Shinji Ninomiya

Dr. Shinji Ninomiya

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 June 2010 in The Journal of ExtraCorporeal Technology
Verified
Journal Article
Open access
PDF file
ATAsako Tokumine
Asako Tokumine
SNShinji Ninomiya
Shinji Ninomiya
MTMegumi Tokaji
Megumi Tokaji
TKTatsuya Kurosaki
Tatsuya Kurosaki
YTYasuko Tomizawa
Yasuko Tomizawa
Although serious accidents during extracorporeal circulation are infrequent, potential adverse events with both equipment and operation do still occur and require immediate and well-coordinated responses. Hence, perfusionists need to be well trained in both standard and emergency procedures, and this would be aided by the establishment of an official education and training curriculum. In particular, the establishment of a simulator-based educational program and corresponding evaluation methods will spur development of increasingly medical simulators. Extra-Corporeal Circulation SIMulator (ECCSIM-Lite) was used during repeated sessions of undergraduate students (n= 12) using a simple training scenario. Trainees aimed to maintain reservoir volume around a constant mean, and increase or decrease the arterial flow avoiding rapid variations, and their performance was monitored. Ability to prevent backflow was also recorded as a measure of accomplishment. Skills in performances were evaluated by using a scoring system based on task accomplishment. Accomplishment score was improved in all participants after 1 week of training. Accomplishment scores reflecting ability to maintain flow improved to an average of 78%; in the third and final practice session backflow was prevented in 100% of cases. The average reservoir level maintenance score in the flow-up phase was 75%, in the flow-maintenance phase was 92%, and in the flow-down phase was 58%. During skill training, in which trainees learn methods of avoiding adverse events, the use of simulators combined with tractable skills scores can ease the transition from training session to clinical practice. Use of these training scenarios within a perfusion education system also has the advantage of providing an index of trainees’ current proficiency and improvement by providing tractable skill scores. In conclusion, the use of ECCSIM-Lite simulations, together with evaluation of task accomplishment over repeated training sessions, is an effective method of basic skill training for perfusionists.

24 April 2020 in Journal of Medical and Biological Engineering
Verified
Journal Article
Open access
PDF file
NCNoriyo Colley
Noriyo Colley
Hiroki ManiHiroki Mani
Hiroki Mani
SNShinji Ninomiya
Shinji Ninomiya
SKShunsuke Komizunai
Shunsuke Komizunai
EMEri Murata
Eri Murata
Tadayoshi AsakaTadayoshi Asaka
Tadayoshi Asaka
Purpose The aim of this study was to determine the effective biomechanical technique for suctioning phlegm. Methods A novel tracheal suctioning simulator combined with a motion capture system was used to calculate the amount of simulated phlegm suctioned and the biomechanical parameters of the associated suctioning manoeuvre. A laboratory study, including 12 nurses with > 3 years of suctioning experience and 12 nursing students without any clinical suctioning experience, was conducted. The amount of phlegm suctioned, the maximum length of catheter insertion, and the biomechanical parameters of hand movement were calculated. Results The mean amount of phlegm suctioned per second was significantly larger in the experienced group than in the non-experienced group. The amount of phlegm suctioned correlated positively with the length of the vertical path of motion of the wrist and forearm, and with the angular velocity of thumb rotation in both the groups. Conclusion Greater vertical motion of the wrist and thumb rotation improved the effectiveness of phlegm suctioning and prevented the need for deep suctioning, which is unsafe.

17 February 2023 in Journal of International Nursing Research
Verified
Journal Article
Open access
PDF file
NCNoriyo Colley
Noriyo Colley
SKShunsuke Komizunai
Shunsuke Komizunai
SKSatoshi Kanai
Satoshi Kanai
AKAtsushi Konno
Atsushi Konno
SISozo Inoue
Sozo Inoue
SNShinji Ninomiya
Shinji Ninomiya
Objective: We developed a suctioning catheter control sensing device given the increasing demand for skilled home-based healthcare techniques, such as tracheal suctioning. This study evaluated the proficiency of the entire tracheal suctioning process between expert and novice groups via the suctioning catheter control sensing device and a motion capture system. Our hypothesis is that motion capture can measure the proficiency of tracheal suctioning despite the biological reactions of the simulator and the characteristics of participants. Methods: Nine expert nurses, each with more than three years of clinical experience in tracheal suctioning, and 13 nursing students from an urban university nursing department participated. The performance time, pelvic forward bending angle, travel distance, posing time, posing frequency of bilateral dorsum manus, and suctioning catheter control between the two groups with/without simulated biological reactions were analyzed. Results: The two-way analysis of variance demonstrated that the biological reactions (or lack thereof) and the proficiency level did not interact. The main effect of performance time, posing time, and posing frequency was statistically significant; experts performed tracheal suctioning more expeditiously and skillfully. The sensing device could detect hesitance or rough catheter control. Conclusions: Our results indicated that performance time, posing time, and posing frequency could serve as proficiency criteria with/out biological reactions. Additional studies are required to establish a quantitative education evaluation method to determine clinically reliable proficiency levels of tracheal suctioning.

