gas of a natural gas liquefaction plant was formed based on absorption/desorption process with MEA solutions, using ASPEN HYSYS. This optimization was aimed at reducing the energy requirement for solvent regeneration, by investigating the effects of CO2 removal percentage, stripper operating pressure and cooling water flow. Also, the study showed that major energy savings can be realized by optimizing the lean solvent loading the CO2 transmission phase as well as the stripper operating pressure through the compression and pumping process in the CCP. The specifications, equipment thickness, and cost models were developed based on the principles of conservation of mass and energy, and thermodynamic principles. Aspen HYSYS simulation was carried out on the entire CCP using flue gas of composition carbon dioxide (8.7%), water (17.8%), nitrogen (73.3%), oxygen (0.2%), sulphur dioxide (0.0017%), and nitrox (0.0097%) with input process conditions of pressure 101.6kPa, temperature 150°C and flow rate of 500tons per day. During the study, a minimum thermal energy requirement was found at a lean MEA loading of 0.13, using a 40 wt.% MEA solution and a stripper operating pressure of 130 kPa, resulting in a thermal energy requirement of 1.025 GJ/ton CO2. Recoveries were done at 75%, 80%, 85%, 90%, 95% and 99% of the simulation process. Suitable correlation models were developed relating to the energy consumption rate per stripper operating pressure and specific thermal energy consumption per solvent flow rate with percentage recoveries. When compared to the simulation result, minimum errors of 0.05% and 2% respectively were obtained. The relationship between the compressor power and CO2 recovery was linear at a minimum power consumption of 130 kW at 75% recovery while a maximum consumption of 175 kW was obtained at 99% recovery. It was observed that the specific thermal energy consumption per solvent is linearly related to the extent of recoveries, as higher energy was required to recover more CO2. Compression and pumping with supercritical liquefaction taking the CO2 above critical pressure of 100bar through three compression sections, inter-cooled to 40°C with water at ambient conditions. Thus, enhancing the high efficiency of the system. The HYSYS simulation results, the process conditions and the characterized flue gas were used for the manual computations to determine the efficiency of the CO2, the size and specifications of the absorber and the amine regenerator columns. The HYSYS results obtained from the simulation of the entire CCP gave a recovery of 99% of the CO2 removed from its initial content (8.7%). The energy and thermodynamic analysis of the CCP carried out gave result with the cycle efficiency of 94.92%, an efficient process with 20% energy reduction due to compression and pumping action done by incorporating pumps in the process. The results of the specifications from the material balance of the absorber and amine regenerator columns gave the diameter, height, and number of trays of these units in the CCP as, 2.215m; 10m, and 25, and 2m; 6m, and 20 respectively. While, the thickness results for the ellipsoidal doomed head and cylindrical shell of the absorber and amine regenerator columns were respectively given as, 8.27mm and 8.26mm, and 81.17mm and 78.33mm. The overall cost, including the cost of utilities, for the entire plant was obtained to be $19.629m.

1 January 2025 in Gamification and Augmented Reality
Verified
Journal Article
Open access
PDF file
OOOJONG Elias OJONG
OJONG Elias OJONG
A geothermal groundwater heating and cooling plant consisting of a heat pump and heat exchanger has been designed. Geothermal heating and cooling systems play a crucial role in the decarbonization of the environment, helping to prevent global warming and promote energy savings due to the reduced energy required to power the plant, which in turn generates more geothermal energy for the heating and cooling needs of the fertilizer company. This study considered Eleme Fertilizer as a case study for the scaled-up and installation of the prototype designed of the geothermal groundwater heating and cooling plant. Both manual and software simulation designs were conducted based on material and energy balance principles. Error analysis and deviations were used to validate the design results. The results of the plant's unit design showed that the power drive, overall efficiency, and coefficient of performance for heating and cooling were 354.1 kW, 402%, and 2.82 & 1.05, respectively. For the heat exchanger, design type 10-E-01, the values for heat duty, overall heat transfer coefficient, exchanger area, and tube pressure drop were 309.5 kW, 0.2104 kW/m²°C, 60.32 m², and 390 MPa, respectively. Error analysis conducted on the design work showed negligible values of RMSE (0.02, 0.025, 20 and 0.656) and deviation (0.014, 0.05, 0.05, 0.002) for coefficient of performance of heating and cooling, heat pump efficiency and the drive power of the plant respectively. The values obtained from the design of the units in the geothermal plant were reasonable and are thus recommended for academic and industrial applications

