Chandra Teja Uppuluri

Dr. Chandra Teja Uppuluri


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 March 2017 in AAPS PharmSciTech
Verified
Journal Article
Open access
PDF file
PMPangkhi Medhi
Pangkhi Medhi
OOOlolade Olatunji
Ololade Olatunji
ANAtul Nayak
Atul Nayak
CUChandra Teja Uppuluri
Chandra Teja Uppuluri
RORichard T. Olsson
Richard T. Olsson
Diganta Bhusan DasDiganta Bhusan Das
Diganta Bhusan Das
Microneedle (MN) technology has emerged as an effective drug delivery system, and it has tremendous potential as a patient friendly substitute for conventional methods for transdermal drug delivery (TDD). In this paper, we report on the preparation of lidocaine-loaded biodegradable microneedles, which are manufactured from fish scale-derived collagen. Lidocaine, a common tissue numbing anaesthetic, is loaded in these microneedles with an aim of delivering the drug with controlled skin permeation. Evaluation of lidocaine permeation in porcine skin has been successfully performed using Franz diffusion cell (FDC) which has shown that the drug permeation rate increases from 2.5 to 7.5% w/w after 36 h and pseudo steady state profile is observed from 5.0 to 10.0% w/w lidocaine-loaded microneedle. Swelling experiments have suggested that the microneedles have negligible swellability which implies that the patch would stick to the tissue when inserted. The experiments on MN dissolution have depicted that the lidocaine loaded in the patch is lower than the theoretical loading, which is expected as there can be losses of the drug during initial process manufacture.

1 December 2018 in Journal of Chromatography B
Verified
Journal Article
Closed access
ADAvantika V. Dalvi
Avantika V. Dalvi
CUChandra Teja Uppuluri
Chandra Teja Uppuluri
EBEkta Prasanthi Bommireddy
Ekta Prasanthi Bommireddy
PRPunna Rao Ravi
Punna Rao Ravi

28 December 2015 in Current Drug Delivery
Verified
Journal Article
Closed access
BNBuchi Nalluri
Buchi Nalluri
SASai V. Anusha
Sai V. Anusha
SBSri Bramhini
Sri Bramhini
JAJ. Amulya
J. Amulya
ASAshraf Sultana
Ashraf Sultana
DDDiganta Das
Diganta Das
Different dimensions of commercially available microneedle devices, namely, Admin- Patch® microneedle arrays (MN) (0.6, 0.9, 1.2 and 1.5 mm lengths) and Dermaroller® microneedle rollers (DR) (0.5 and 1mm lengths) were evaluated for their relative efficiency in enhancement of transdermal permeation of Sumatriptan (SMT). Solubility assessment of SMT was carried out using propylene glycol (PG), polyethylene glycol (PEG) in combination with saline (S) at different ratios and the order of solubility was found to be 70:30 > 80:20 > 90:10 %v/v in both PG:S and PEG:S. In vitro skin permeation studies were performed using PG:S (70:30 %v/v) as donor vehicle. A significant increase in cumulative amount of SMT permeated, steady state flux, permeability coefficient and diffusion coefficient values were observed after microneedle treatment, and the values were in the order of 1.5mm MN >1.2mm MN >0.9mm MN >1mm DR >0.6mm MN >0.5mm DR > passive permeation. Lag times were significantly shorter after longer microneedle application (0.24h for 1.5mm MN). Arrays were found to be superior to rollers with similar microneedle lengths in enhancing SMT permeation and may be attributed to higher density of microneedles and force of application onto skin. The in vitro flux values revealed that 2.5cm2 area patch is sufficient for effective therapy after treatment of skin with 1.5mm MN. It may be inferred that microneedle application significantly enhances the transdermal penetration of SMT and that it may be feasible to deliver clinically relevant therapeutic levels of SMT using microneedle assisted transdermal delivery systems.

11 January 2017 in AAPS PharmSciTech
Verified
Journal Article
Open access
PDF file
CUChandra Teja Uppuluri
Chandra Teja Uppuluri
ASAshraf Sultana Shaik
Ashraf Sultana Shaik
THTao Han
Tao Han
ANAtul Nayak
Atul Nayak
KNKarthik J. Nair
Karthik J. Nair
Diganta Bhusan DasDiganta Bhusan Das
Diganta Bhusan Das
The present study was aimed to investigate the effect of salient microneedle (MN) geometry parameters like length, density, shape and type on transdermal permeation of rizatriptan (RIZ). Studies were carried out using two types of MN devices viz. AdminPatch® arrays (ADM) (0.6, 0.9, 1.2 and 1.5 mm lengths) and laboratory-fabricated polymeric MNs (PMs) of 0.6 mm length. In the case of the PMs, arrays were applied three times at different places within a 1.77-cm2 skin area (PM-3) to maintain the MN density closer to 0.6 mm ADM. Histological studies revealed that PM, owing to their geometry/design, formed wider and deeper microconduits when compared to ADM of similar length. Approximately 4.9- and 4.2-fold increases in the RIZ steady-state flux values were observed with 1.5 mm ADM and PM-3 applications when compared to the passive studies. A good correlation between different dimensionless parameters like the amount of RIZ permeated (Ct/Cs), thickness (h/L) and surface area (Sa/L2) of the skin was observed with scaling analyses. Numerical simulations provided further information regarding the distribution of RIZ in MN-treated skin after application of different MNs. Overall, the study suggests that MN application enhances the RIZ transdermal permeation and the geometrical parameters of MNs play an important role in the degree enhancement.

