Werenfrid Wimmer

Dr. Werenfrid Wimmer

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Robert BrewinRobert Brewin
Robert Brewin
TBThomas G. Brewin
Thomas G. Brewin
JPJoseph Phillips
Joseph Phillips
SRSophie Rose
Sophie Rose
Anas AbdulazizAnas Abdulaziz
Anas Abdulaziz
Trevor PlattTrevor Platt
Trevor Platt
Two expanding areas of science and technology are citizen science and three-dimensional (3D) printing. Citizen science has a proven capability to generate reliable data and contribute to unexpected scientific discovery. It can put science into the hands of the citizens, increasing understanding, promoting environmental stewardship, and leading to the production of large databases for use in environmental monitoring. 3D printing has the potential to create cheap, bespoke scientific instruments that have formerly required dedicated facilities to assemble. It can put instrument manufacturing into the hands of any citizen who has access to a 3D printer. In this paper, we present a simple hand-held device designed to measure the Secchi depth and water colour (Forel Ule scale) of lake, estuarine and nearshore regions. The device is manufactured with marine resistant materials (mostly biodegradable) using a 3D printer and basic workshop tools. It is inexpensive to manufacture, lightweight, easy to use, and accessible to a wide range of users. It builds on a long tradition in optical limnology and oceanography, but is modified for ease of operation in smaller water bodies, and from small watercraft and platforms. We provide detailed instructions on how to build the device and highlight examples of its use for scientific education, citizen science, satellite validation of ocean colour data, and low-cost monitoring of water clarity, colour and temperature.

1 January 2012 in Remote Sensing of Environment
Verified
Journal Article
Closed access
WWWerenfrid Wimmer
Werenfrid Wimmer
IRIan S. Robinson
Ian S. Robinson
CDCraig Donlon
Craig Donlon

28 February 2006 in Renewable Energy
Verified
Journal Article
Closed access
WWWerenfrid Wimmer
Werenfrid Wimmer
PCPeter Challenor
Peter Challenor
CRChris Retzler
Chris Retzler

1 November 2016 in Journal of Atmospheric and Oceanic Technology
Verified
Journal Article
Open access
WWWerenfrid Wimmer
Werenfrid Wimmer
IRIan S. Robinson
Ian S. Robinson
Measurements of sea surface temperature at the skin interface ( ) made by an Infrared Sea Surface Temperature Autonomous Radiometer (ISAR) have been used for a number of years to validate satellite sea surface temperature (SST), especially high-accuracy observations such as made by the Advanced Along-Track Scanning Radiometer (AATSR). The ISAR instrument accuracy for measuring is ±0.1 K (Donlon et al.), but to satisfy Quality Assurance Framework for Earth Observation (QA4EO) principles and metrological standards (Joint Committee for Guides in Metrology), an uncertainty model is required. To develop the ISAR uncertainty model, all sources of uncertainty in the instrument are analyzed and an uncertainty value is assigned to each component. Finally, the individual uncertainty components are propagated through the ISAR retrieval algorithm to estimate a total uncertainty for each measurement. The resulting ISAR uncertainty model applied to a 12-yr archive of measurements from the Bay of Biscay shows that 77.6% of the data are expected to be within ±0.1 K and a further 17.2% are within 0.2 K.

