Richard David Oleschuk

Prof. Dr. Richard David Oleschuk


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 December 2005 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
LBLaurie Brown
Laurie Brown
TKTerry Koerner
Terry Koerner
JHJ. Hugh Horton
J. Hugh Horton
RORichard David Oleschuk
Richard David Oleschuk
The fabrication of polymer microchips allows inexpensive, durable, high-throughput and disposable devices to be made. Poly(methylmethacrylate) (PMMA) microchips have been fabricated by hot embossing microstructures into the substrate followed by bonding a cover plate. Different surface modifications have been examined to enhance substrate and cover plate adhesion, including: air plasma treatment, and both acid catalyzed hydrolysis and aminolysis of the acrylate to yield carboxyl and amine-terminated PMMA surfaces. Unmodified PMMA surfaces were also studied. The substrate and cover plate adhesion strengths were found to increase with the hydrophilicity of the PMMA surface and reached a peak at 600 kN m−2 for plasma treated PMMA. A solvent assisted system has also been designed to soften less than 50 nm of the surface of PMMA during bonding, while still maintaining microchannel integrity. The extent to which both surface modifications and solvent treatment affected the adhesion of the substrate to the cover plate was examined using nanoindentation methods. The solvent bonding system greatly increased the adhesion strengths for both unmodified and modified PMMA, with a maximum adhesion force of 5500 kN m−2 achieved for unmodified PMMA substrates. The bond strength decreased with increasing surface hydrophilicity after solvent bonding, a trend that was opposite to what was observed for non-solvent thermal bonding.

28 May 2009 in Mass Spectrometry Reviews
Verified
Journal Article
Closed access
PDF file
GGGraham T.T. Gibson
Graham T.T. Gibson
Samuel MugoSamuel Mugo
Samuel Mugo
RORichard David Oleschuk
Richard David Oleschuk

16 November 2017 in Analytical Chemistry
Verified
Journal Article
Closed access
XYXilong Yuan
Xilong Yuan
RORichard David Oleschuk
Richard David Oleschuk

28 April 2003 in Electrophoresis
Verified
Journal Article
Closed access
PDF file
BWBin Wang
Bin Wang
ZKZamin A. Kanji
Zamin A. Kanji
EDEmily Dodwell
Emily Dodwell
JHJ. Hugh Horton
J. Hugh Horton
RORichard David Oleschuk
Richard David Oleschuk

15 February 2017 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
KBK. J. Bachus
K. J. Bachus
LML. Mats
L. Mats
HCH. W. Choi
H. W. Choi
GGG. T. T. Gibson
G. T. T. Gibson
RORichard David Oleschuk
Richard David Oleschuk

17 October 2017 in Analytical Chemistry
Verified
Journal Article
Open access
GSG. Ij. Salentijn
G. Ij. Salentijn
RORichard David Oleschuk
Richard David Oleschuk
EVElisabeth Verpoorte
Elisabeth Verpoorte
In this work we present the application of 3D-printing for the miniaturization and functionalization of an ion source for (portable) mass spectrometry (MS). Two versions of a 3D-printed cartridge for paper spray ionization (PSI) are demonstrated, assessed, and compared. We first focus on the use of 3D-printing to enable the integration of an embedded electrostatic lens and a manifold for internal sheath gas distribution and delivery. Cartridges with and without a sheath gas manifold and an electrostatic lens are compared with respect to analytical performance and operational flexibility. The sensitivity and limit of detection are improved in the cartridge with an electrostatic lens and sheath gas manifold compared to the cartridge without (15% and over 6.5× smaller, respectively). The use of these focusing elements also improved the average spray stability. Furthermore, the range of potentials required for PSI was lower, and the distance to the MS orifice over which spray could be obtained was larger. Importantly, both setups allowed quantification of a model drug in the ng/mL range with single-stage MS, after correction for spray instability. Finally, we believe that this work is an example of the impact that 3D-printing will have on the future of analytical device fabrication, miniaturization, and functionalization.