Şükrü Taner AZGIN

Dr. Şükrü Taner AZGIN


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 July 2016 in Waste Management & Research: The Journal for a Sustainable Circular Economy
Verified
Journal Article
Closed access
FDFiliz Dadaser-Celik
Filiz Dadaser-Celik
ŞAŞükrü Taner AZGIN
Şükrü Taner AZGIN
YYYalcin Sevki Yildiz
Yalcin Sevki Yildiz
Biogas production from food waste has been used as an efficient waste treatment option for years. The methane yields from decomposition of waste are, however, highly variable under different operating conditions. In this study, a statistical experimental design method (Taguchi OA9) was implemented to investigate the effects of simultaneous variations of three parameters on methane production. The parameters investigated were solid content (SC), carbon/nitrogen ratio (C/N) and food/inoculum ratio (F/I). Two sets of experiments were conducted with nine anaerobic reactors operating under different conditions. Optimum conditions were determined using statistical analysis, such as analysis of variance (ANOVA). A confirmation experiment was carried out at optimum conditions to investigate the validity of the results. Statistical analysis showed that SC was the most important parameter for methane production with a 45% contribution, followed by F/I ratio with a 35% contribution. The optimum methane yield of 151 l kg−1 volatile solids (VS) was achieved after 24 days of digestion when SC was 4%, C/N was 28 and F/I were 0.3. The confirmation experiment provided a methane yield of 167 l kg−1 VS after 24 days. The analysis showed biogas production from food waste may be increased by optimization of operating conditions.


15 September 2020 in Water Resources
Verified
Journal Article
Closed access
PDF file
ŞAŞükrü Taner AZGIN
Şükrü Taner AZGIN
FDFiliz Dadaser-Celik
Filiz Dadaser-Celik
In this study, hydrologic regimes of the Palas basin have been investigated with land use/land cover (LULC) change. To investigate the relationship between precipitation and surface runoff, a SWAT (Soil and Water Assessment Tool) model was developed and runoff response was analysed under different LULC conditions. Firstly, Post classification change detection technique was used to prepare time series LULC maps of the years 1987, 2000 and 2011. The overall classification accuracy of 86% and Kappa Coefficient (K) of 0.82 were achieved. Then model was manually calibrated using monthly historical streamflow records. The calibration was successful with coefficient of determination (R 2) value of 0.61 and the Nash and Sutcliffe efficiency value of 0.55. Validation of the calibrated model using independent dataset shows even better model performance with Nash and Sutcliffe efficiency value of 0.62 and R 2 value of 0.85. The results of this research study are as follows. Agriculture area in Palas Basin considerably expanded (47%) in the last 24 years. Consequently, the area of bare soil declined (36%) markedly during the period 1987–2011. Simulations of runoff for the 2000–2011 period with the SWAT model showed that, under the LULC conditions of 1987, surface runoff would be 40% lower compared to runoff under the LULC conditions of 2011. For the development of sustainable water resource strategies, it is essential to establish interaction between land use changes and local hydrology. Although more observed data is needed for model accuracy, SWAT can provide useful data for water sources planners and policy makers.

1 July 2010 in Water Science & Technology
Verified
Journal Article
Closed access
OOOktay Ozkan
Oktay Ozkan
HMH. Mıhçıokur
H. Mıhçıokur
ŞAŞükrü Taner AZGIN
Şükrü Taner AZGIN
ÖÖÖ. Özdemir
Ö. Özdemir
Wastewater from a medical-waste sterilisation plant (MWSP) contains unique pollutants and requires on-site treatment to prevent contamination of the municipal sewage system and receiving water bodies. Therefore, to meet the prescribed discharge standards and comply with the legal regulations, pre-treatment must be applied to MWSP wastewater. In this study, the capabilities of coagulation-flocculation processes were investigated for MWSP wastewater treatment. Processes using ferric chloride, ferrous sulfate and aluminium sulfate as coagulants were characterised. During the coagulation experiments, seven different coagulant dosages and four different pH values were evaluated to determine the optimum coagulant dosage and pH value. The highest removal efficiency of chemical oxygen demand (COD) was obtained using 300 mg/L of ferric chloride at pH 10. A COD removal of about 60% as well as considerable reductions in the amounts of suspended solids, nitrogen and phosphorus were realised.

11 May 2015 in Journal of Water and Climate Change
Verified
Journal Article
Closed access
PDF file
ŞAŞükrü Taner AZGIN
Şükrü Taner AZGIN
FDFiliz Dadaser-Celik
Filiz Dadaser-Celik
Saline lakes are widespread throughout the arid and semi-arid regions of the world and have considerable ecological importance. They are also very vulnerable to climatic changes or changes in their hydrological regimes. Most saline lakes of Turkey are close to the verge of extinction due to natural and anthropogenic impacts. This study analyzes the spatial and temporal changes at a relatively pristine saline lake (Tuzla (Palas) Lake) in Kayseri, Turkey, from 1987 to 2011 using satellite imagery techniques. Landsat Thematic Mapper images acquired in 1987, 2000, 2003, and 2011 were used in the analysis. The images were geometrically corrected by registering them to ground control points. The study area on each image was classified into seven information classes, i.e., water, watery ground, dry lake, mud/vegetated flats, salt flats, shrubs/sedges, and agriculture. The accuracies of the classifications were evaluated using a standard error matrix and kappa statistics. The analysis showed that the surface area of Tuzla Lake was highly variable during the 1987–2011 period. Lake surface area was the largest in 1987 and the smallest in 2003. Analysis of the climatic conditions for 4 years showed that the surface area of the lake is highly vulnerable to changes in precipitation and air temperatures.

12 January 2020 in Doğal Afetler ve Çevre Dergisi
Verified
Journal Article
Open access
PDF file
FDFiliz Dadaser-Celik
Filiz Dadaser-Celik
ŞAŞükrü Taner AZGIN
Şükrü Taner AZGIN
This study presents an air pollutant emission inventory of primary pollutants for Kayseri, Turkey. Kayseri is one of the largest cities in Turkey which went through industrialization in recent decades together with rapid population growth. Air pollution from residential, industrial, and transportation sources have been a major problem for Kayseri during this period. In this study, emissions of four primary pollutants, namely, particulate matter (PM), sulfur dioxide (SO2), nitrogen oxides (NOx), and carbon monoxide (CO) were estimate. The sources of air pollutants in Kayseri were classified as point, area, and line sources. The emissions from point and area sources (i.e., industrial and residential areas) were estimated by using the information on types and amounts of fuels used. The emissions from line sources (i.e., transportation) were estimated by using the vehicle count data on major roads. The appropriate emission factors were obtained from the Unites State Environmental Protection Agency or European Environment Agency. The results showed that the annual emission rates for PM, SO2, NOX and CO were 2929 tons,5082 tons, 6791 tons and 37094 tons, respectively. Area sources are responsible for 86%, 94%, and 75% of total PM, SO2, and CO emissions, respectively. Point sources provide about 56% of total NOX emissions. In order to improve the air quality of our cities, it is envisaged that control measures should be taken especially for reducing the residential emissions caused by heating and the determination of national emission calculation factors in order to achieve more reliable results.