19 February 2026 in Advanced Materials Research
Verified
Journal Article
Closed access
PDF file
OOOJONG Elias OJONG
OJONG Elias OJONG
OAOdey David Adoga
Odey David Adoga
UAUloma Catherine Anaba
Uloma Catherine Anaba
SSSilas Shamaye Samuel
Silas Shamaye Samuel
RARaymond Rowland Ana
Raymond Rowland Ana
OOOdey Osha
Odey Osha
Chitosan and clay materials of 50:50 ratio, produced and characterized from periwinkle shells and clay soil, was applied to capture CO 2 from gas mixture at elevated temperatures (50 O C to 250 O C) in a column bed, packed with the particles of dimension length 1.5 (m), and inner diameter 0.02 (m). The composition of gas mixture are 0.003, 0.002, 0.05, 0.15, 0.02, and 0.76 for CH 4, C 2 H 6, H 2, CO 2, H 2 O vapour, and N 2, respectively at condition of pressure 49 (kPa), temperature 250 O C, and flow rate 75 (L/min) from exhaust column into the column bed for adsorption process. The kinetic and isotherm models are adopted and simulations performed from the experimental data to determine suitable adsorption parameters for the process. Also, Aspen plus and statistical optimization tool to simulate the experimental data are utilized to determine the optimal yield and conditions of factors. The coefficient of determination of 0.992 showed that the quadratic model is best suitable for the combination of parameters and fitted well, while the optimization result gave significant difference among the bed height, temperature and time and their interactions. The result revealed that the adsorption process best followed Elovich kinetic and fitted well in the Freundlich multilayer adsorption isotherm with parameters 0.0187 (mg/g.hr), 175.932, and 1.5 for the kinetic constant, adsorption constant, and intensity respectively. The root means square errors and deviation values gave negligible values of 0.166; 0.045, and 0.0345; 0.0094 for the design/simulation; optimization models applied, when compared to the experimental data. The regression results of the factors analysis showed that the model R 2 of 0.995 is more reliable and fitted well than the modified R 2 of 0.985 and the estimated R 2 of 0.965 . The central composite design for the optimization of the process gave maximum yield of 0.9411 at suitable combine time and temperature factors effect. Aspen plus simulation result gave yield of 0.9831 CO 2 removed from optimal conditions of time, temperature, and bed height of 2.8 (hrs), 155.6°C, and 3.44 (cm) respectively. It was noticed that N 2 , CH 4 , C 2 H 6 , and water vapour were removed from the gas mixture of yields 0.9972, 0.9832, 0.9831, and 0.9947 respectively.

3 February 2025 in Advances in Science and Technology
Verified
Conference Paper
Closed access
PDF file
OOOJONG Elias OJONG
OJONG Elias OJONG
PBPreniyobo Diepriye Benibo
Preniyobo Diepriye Benibo
FAFidelis Ibiang Abam
Fidelis Ibiang Abam
SSSilas Shamaye Samuel
Silas Shamaye Samuel
Chitosan/clay materials derived from periwinkle shells and clay soil at a 50:50 ratio were prepared as adsorbents, characterized, and used for the adsorption of CO2 from flue gas at elevated temperatures (500°C - 5000°C) in a fixed bed column (1.5 m in length and 0.02 m in internal diameter). The flue gas, with a composition of Methane (0.003), Ethane (0.002), Hydrogen (0.05), CO2 (0.15), Water Vapor (0.02), and Nitrogen (0.76), at a pressure of 49 KPa, a temperature of 5000°C, and a flow rate of 75 L/min from the exhaust tank, entered the fixed bed column for the adsorption process, where the adsorbent had already been placed. Fourier Transform Infrared spectroscopy revealed the presence of halogen, alcohol, nitro, and amine compounds in the nanoparticles, indicating a strong affinity for CO2 particles in the flue gas. Additional analysis showed the presence of elements (Ca, Si, Al, and Sr) in significant compositions (0.470, 0.202, 0.186, and 0.092, respectively), suggesting that the adsorbent was resistant to high temperatures. X-ray diffraction analysis of the adsorbent identified Ca(OH)₂, CaCO₃, and TiO₂ with compositions of 0.78, 0.19, and 0.026, respectively, further confirming the strong affinity of the adsorbent for CO2. Surface morphology analysis revealed that the adsorbent’s surface was rough and contained a variety of pores or holes with different capacities, indicating that more CO2 was captured and accommodated within the surface. Thermal analysis using the Barrett-Joyner-Halenda method showed that the adsorbent could withstand high temperatures of up to 9000°C. At this temperature, the adsorbent accounted for only about 18% of the material that entered the fixed bed column for adsorption, but 100% of it could remain active within the temperature range of 0°C - 3000°C. The characterization of the adsorbent showed that a pore width of 5.283 nm, a pore diameter of 2.64 nm, a micropore surface area of 434.7 m²/g, a pore volume of 0.202 cc/g, and a porosity of 56.73% were the optimal values for the adsorbent. Finally, it was revealed that 95% of CO2 was adsorbed at optimal conditions within the temperature range of 500°C - 3500°C, time range of 0.5 - 5 hours, and bed height range of 1 - 6 cm.