Aims: Dual-mobility (DM) components are increasingly used to prevent and treat dislocation after total hip arthroplasty (THA). Intraprosthetic dissociation (IPD) is a rare complication of DM that is believed to have decreased with contemporary implants. This study aimed to report incidence, treatment, and outcomes of contemporary DM IPD.Methods: A total of 1,453 DM components were implanted at a single academic institution between January 2010 and December 2021: 695 in primary and 758 in revision THA. Of these, 49 presented with a dislocation of the large DM head and five presented with an IPD. At the time of closed reduction of the large DM dislocation, six additional IPDs occurred. The mean age was 64 years (SD 9.6), 54.5% were female (n = 6), and mean follow-up was 4.2 years (SD 1.8). Of the 11 IPDs, seven had a history of instability, five had abductor insufficiency, four had prior lumbar fusion, and two were conversions for failed fracture management.Results: The incidence of IPD was 0.76%. Of the 11 IPDs, ten were missed either at presentation or after attempted reduction. All ten patients with a missed IPD were discharged with a presumed reduction. The mean time from IPD to surgical treatment was three weeks (0 to 23). One patient died after IPD prior to revision. Of the ten remaining hips with IPD, the DM head was exchanged in two, four underwent acetabular revision with DM exchange, and four were revised to a constrained liner. Of these, five (50%) underwent reoperation at a mean 1.8 years (SD 0.73), including one additional acetabular revision. No patients who underwent initial acetabular revision for IPD treatment required subsequent reoperation.Conclusion: The overall rate of IPD was low at 0.76%. It is essential to identify an IPD on radiographs as the majority were missed at presentation or after iatrogenic dissociation. Surgeons should consider acetabular revision for IPD to allow conversion to a larger DM head, and take care to remove impinging structures that may increase the risk of subsequent failure.Cite this article: Bone Joint J 2024;106-B(5 Supple B):98–104.
Background/Objectives: Diagnostic evaluation and management of nontraumatic osteonecrosis of the femoral head (ONFH) vary substantially. This systematic review was conducted to inform development of the Association Research Circulation Osseous (ARCO) clinical practice guideline for diagnosis and treatment of ARCO stages I to III ONFH. Methods: We searched MEDLINE, EMBASE, Web of Science, SCOPUS, Global Index Medicus, and the Cochrane Library for studies evaluating imaging modalities and treatments for adult ONFH. We assessed risk of bias using the QUADAS-2, the ROB-2, and the ROBINS-I tools; conducted meta-analyses using random-effects regression; and evaluated certainty of evidence using GRADE methodology. Results: Among 36 included studies, 18 addressed diagnostic test accuracy and 18 addressed comparative effectiveness of treatments. Magnetic resonance imaging (MRI) demonstrated the highest pooled sensitivity (0.91; 95% confidence interval (CI), 0.87 to 0.94) and specificity (0.96; 95% CI, 0.87 to 0.99) for ONFH diagnosis. Bone marrow edema and grade 2+ joint effusion on MRI differentiated symptomatic versus asymptomatic disease. Computed tomography and MRI better detected subchondral fractures than plain radiography. Very low-grade evidence suggested lower rates of femoral head collapse with core decompression plus bone marrow concentrate compared with core decompression alone (pooled relative risk [RR], 0.55; 95% CI, 0.36 to 0.83), and with vascularized versus non-vascularized bone grafting (RR, 0.35; 95% CI, 0.14 to 0.84) over a ≤5-year follow-up. Based on three non-comparative case series, osteotomies might have a lower risk of collapse over a 10- to 20-year follow-up, but this needs to be evaluated in future comparative research. Inconsistent outcome reporting hindered treatment outcome pooling. There were no comparative studies that evaluated observation only versus intervention in asymptomatic disease or strategies for monitoring treatment response. Conclusions: Evidence supporting optimal imaging modalities and early joint-preserving interventions remains limited and predominantly observational, underscoring the need for high-quality comparative studies with consistently defined core outcomes to guide clinical decision-making.
