Saeideh Naghdali

Mrs. Saeideh Naghdali

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 January 2016 in Journal of Thermal Analysis and Calorimetry
Verified
Journal Article
Closed access
PDF file
MMM. Malekan
M. Malekan
SNSaeideh Naghdali
Saeideh Naghdali
SAS. Abrishami
S. Abrishami
SMS. H. Mirghaderi
S. H. Mirghaderi

1 November 2021 in Journal of Materials Research and Technology
Verified
Journal Article
Open access
SSS.G. Shabestari
S.G. Shabestari
MAM. Abdi
M. Abdi
SNSaeideh Naghdali
Saeideh Naghdali

17 July 2018 in Thermochimica Acta
Verified
Journal Article
Closed access
SNSaeideh Naghdali
Saeideh Naghdali
HJHassan Jafari
Hassan Jafari
MMMehdi Malekan
Mehdi Malekan

17 June 2025 in Ultramicroscopy
Verified
Journal Article
Open access
SNSaeideh Naghdali
Saeideh Naghdali
MSMaximilian Schiester
Maximilian Schiester
HWHelene Waldl
Helene Waldl
VTVelislava Terziyska
Velislava Terziyska
MHMarcus Hans
Marcus Hans
MTMichael Tkadletz
Michael Tkadletz
This study addresses the challenges in analyzing (Ti,Si)N coatings using atom probe tomography (APT). Overlapping mass-to-charge state ratios in APT mass spectra hinder unambiguous identification of Si and N, thus, isotopic substitution of naturally abundant nitrogen by 15N-enriched nitrogen was applied to disentangle the mass-spectral overlaps. A series of model coatings, namely, Ti-N, Si-N, and Ti-Si-N single layer coatings were utilized to investigate elemental accuracy, while their corresponding multilayer coatings were used to assess lateral resolution and imaging accuracy. The coatings were sputter-deposited using i) naturally abundant nitrogen and ii) 15N-enriched nitrogen, respectively. Subsequently, the coatings were analyzed with a LEAP 5000 XR atom probe. Accuracy in obtained concentrations was cross-validated with elastic recoil detection analysis (ERDA) combined with Rutherford backscattering spectrometry (RBS). The investigation showed that isotopic substitution allows to differentiate the Si and N peaks in the mass spectra and significantly reduces compositional discrepancies between APT and ERDA/RBS results. Despite remaining minor peak overlaps, which can result in inaccuracies in determining the elemental composition, isotopic substitution has proven to be an effective method for peak differentiation and correcting the obtained elemental composition of Ti-Si-N. Moreover, isotopic substitution can predominantly increase the elemental accuracy and imaging accuracy of APT measurements of multilayer coatings.

6 April 2026 in Coatings
Verified
Journal Article
Open access
PDF file
SNSaeideh Naghdali
Saeideh Naghdali
HWHelene Waldl
Helene Waldl
MSMaximilian Schiester
Maximilian Schiester
MPMarkus Pohler
Markus Pohler
CCChristoph Czettl
Christoph Czettl
NSNina Schalk
Nina Schalk
TiN/CrAlN multilayer coatings were synthesized by cathodic arc deposition using 2-fold substrate rotation and alternating targets. The effect of substrate rotation on the layer sequence, elemental fluctuations and interface quality was examined using high-resolution transmission electron microscopy and atom probe tomography. The layers exhibited semi-coherent growth across the interfaces. Minor interface roughness and elemental intermixing limited to below 2 nm at the interface could be observed. Further, the formation of a Ti-enriched sublayer in the Cr1−xAlxN as a result of the 2-fold rotation was identified.