27 February 2026 in Sensors
Verified
Journal Article
Open access
PDF file
NCNoriyo Colley
Noriyo Colley
SKShunsuke Komizunai
Shunsuke Komizunai
ASAtsuko Sato
Atsuko Sato
TITakanori Ishikawa
Takanori Ishikawa
MKMayumi Kochiyama
Mayumi Kochiyama
SNShinji Ninomiya
Shinji Ninomiya
Background: Existing XR simulators for enteral feeding rely mainly on self-reported learning outcomes and procedural checklists. As a result, they offer limited opportunities to capture objective behavioral data or to present dynamic patient reactions. This two-stage pilot study evaluated an XR-based gastrostomy tube-feeding simulator (ESTE-TF) that integrates sensor-derived performance metrics and two biological-reaction presentation modalities (projection mapping and tablet display). Methods: In Experiment 1, nursing students completed pre- and post-experience questionnaires assessing perceived learning across seven domains, alongside sensor-based measurements of feeding-start timing, dosing-rate characteristics, and total procedure time. Experiment 2 employed a tablet-based version with four learning items assessed for students and post-experience evaluations collected from registered nurses. Participants also compared the two XR presentation methods. Results: Students demonstrated perceived learning gains of small-to-large magnitude across both experiments (Experiment 1: d = 0.455–0.974; Experiment 2: d = 0.014–0.886), with wide 95% confidence intervals reflecting the exploratory nature of this pilot work. Sensor-derived data showed greater dosing-rate variability and longer procedure times among students than nurses. Participants reported that projection mapping offered a more embodied experience, whereas tablet displays provided clearer visibility. Conclusions: These findings indicate the feasibility and preliminary educational potential of integrating sensing technologies with XR-based biological-reaction presentation for gastrostomy-feeding training. Given the small samples and non-validated measures, results should be interpreted as exploratory. Future research will refine sensor accuracy, establish standardized performance metrics, and evaluate learning outcomes using validated instruments and controlled study designs.

2 January 2025 in Prehospital Emergency Care
Verified
Journal Article
Closed access
YTYutaka Takei
Yutaka Takei
GTGen Toyama
Gen Toyama
TATetsuhiro Adachi
Tetsuhiro Adachi
TNTaiki Nishi
Taiki Nishi
YYYasuharu Yasuda
Yasuharu Yasuda
AOAkane Ozaki
Akane Ozaki
To compare the effects of powered and manual stretchers on participants' perceived comfort and measured acceleration during lifting and loading operations. This non-randomized, laboratory-based crossover study involved forty-one participants (thirty-one firefighters and ten third-year paramedic students) who served as simulated patients experiencing lifting, lowering, loading, and unloading maneuvers using manual and powered stretchers. Four stretcher types were evaluated: one powered stretcher (Power-PRO™ XT) and three manual stretchers (Matsunaga GT, Exchange 4070, Scad Mate), with each group using the manual stretcher they routinely operated. Linear acceleration data were collected using a nine-axis inertial measurement unit placed at the participants' anterior waist. Root mean square (RMS) and peak accelerations along the X-, Y-, and Z-axes were calculated. Participants completed a twenty-three-item comfort questionnaire based on the Semantic Differential method. Due to non-normal data distribution, nonparametric statistical tests were employed for analysis. The lifting/lowering and loading/unloading movements showed that the powered stretcher significantly reduced the RMS values, maximum accelerations, and minimum accelerations in the vertical axis (Z-axis) compared to manual stretchers. Specifically, the powered stretcher demonstrated lower RMS acceleration (0.29 m/s² vs. 0.73 m/s², p < 0.001), maximum acceleration (1.60 m/s² vs. 2.90 m/s², p < 0.001), and minimum acceleration (-1.48 m/s² vs. -3.30 m/s², p < 0.001) in the vertical direction compared to other manual stretchers. Similar results were observed in the comparison of participant loading/unloading movements. However, no significant differences were observed between the powered and Exchange stretchers in X-axis minimum acceleration, Y-axis maximum and minimum accelerations, or Z-axis maximum acceleration. Similarly, Y-axis minimum accelerations did not significantly differ between the powered stretcher and Matsunaga GT or Scad Mate stretchers. After loading and unloading movements, the questionnaire results showed that the powered stretcher was rated significantly higher on comfort-related items including "comfortable," "secure," "like," "smooth," and "relaxing." In a controlled, laboratory-based setting, simulated use of manual and powered stretchers showed that powered stretchers significantly minimize patient discomfort and vibrations. This study underscores the potential for enhancing patient safety and quality of care. In conclusion, the powered stretcher is a promising tool for improving the quality and safety of patient transportation in prehospital settings.