Robert J. Paneque-Yunta

Mr. Robert J. Paneque-Yunta

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 July 2025 in Physics in Medicine & Biology
Verified
Journal Article
Open access
RPRobert J. Paneque-Yunta
Robert J. Paneque-Yunta
NENerea Encina-Baranda
Nerea Encina-Baranda
LCLukas M Carter
Lukas M Carter
PGPablo Galve
Pablo Galve
PIPaula Ibáñez
Paula Ibáñez
JHJOAQUIN L. HERRAIZ
JOAQUIN L. HERRAIZ
Introduction: The positron range (PR) effect is a significant factor limiting spatial resolution in positron emission tomography (PET), particularly for high-resolution systems and non-standard isotopes. Objective: This study introduces a novel analytical model to accurately and rapidly describe positron range distributions (PRd) for various PET radioisotopes. Approach: The proposed model explicitly incorporates the Coulomb repulsion effect, the multi-branch nature of certain β+ emitters, and the scaling of PR with electronic density. To minimise bias, we used a histogram-free statistical method to derive the cumulative PRd from Monte Carlo (MC) simulated annihilation datasets, avoiding arbitrary histogram binning. A comparative analysis of PR estimates was conducted across three major MC radiation transport algorithm packages: PENELOPE (via PenEasy/PeneloPET), GEANT4 (via GATE), and EGS5 (via PHITS), revealing notable discrepancies between codes, versions, and input configurations, especially at short distances from the source. Main results: The new analytical model demonstrated an excellent reproduction of the simulated data for isotopes including C-11, N-13, O-15, F-18, Cu-64, Ga-68, Rb-82, and I-124, achieving in general coefficients of determination (R2) greater than 0.995 and mean absolute percentage errors (MAPE) < 20%. Compared to previous methods, our model provides a more accurate description of PRd at short and long distances and offers improved R2 values. Significance: This work provides a robust framework for generating accurate annihilation point spread function (aPSF) kernels, facilitating improved PR correction in quantitative Nuclear Medical imaging and supporting research with diverse radioisotopes.

4 July 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RPRobert J. Paneque-Yunta
Robert J. Paneque-Yunta
NENerea Encina-Baranda
Nerea Encina-Baranda
JHJOAQUIN L. HERRAIZ
JOAQUIN L. HERRAIZ
KAKhaled M A Abushab
Khaled M A Abushab
JUJose MANUEL Udias
Jose MANUEL Udias
PIPaula Ibáñez
Paula Ibáñez
Positron range (PR) degrades spatial resolution in positron emission tomography (PET), with its effect being radionuclide- and medium-dependent. Current accurate PR simulators are computationally intensive and cannot be used in clinical time frames. This work presents the Hybrid Monte Carlo (HMC) PR simulator, a GPU-accelerated condensed-history code in CUDA Fortran for 3D annihilation imaging in heterogeneous voxelised geometries derived from CT images and μ-maps. Pre-computed look-up interaction tables (LUTs) covering 24 reference-tissue materials and support for arbitrary β+ emitters up to 3.55 MeV end-point energies (68Ga, 82Rb, 124I, etc.) allow both GPU and CPU implementations. Maximum speeds reach 4.77·105 (Intel i9-14900KF) and 3.32·108 (NVIDIA RTX 5080) histories/s, surpassing prior CPU-only PenEasy 2024 by up to 4 orders of magnitude. A fixed step of 0.5 mm was chosen for LUT generation with a uniform ±10% variation each HMC step that allowed reducing aliasing effects. These values are consistent with our previous cross-code benchmark for the isotopes studied. Close agreement with PenEasy 2024 is demonstrated: point-source FWHM and FWTM residuals using 18F, 68Ga, 124I and 82Rb are below 0.3 mm at 107 histories, and voxelwise R2=0.995, SSIM=0.995 and PSNR ≈36.4 dB are achieved simulating 82Rb uptake from a human-scale [18F]FDG myocardium acquisition, while decreasing the simulation time from almost 9 h to roughly 1 s using HMC GPU. The resulting annihilation maps enable PET resolution modelling and patient-specific PR correction within clinically practical time frames.