Adriana Burlibasa

Mrs. Adriana Burlibasa


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 July 2026 in Electricity
Verified
Journal Article
Open access
PDF file
Marin George-AndreiMarin George-Andrei
Marin George-Andrei
Marian GaiceanuMarian Gaiceanu
Marian Gaiceanu
ABAdriana Burlibasa
Adriana Burlibasa
SESilviu Epure
Silviu Epure
CVCiprian Vlad
Ciprian Vlad
GPGeorge Petrea
George Petrea
This paper presents a low-cost embedded monitoring system for real-time RMS voltage and RMS current acquisition in three-phase electrical networks. The proposed architecture is based on distributed Arduino Nano acquisition nodes equipped with ACS712 Hall-effect current sensors and isolated voltage transformers, while a Raspberry Pi 4 Model B is used as a centralized data acquisition and processing unit through the I2C communication protocol. The embedded acquisition nodes implement timer-controlled analog signal sampling using the internal 10-bit ADC of the ATmega328P microcontroller, allowing real-time acquisition of electrical waveforms for RMS computation. Unlike conventional low-cost IoT electrical monitoring systems focused mainly on basic parameter visualization and wireless communication, the proposed platform emphasizes synchronized three-phase RMS monitoring and experimental validation accuracy under real operating conditions. The proposed monitoring architecture is experimentally benchmarked against a FLUKE 435 professional power quality analyser used as a high-accuracy reference instrument. Experimental results demonstrate that the proposed low-cost embedded architecture can provide RMS voltage and RMS current measurements with acceptable accuracy for educational applications, experimental electrical platforms, and distributed IoT-based monitoring systems. The presented system does not aim to implement a fully IEC 61000-4-30-compliant power quality analyser but rather to validate the feasibility of low-cost embedded RMS monitoring architectures for real-time electrical applications.

19 April 2026 in Sensors
Verified
Journal Article
Open access
PDF file
ABAdriana Burlibasa
Adriana Burlibasa
SESilviu Epure
Silviu Epure
MCMihai Culea
Mihai Culea
CDCristinel Radu Dache
Cristinel Radu Dache
CLCristian Lungu
Cristian Lungu
CVCiprian Vlad
Ciprian Vlad
Accurate time synchronization is essential in distributed electrical signal monitoring, where phase coherence and event correlation depend on precise timing agreement between acquisition nodes. Conventional approaches often rely on a single synchronization source, typically internet-based Network Time Protocol (NTP) or GPS-disciplined clocks, which is impractical in isolated, offline, or cost-sensitive scenarios. This paper introduces an autonomous offline synchronization architecture for multi-node monitoring systems built on Raspberry Pi 5 (RPI5) platforms connected to a private Ethernet network. Instead of depending on one timing method, the system integrates several complementary mechanisms: battery-backed RTC persistence via the J5 interface, deterministic orchestration through systemd services, automated boot time recovery, chrony-managed NTP discipline, and Precision Time Protocol (PTP) hardware timestamping using PTP Hardware Clock (PHC). Synchronization performance is validated through continuous multi-day measurements of long-term stability, inter-node phase coherence, and short-term jitter. Controlled power-loss scenarios are also included to verify recovery behavior. The system maintains sub-microsecond alignment between nodes using only commodity hardware and no external time source. To further confirm inter-node timestamp alignment at the signal level, both hardware-based reference signal injection and software-based synchronized signal emulation are employed, providing ground-truth validation alongside scalable and reproducible evaluation. The results show that low-cost embedded hardware can support reliable, long-duration synchronization in fully offline installations.