Due to the great importance for many industrial applications it is crucial from the point of view of theoretical description to reproduce thermal properties of thermoplastic polyimides as accurate as possible in order to establish “chemical structure–physical properties” relationships of new materials. In this paper we employ differential scanning calorimetry, dilatometry, and atomistic molecular dynamics (MD) simulations to explore whether the state-of-the-art computer modeling can serve as a precise tool for probing thermal properties of polyimides with highly polar groups. For this purpose the polyimide R–BAPS based on dianhydride 1,3-bis(3′,4-dicarboxyphenoxy)benzene (dianhydride R) and diamine 4,4′-bis(4′′-aminophenoxy)biphenyl sulphone) (diamine BAPS) was synthesized and extensively studied. Overall, our findings show that the widely used glass-transition temperature Tg evaluated from MD simulations should be employed with great caution for verification of the polyimide computational models against experimental data: in addition to the well-known impact of the cooling rate on the glass-transition temperature, correct definition of Tg requires cooling that starts from very high temperatures (no less than 800 K for considered polyimides) and accurate evaluation of the appropriate cooling rate, otherwise the errors in the measured values of Tg become undefined. In contrast to the glass-transition temperature, the volumetric coefficient of thermal expansion (CTE) does not depend on the cooling rate in the low-temperature domain (T < Tg) so that comparison of computational and experimental values of CTE provides a much safer way for proper validation of the theoretical model when electrostatic interactions are taken into account explicitly. Remarkably, this conclusion is most likely of generic nature: we show that it also holds for the commercial polyimide EXTEM™, another polyimide with a similar chemical structure.
A bilayer nonwoven material for tissue regeneration was prepared from chitosan (CS) and hyaluronic acid (HA) by needleless electrospinning wherein 10–15 wt% (with respect to polysaccharide) polyethylene oxide was added as spinning starter. A fiber morphology study confirmed the material’s uniform defect-free structure. The roughness of the bilayer material was in the range of 1.5–3 μm, which is favorable for cell growth. Electrospinning resulted in the higher orientation of the polymer structure compared with that of corresponding films, and this finding may be related to the orientation of the polymer chains during the spinning process. These structural changes increased the intermolecular interactions. Thus, despite a high swelling degree of 1.4–2.8 g/g, the bilayer matrix maintained its shape due to the large quantity of polyelectrolyte contacts between the chains of oppositely charged polymers. The porosity of the bilayer CS–HA nonwoven material was twice lower, while the Young’s modulus and break stress were twice higher than that of a CS monolayer scaffold. Therefore, during the electrospinning of the second layer, HA may have penetrated into the pores of the CS layer, thereby increasing the polyelectrolyte contacts between the two polymers. The bilayer CS–HA scaffold exhibited good compatibility with mesenchymal stem cells. This characteristic makes the developed material promising for tissue engineering applications.
30 March 2015 in Journal of Polymer Science Part B: Polymer Physics
New composite hydrogels based on cellulose and poly(acrylamide) have been synthesized via radical polymerization of acrylamide in cellulose swollen in a reaction solution. In this study, both a plant form of cellulose and a bacterial form—that cultivated by Acetobacter xylinum bacteria—were used. The behavior of synthesized hydrogels during swelling in water, as well as the behavior of the samples swollen at equilibrium during deformation under uniaxial compression under various test conditions, have been studied. A comparative analysis of the main mechanical characteristics of hydrogels and the appropriate data for various types of articular cartilage, one of which—rabbit knee meniscus—has been tested in this study, has been performed. An average-strength hydrogel is very close to articular cartilage in all mechanical characteristics. The degrees of loading at the highest compression deformations observed during the function of joint cartilage (30–50%) is in the range 4–12 MPa for this hydrogel, and the average values of the compression modulus in the deformation ranges of 10–15 and 25–30% are 8.8 and 23.7 MPa, respectively. The behavior of hydrogels and rabbit meniscus under cyclic compression with the amplitude of 50% has been studied. Hydrogels and meniscus under this test conditions demonstrate clear viscoelastic behavior, evidenced by noticeable hysteresis for the first cycle and a decrease in the value of the maximum load with an increase in the number of cycles. Structural features of hydrogels, which can affect the behavior of the hydrogels under study, have been considered. On the whole, the results demonstrate the possibility of modeling the mechanical behavior of cartilage with the use of hydrogels of this type.