With the evolution of the More Electric Aircraft (MEA) concept, high pulse converters have gained the attention of researchers due to their higher power quality. Among the high pulse converters, 18-pulse autotransformer rectifier unit (ATRU) offers better power quality level with small size, weight and medium complexity. The conventional topologies of autotransformers that require the use of extra elements such as Inter Phase Transformers (IPT) or Zero Sequence Blocking Transformers (ZSBT), adding to the complexity, weight and size of the overall system, are not considered in the analysis. For 18-pulse rectification, only those topologies of autotransformers which have the intrinsic current harmonic cancellation capabilities are presented here for comparison. These topologies offer current harmonic levels within limits specified by IEEE 519 with reduced weight and size as compared to the conventional multi-pulse converters. A comparison of different differential delta/fork configured 18-pulse autotransformer rectifier units is presented so as to come up with the best among available topologies with respect to weight, size and power quality. Experimental prototypes of each topology were designed and their results are displayed along with the simulation results for comparison.
Switching models possess discontinuous and nonlinear behavior, rendering difficulties in simulations in terms of time consumption and computational complexity, leading to mathematical instability and an increase in its vulnerability to errors. This issue can be countered by averaging detailed models over the entire switching period. An attempt is made for deriving improved dynamic average models of three phase (six-pulse) and nine phase (18-pulse) diode rectifiers by approximating load current through first order Taylor series. Small signal AC/DC impedances transfer functions of the average models are obtained using a small signal current injection technique in Simulink, while transfer functions are obtained through identification of the frequency response into the second order system. For the switch models in Simulink and the experimental setup, a small signal line to line shunt current injection technique is used and the obtained frequency response is then identified into second order systems. Sufficient matching among these results proves the validity of the modelling procedure. Exact impedances of the integral parts, in interconnected AC/DC/AC systems, are required for determining the stability through input-output impedances.
A distributed energy system (DES) using controlled power electronics converters delivers power to loads, via conventional, as well as a number of renewable, energy sources. However, stability concerns retard the integration of power electronics converters into an existing DES. Therefore, due to the high penetration of power converters, the overall network analysis of DES is becoming increasingly difficult. Impedance-based DES modeling emerged as an effective technique as it reduces the system into source and load subsystems and offers easier analysis of the dynamic interactions between them. These models can be obtained using either analytical calculations, simulations, or experimental measurements. In this work, firstly, a line-to-line current injection technique is used for the measurement of alternating current (AC) impedances. Since it requires repeated injections, a -domain impedance measurement methodology based upon a set of independent perturbations and measurements is proposed. The perturbation is injected via a sweep signal which is preprocessed by the digital signal processor (DSP) prior to injection. The reference frame is synchronized with the three-phase AC system using a low-bandwidth phase-locked loop (PLL). The close matching of impedance parameters measured in simulation using the proposed approach with those obtained using analytical expressions and the line-to-line current injection technique verifies the effectiveness of the approach. Furthermore, the method was also implemented experimentally, and the close matching of the results with the analytical and simulation results validates the overall modeling and measurement procedure.
27 August 2020 in Journal of Electrical Engineering & Technology
The remarkable progress of power electronic converters (PEC) technology has led to their increased penetration in distributed energy systems (DES). Particularly, the direct current (dc) nanogrid-based DES embody a variety of sources and loads, connected through a central dc bus. Therefore, PECs are required to be employed as an interface. It would facilitate incorporation of the renewable energy sources and battery storage system into dc nanogrids. However, it is more challenging as the integration of multiple modules may cause instabilities in the overall system dynamics. Future dc nanogrids are envisioned to deploy ready-to-use commercial PEC, for which designers have no insight into their dynamic behavior. Furthermore, the high variability of the operating conditions constitute a new paradigm in dc nanogrids. It exacerbates the dynamic analysis using traditional techniques. Therefore, the current work proposes behavioral modeling to perform system level analysis of a dc nanogrid-based DES. It relies only on the data acquired via measurements performed at the input–output terminals only. To verify the accuracy of the model, large signal disturbances are applied. The matching of results for the switch model and its behavioral model verifies the effectiveness of the proposed model.