Background: Total hip arthroplasty (THA) effectively restores mobility, reduces pain, and enhances the quality of life of patients of all ages. Despite its benefits, concerns regarding the long-term effects of high-impact activities and sports on implant longevity require further study. This study investigated the effect of activity level on long-term radiographic wear of highly cross-linked polyethylene (HXLPE) in young patients undergoing THA. Methods: Between 1999 and 2008, 785 patients (909 hips) aged ≤50 underwent primary THA using first-generation HXLPE liners from 4 different vendors with either metal or ceramic heads. Functional activity and participation questionnaires, including the Hip Injury and Osteoarthritis Outcome Score (HOOS Jr), University of California Los Angeles (UCLA) activity scale, and High-Activity Arthroplasty Score (HAAS), were surveyed in 2018 to 2019. The response rate was 44%. Radiographic linear wear rates were measured using the ROMAN software in patients who had completed questionnaires and had radiographs taken at least 10 years apart, leaving a final cohort of 249 patients (284 hips). Multivariate analyses were performed to determine the relationship between HXLPE wear rates and activity scores. Results: At the time of the survey, approximately 10% of the patients performed high-impact activities not-recommended by consensus guidelines. The HXLPE linear wear rate was 0.036 mm/year (SD: 0.026). Patients with higher activity levels, as measured on the continuous UCLA/HAAS activity scale, did not exhibit increased wear (β = -0.0009; p = 0.31). Stair climbing was correlated with increased wear rates (β = 0.0066; p = 0.004), whereas walking (β = 0.0005; p = 0.66) and running (β = 0.0017; p = 0.30) were not significantly correlated. Patients performing nonrecommended activities did not show increased wear rates compared with those performing recommended activities (β = 0.0063; p = 0.19). Conclusions: Linear wear rates of first-generation HXLPE were not related to functional activity or participation in high-impact activities. Future research should include longitudinal assessments of activity levels and data on other potential complications related to high-impact sports to provide robust evidence regarding recommended activity level postoperatively. Level of Evidence: Level III, Retrospective Comparative Study. See Instructions for Authors for a complete description of levels of evidence.
Despite growing interest, artificial intelligence (AI) applications in shoulder and elbow surgery remain underdeveloped. While adoption is accelerating and shows promise in addressing complex clinical problems, substantial technical and clinical barriers persist. Collaborative research may be relevant for generating high-quality datasets and more robust, generalizable, and clinically relevant algorithms. This study aimed to 1) analyze trends in AI research productivity and impact, 2) map collaboration patterns among affiliations and regions, and 3) assess the relationship between affiliation-based collaboration and research outcomes. We conducted a bibliometric analysis of Scopus-indexed articles published between January 2000 and November 2024, focusing on peer-reviewed studies involving AI applications in shoulder or elbow surgery. Data collected included number of publications, citation metrics, author affiliations, and index keywords. These variables were used to calculate composite metrics and to examine the geographic distribution of research and collaboration patterns using network analysis. Two linear regression models assessed the relationship between affiliation-based collaborations and publication volume and citation impact. Of 181 identified scholarly documents, 119 met eligibility criteria. These articles were published across 63 journals and cited a total of 1,519 times. The Journal of Shoulder and Elbow Surgery contributed the highest number of articles (n = 20), while Acta Orthopaedica had the highest average citations per article (n = 310), although in a single article. The annual publication rate increased rapidly after 2014, peaking at 49 in 2024. A small group of affiliations disproportionately influenced output and citations. Collaboration networks were sparse (density 0.03) yet showed distinct geographic clusters. Most research output originated from the United States (48%), followed by South Korea (12%) and China (8%). A total of 1,010 collaborations were identified among 260 affiliations. The network showed low density (0.03) but high modularity (0.81), indicating sparse overall connectivity yet tightly clustered communities. Regression models indicated that each additional collaboration established between affiliations was associated with 5 more publications (R2 = 1.0) and increased average citations per article by 0.2 (R2 = 0.77). Affiliation-based collaboration was strongly associated with both the volume and citation impact of AI research in shoulder and elbow surgery. Strengthening and expanding these networks may enhance global research participation, foster innovation, and improve the clinical applicability of future work.