Noriyo Colley

Dr. Noriyo Colley

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 April 2020 in Journal of Medical and Biological Engineering
Verified
Journal Article
Open access
PDF file
NCNoriyo Colley
Noriyo Colley
Hiroki ManiHiroki Mani
Hiroki Mani
SNShinji Ninomiya
Shinji Ninomiya
SKShunsuke Komizunai
Shunsuke Komizunai
EMEri Murata
Eri Murata
Tadayoshi AsakaTadayoshi Asaka
Tadayoshi Asaka
Purpose The aim of this study was to determine the effective biomechanical technique for suctioning phlegm. Methods A novel tracheal suctioning simulator combined with a motion capture system was used to calculate the amount of simulated phlegm suctioned and the biomechanical parameters of the associated suctioning manoeuvre. A laboratory study, including 12 nurses with > 3 years of suctioning experience and 12 nursing students without any clinical suctioning experience, was conducted. The amount of phlegm suctioned, the maximum length of catheter insertion, and the biomechanical parameters of hand movement were calculated. Results The mean amount of phlegm suctioned per second was significantly larger in the experienced group than in the non-experienced group. The amount of phlegm suctioned correlated positively with the length of the vertical path of motion of the wrist and forearm, and with the angular velocity of thumb rotation in both the groups. Conclusion Greater vertical motion of the wrist and thumb rotation improved the effectiveness of phlegm suctioning and prevented the need for deep suctioning, which is unsafe.

29 March 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
TYTakaaki Yoshimura
Takaaki Yoshimura
NCNoriyo Colley
Noriyo Colley
SKShunsuke Komizunai
Shunsuke Komizunai
SNShinji Ninomiya
Shinji Ninomiya
SKSatoshi Kanai
Satoshi Kanai
SSShinichi Shimizu
Shinichi Shimizu
Tracheal suctioning is an important procedure to maintain airway patency by removing secretions. Today, suctioning operators include not only medical staff, but also family caregivers. The use of a simulation system has been noted to be the most effective way to learn the tracheal suctioning technique for operators. While the size of the trachea varies across different age groups, the artificial trachea model in the simulation system has only one fixed model. Thus, this study aimed to construct multiple removable trachea models according to different age groups. We enrolled 20 patients who had previously received proton beam therapy in our institution and acquired the treatment planning computed tomography (CT) image data. To construct the artificial trachea model for three age groups (children, adolescents and young adults, and adults), we analyzed the three-dimensional coordinates of the entire trachea, tracheal carina, and the end of the main bronchus. We also analyzed the diameter of the trachea and main bronchus. Finally, we evaluated the accuracy of the model by analyzing the difference between the constructed model and actual measurements. The trachea model was 8 cm long for children and 12 cm for adolescents and young adults, and for adults. The angle between the trachea and bed was about 20 degrees, regardless of age. The mean model accuracy was less than 0.4 cm. We constructed detachable artificial trachea models for three age groups for implementation in the endotracheal suctioning training environment simulator (ESTE-SIM) based on the treatment planning CT image. Our constructed artificial trachea models will be able to provide a simulation environment for various age groups in the ESTE-SIM.

1 January 2020 in SAGE Open Nursing
Verified
Journal Article
Open access
PDF file
NCNoriyo Colley
Noriyo Colley
SKShunsuke Komizunai
Shunsuke Komizunai
AKAtsushi Konno
Atsushi Konno
SKSatoshi Kanai
Satoshi Kanai
SNShinji Ninomiya
Shinji Ninomiya
Background: To provide safe tracheal suctioning, the American Association of Respiratory Care guideline discusses the length of suctioning catheter, but the most effective tracheal suctioning catheter technique is still unknown. Objective: The aim of this study is to compare the amount of simulated secretion produced by five different handlings of a catheter at two different viscosities and in two different models to discover the most effective suctioning maneuver in the various mucus conditions. Design: In vitro experimental design. Methods: The amount of secretion aspirated by our researcher's manipulation of a suctioning catheter was measured. The tip of the catheter was recorded using a high-speed video camera to visualize the secretion motion. Results: The most effective suctioning technique differed depending on the viscosity of the secretion. There were no significant differences between five suctioning methods applied to high-viscosity phlegm in a tracheal membrane model, but the flexion technique was the most efficient for low-viscosity secretion. Conclusions: Our results imply that the flexion technique was reasonably safe and the most effective of these five methods for low-viscosity secretion.

1 January 2026 in Teaching and Learning in Nursing
Verified
Journal Article
Open access
SRSilvia Ronchi
Silvia Ronchi
Rosario CarusoRosario Caruso
Rosario Caruso
DFDiletta Fabrizi
Diletta Fabrizi
MLMichela Luciani
Michela Luciani
CACeleste M. Alfes
Celeste M. Alfes
DADavide Ausili
Davide Ausili

21 August 2024
Verified
Book Chapter
Open access
PDF file
NCNoriyo Colley
Noriyo Colley
XR is a term within the spectrum of virtual reality (VR), mixed reality (MR), and augmented reality (AR). In 2015, Endotracheal Suctioning Training Environment SIMulator (ESTE-SIM) project team was established (PI: Noriyo Colley), which consisted of a wide range of disciplines including nursing science, information science, and healthcare engineering to promote the development of a pedagogical environment for quality care through simulation education. Mutual recognition was found that a digital transformation plays an important role to mitigate the risks of global shortages of nurses and healthcare faculty due to pandemic, ultra-aging society, and technology dependent children such as children with home mechanical ventilators. Nursing XR simulators are being developed for Diversity, Equity & Inclusion, which is a new purpose of future technology development.

17 February 2023 in Journal of International Nursing Research
Verified
Journal Article
Open access
PDF file
NCNoriyo Colley
Noriyo Colley
SKShunsuke Komizunai
Shunsuke Komizunai
SKSatoshi Kanai
Satoshi Kanai
AKAtsushi Konno
Atsushi Konno
SISozo Inoue
Sozo Inoue
SNShinji Ninomiya
Shinji Ninomiya
Objective: We developed a suctioning catheter control sensing device given the increasing demand for skilled home-based healthcare techniques, such as tracheal suctioning. This study evaluated the proficiency of the entire tracheal suctioning process between expert and novice groups via the suctioning catheter control sensing device and a motion capture system. Our hypothesis is that motion capture can measure the proficiency of tracheal suctioning despite the biological reactions of the simulator and the characteristics of participants. Methods: Nine expert nurses, each with more than three years of clinical experience in tracheal suctioning, and 13 nursing students from an urban university nursing department participated. The performance time, pelvic forward bending angle, travel distance, posing time, posing frequency of bilateral dorsum manus, and suctioning catheter control between the two groups with/without simulated biological reactions were analyzed. Results: The two-way analysis of variance demonstrated that the biological reactions (or lack thereof) and the proficiency level did not interact. The main effect of performance time, posing time, and posing frequency was statistically significant; experts performed tracheal suctioning more expeditiously and skillfully. The sensing device could detect hesitance or rough catheter control. Conclusions: Our results indicated that performance time, posing time, and posing frequency could serve as proficiency criteria with/out biological reactions. Additional studies are required to establish a quantitative education evaluation method to determine clinically reliable proficiency levels of tracheal suctioning.