24 February 2021 in Remote Sensing
Verified
Journal Article
Open access
PDF file
Robert BrewinRobert Brewin
Robert Brewin
WWWerenfrid Wimmer
Werenfrid Wimmer
Philip BresnahanPhilip Bresnahan
Philip Bresnahan
TCTyler Cyronak
Tyler Cyronak
AAAndreas J. Andersson
Andreas J. Andersson
GDGiorgio Dall'Olmo
Giorgio Dall'Olmo
The accuracy and precision of satellite sea surface temperature (SST) products in nearshore coastal waters are not well known, owing to a lack of in-situ data available for validation. It has been suggested that recreational watersports enthusiasts, who immerse themselves in nearshore coastal waters, be used as a platform to improve sampling and fill this gap. One tool that has been used worldwide by surfers is the Smartfin, which contains a temperature sensor integrated into a surfboard fin. If tools such as the Smartfin are to be considered for satellite validation work, they must be carefully evaluated against state-of-the-art techniques to quantify data quality. In this study, we developed a Simple Oceanographic floating Device (SOD), designed to float on the ocean surface, and deployed it during the 28th Atlantic Meridional Transect (AMT28) research cruise (September and October 2018). We attached a Smartfin to the underside of the SOD, which measured temperature at a depth of ∼0.1 m, in a manner consistent with how it collects data on a surfboard. Additional temperature sensors (an iButton and a TidbiT v2), shaded and positioned a depth of ∼1 m, were also attached to the SOD at some of the stations. Four laboratory comparisons of the SOD sensors (Smartfin, iButton and TidbiT v2) with an accurate temperature probe (±0.0043 K over a range of 273.15 to 323.15 K) were also conducted during the AMT28 voyage, over a temperature range of 290–309 K in a recirculating water bath. Mean differences (δ), referenced to the temperature probe, were removed from the iButton (δ=0.292 K) and a TidbiT v2 sensors (δ=0.089 K), but not from the Smartfin, as it was found to be in excellent agreement with the temperature probe (δ=0.005 K). The SOD was deployed for 20 min periods at 62 stations (predawn and noon) spanning 100 degrees latitude and a gradient in SST of 19 K. Simultaneous measurements of skin SST were collected using an Infrared Sea surface temperature Autonomous Radiometer (ISAR), a state-of-the-art instrument used for satellite validation. Additionally, we extracted simultaneous SST measurements, collected at slightly different depths, from an underway conductivity, temperature and depth (CTD) system. Over all 62 stations, the mean difference (δ) and mean absolute difference (ϵ) between Smartfin and the underway CTD were −0.01 and 0.06 K respectively (similar results obtained from comparisons between Smartfin and iButton and Smartfin and TidbiT v2), and the δ and ϵ between Smartfin and ISAR were 0.09 and 0.12 K respectively. In both comparisons, statistics varied between noon and predawn stations, with differences related to environmental variability (wind speed and sea-air temperature differences) and depth of sampling. Our results add confidence to the use of Smartfin as a citizen science tool for evaluating satellite SST data, and data collected using the SOD and ISAR were shown to be useful for quantifying near-surface temperature gradients.

9 May 2026 in Remote Sensing
Verified
Journal Article
Open access
PDF file
WWWerenfrid Wimmer
Werenfrid Wimmer
TNTim Nightingale
Tim Nightingale
ALArrow Lee
Arrow Lee
JHJacob Høyer
Jacob Høyer
GGGuisella Gacitúa
Guisella Gacitúa
CDCraig Donlon
Craig Donlon
SST data derived from multi-spectral infrared measurements made by the SLSTR instruments onboard the Copernicus Sentinel-3 satellites are considered reference measurements based on the design features of the SLSTR instrument. This means that regular long-term validation of the end-to-end performance using independent reference data is essential. This paper presents a sustained SLSTR SST validation activity between 2018 and 2025 based on an extensive set of near-contemporaneous and co-located in situ reference measurements. In situ measurements are derived from high-performance shipborne infrared radiometers that are calibrated regularly against International System of Units (SI) reference standards maintained by a National Metrology Institute (NMI). As such, they are classified as FRMs. The shipborne radiometers are operated by several organizations that co-operate within the International Shipborne FRM Radiometer Network (ISFRN), under the auspices of the European Space Agency (ESA) ships4sst project (a quasi-operational SSTskin measurement program with a common data format and traceable measurements). The mean measured differences between the SLSTR on Sentinel-3A (S3A) and the ships4sst FRM data are −0.01 K with a RSD of 0.20 K for nighttime retrievals and 0.07 K with an RSD of 0.27 K for daytime retrievals. For Sentinel-3B (S3B), the mean measured differences between the SLSTR and the ships4sst data are −0.04 K with an RSD of 0.19 K for nighttime retrievals, and 0.03 K with an RSD of 0.27 K for daytime retrievals. Our comparisons validate the consistency and performance of the Copernicus Sentinel-3 SLSTR SST data and provide the means to link these satellite measurements to NMI reference standards, which is essential for justifying the status of SLSTR SST data as a CDR.