Khaled M A Abushab

Dr. Khaled M A Abushab

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2019 in Physica B: Condensed Matter
Verified
Journal Article
Closed access
YAYasser Alajerami
Yasser Alajerami
MMMohammad Hasan Abu Mhareb
Mohammad Hasan Abu Mhareb
KAKhaled M A Abushab
Khaled M A Abushab
KRKhaled Ramadan
Khaled Ramadan

1 September 2018 in Results in Physics
Verified
Journal Article
Open access
MMMohammad Hasan Abu Mhareb
Mohammad Hasan Abu Mhareb
MMMaghrabi Maghrabi
Maghrabi Maghrabi
YAYasser Alajerami
Yasser Alajerami
SHSuhairul Hashim
Suhairul Hashim
SGS.K. Ghoshal
S.K. Ghoshal
KAKhaled M A Abushab
Khaled M A Abushab

29 July 2025 in Physics in Medicine & Biology
Verified
Journal Article
Open access
RPRobert J. Paneque-Yunta
Robert J. Paneque-Yunta
NENerea Encina-Baranda
Nerea Encina-Baranda
LCLukas M Carter
Lukas M Carter
PGPablo Galve
Pablo Galve
PIPaula Ibáñez
Paula Ibáñez
JHJOAQUIN L. HERRAIZ
JOAQUIN L. HERRAIZ
Introduction: The positron range (PR) effect is a significant factor limiting spatial resolution in positron emission tomography (PET), particularly for high-resolution systems and non-standard isotopes. Objective: This study introduces a novel analytical model to accurately and rapidly describe positron range distributions (PRd) for various PET radioisotopes. Approach: The proposed model explicitly incorporates the Coulomb repulsion effect, the multi-branch nature of certain β+ emitters, and the scaling of PR with electronic density. To minimise bias, we used a histogram-free statistical method to derive the cumulative PRd from Monte Carlo (MC) simulated annihilation datasets, avoiding arbitrary histogram binning. A comparative analysis of PR estimates was conducted across three major MC radiation transport algorithm packages: PENELOPE (via PenEasy/PeneloPET), GEANT4 (via GATE), and EGS5 (via PHITS), revealing notable discrepancies between codes, versions, and input configurations, especially at short distances from the source. Main results: The new analytical model demonstrated an excellent reproduction of the simulated data for isotopes including C-11, N-13, O-15, F-18, Cu-64, Ga-68, Rb-82, and I-124, achieving in general coefficients of determination (R2) greater than 0.995 and mean absolute percentage errors (MAPE) < 20%. Compared to previous methods, our model provides a more accurate description of PRd at short and long distances and offers improved R2 values. Significance: This work provides a robust framework for generating accurate annihilation point spread function (aPSF) kernels, facilitating improved PR correction in quantitative Nuclear Medical imaging and supporting research with diverse radioisotopes.

4 July 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RPRobert J. Paneque-Yunta
Robert J. Paneque-Yunta
NENerea Encina-Baranda
Nerea Encina-Baranda
JHJOAQUIN L. HERRAIZ
JOAQUIN L. HERRAIZ
KAKhaled M A Abushab
Khaled M A Abushab
JUJose MANUEL Udias
Jose MANUEL Udias
PIPaula Ibáñez
Paula Ibáñez
Positron range (PR) degrades spatial resolution in positron emission tomography (PET), with its effect being radionuclide- and medium-dependent. Current accurate PR simulators are computationally intensive and cannot be used in clinical time frames. This work presents the Hybrid Monte Carlo (HMC) PR simulator, a GPU-accelerated condensed-history code in CUDA Fortran for 3D annihilation imaging in heterogeneous voxelised geometries derived from CT images and μ-maps. Pre-computed look-up interaction tables (LUTs) covering 24 reference-tissue materials and support for arbitrary β+ emitters up to 3.55 MeV end-point energies (68Ga, 82Rb, 124I, etc.) allow both GPU and CPU implementations. Maximum speeds reach 4.77·105 (Intel i9-14900KF) and 3.32·108 (NVIDIA RTX 5080) histories/s, surpassing prior CPU-only PenEasy 2024 by up to 4 orders of magnitude. A fixed step of 0.5 mm was chosen for LUT generation with a uniform ±10% variation each HMC step that allowed reducing aliasing effects. These values are consistent with our previous cross-code benchmark for the isotopes studied. Close agreement with PenEasy 2024 is demonstrated: point-source FWHM and FWTM residuals using 18F, 68Ga, 124I and 82Rb are below 0.3 mm at 107 histories, and voxelwise R2=0.995, SSIM=0.995 and PSNR ≈36.4 dB are achieved simulating 82Rb uptake from a human-scale [18F]FDG myocardium acquisition, while decreasing the simulation time from almost 9 h to roughly 1 s using HMC GPU. The resulting annihilation maps enable PET resolution modelling and patient-specific PR correction within clinically practical time frames.

7 March 2021 in Electronic Journal of General Medicine
Verified
Journal Article
Open access
PDF file
YAYasser Alajerami
Yasser Alajerami
HMHusam H Mansour
Husam H Mansour
KAKhaled M A Abushab
Khaled M A Abushab
Consequent to the extended use of intravenous iodinated contrast media, increased adverse effects have been recognized, with Contrast-Induced Nephropathy (CIN) constituting one of the most serious of these adverse effects. The purpose of the current study was to investigate a prophylaxis strategy for reducing the effect of intravenous contrast on the development of CIN. Data were collected from 120 patients who received intravenous iodinated contrast agents during CT procedures. CIN was defined as a relative increase of more than 25% or an absolute increase of ≥ 0.5 mg/dL (44 µmol/L) in serum creatinine levels within 48-72 hours post-CT. Our prophylaxis strategy involved intravenous administration of 500 ml normal saline within one hour before the CT procedure and 3 liters of oral hydration within 12 hours post-CT. Additionally, the volume of administered low osmolality contrast media was based on the weight of the patient. A paired t-test revealed no statistically significant differences in creatinine (t = 0.07, P = 0.942) or urea (t = 0.52, P = 0.608) pre-CT vs. post intravenous iodinated contrast media-enhanced CT. Use of low osmolality contrast media and good hydration pre and post intravenous iodinated contrast administration are effective approaches to the prevention of CIN.