20 April 2017 in Drug Development and Industrial Pharmacy
Verified
Journal Article
Open access
CUChandra Teja Uppuluri
Chandra Teja Uppuluri
JDJyothirmayee Devineni
Jyothirmayee Devineni
THTao Han
Tao Han
ANAtul Nayak
Atul Nayak
KNKartik J. Nair
Kartik J. Nair
BNBuchi N. Nalluri
Buchi N. Nalluri
Objective: The present study was aimed to investigate the effect of salient microneedle (MN) geometry parameters like length, density, shape and type on transdermal permeation enhancement of Zolmitriptan (ZMT). Methods: Two types of MN devices viz. AdminPatch® arrays (ADM) (0.6, 0.9, 1.2 and 1.5 mm lengths) and laboratory fabricated polymeric MNs (PM) of 0.6 mm length were employed. In the case of PMs, arrays were applied thrice at different places within a 1.77 cm2 skin area (PM-3) to maintain the MN density closer to 0.6 mm ADM. Scaling analyses was done using dimensionless parameters like concentration of ZMT (Ct/Cs), thickness (h/L) and surface area of the skin (Sa/L2). Results: Micro-injection molding technique was employed to fabricate PM. Histological studies revealed that the PM, owing to their geometry/design, formed wider and deeper microconduits when compared to ADM of similar length. Approximately 3.17- and 3.65-fold increase in ZMT flux values were observed with 1.5 mm ADM and PM-3 applications when compared to the passive studies. Good correlations were observed between different dimensionless parameters with scaling analyses. Numerical simulations, using MATLAB and COMSOL software, based on experimental data and histological images provided information regarding the ZMT skin distribution after MN application. Discussion: Both from experimental studies and simulations, it was inferred that PM were more effective in enhancing the transdermal delivery of ZMT when compared to ADM. Conclusions: The study suggests that MN application enhances the ZMT transdermal permeation and the geometrical parameters of MNs play an important role in the degree of such enhancement.

3 February 2017 in Drug Delivery and Translational Research
Verified
Journal Article
Open access
PDF file
BNBuchi N. Nalluri
Buchi N. Nalluri
CUChandra Teja Uppuluri
Chandra Teja Uppuluri
JDJyothirmayee Devineni
Jyothirmayee Devineni
ANAtul Nayak
Atul Nayak
KNKarthik J. Nair
Karthik J. Nair
DDDiganta B. Das
Diganta B. Das
The present study aimed to investigate the effect of microneedle (MN) geometry parameters like length, density, shape and type on transdermal permeation enhancement of amlodipine (AMLO). Two types of MN devices viz. AdminPatch® arrays (ADM) (0.6, 1.2 and 1.5 mm lengths) and laboratory-fabricated polymeric MNs (PM) of 0.6 mm length were employed. In the case of PMs, arrays were applied thrice at different places within a 1.77-cm2 skin area (PM-3) to maintain the MN density closer to 0.6 mm ADM. Scaling analyses were done using dimensionless parameters like concentration of AMLO (Ct/Cs), thickness (h/L) and surface area of the skin (Sa/L2). Microinjection moulding technique was employed to fabricate PM. Histological studies revealed that the PM, owing to their geometry/design, formed wider and deeper microconduits when compared to ADM of similar length. Approximately 6.84- and 6.11-fold increase in the cumulative amount (48 h) of AMLO permeated was observed with 1.5 mm ADM and PM-3 treatments respectively, when compared to passive permeation amounts. Good correlations (R2 > 0.89) were observed between different dimensionless parameters with scaling analyses. The enhancement in AMLO permeation was found to be in the order of 1.5 mm ADM ≥ PM-3 > 1.2 mm ADM > 0.6 mm ADM ≥PM-1 > passive. The study suggests that MN application enhances the AMLO transdermal permeation and the geometrical parameters of MNs play an important role in the degree of such enhancement.