Arrow Lee

Dr. Arrow Lee

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 August 2020 in Remote Sensing
Verified
Journal Article
Open access
PDF file
DSDavid Smith
David Smith
MBMarc Barillot
Marc Barillot
SBStephane Bianchi
Stephane Bianchi
FBFabio Brandani
Fabio Brandani
PCPeter Coppo
Peter Coppo
EPEdward Polehampton
Edward Polehampton
The first two models of the Sea and Land Surface Temperature Radiometers (SLSTR) for the European Copernicus Sentinel-3 missions were tested prior to launch at the Rutherford Appleton Laboratory space instrument calibration facility. The pre-launch tests provide an essential reference that ensures that the flight data of SLSTR are calibrated to the same standards needed for surface temperature measurements and to those used by shipborne radiometers for Fiducial Reference Measurement (FRM). The radiometric calibrations of the thermal infrared channels were validated against accurate and traceable reference BB sources under flight representative thermal vacuum environment. Measurements were performed in both earth views for source temperatures covering the main operating range, for different instrument configurations and for the full field-of-view of the instruments. The data were used to derive non-linearity curves to be used in the level-1 processing. All results showed that the measured brightness temperatures and radiometric noise agreed within the requirements for the mission. An inconsistency that particularly affected SLSTR-A was observed which has been attributed to an internal stray light error. A correction for the stray light has been proposed to reduce the error. The internal stray light error was reduced for SLSTR-B by replacing the coating on the main aperture stop. We present a description of the test methodology and the key results.

9 May 2026 in Remote Sensing
Verified
Journal Article
Open access
PDF file
WWWerenfrid Wimmer
Werenfrid Wimmer
TNTim Nightingale
Tim Nightingale
ALArrow Lee
Arrow Lee
JHJacob Høyer
Jacob Høyer
GGGuisella Gacitúa
Guisella Gacitúa
CDCraig Donlon
Craig Donlon
SST data derived from multi-spectral infrared measurements made by the SLSTR instruments onboard the Copernicus Sentinel-3 satellites are considered reference measurements based on the design features of the SLSTR instrument. This means that regular long-term validation of the end-to-end performance using independent reference data is essential. This paper presents a sustained SLSTR SST validation activity between 2018 and 2025 based on an extensive set of near-contemporaneous and co-located in situ reference measurements. In situ measurements are derived from high-performance shipborne infrared radiometers that are calibrated regularly against International System of Units (SI) reference standards maintained by a National Metrology Institute (NMI). As such, they are classified as FRMs. The shipborne radiometers are operated by several organizations that co-operate within the International Shipborne FRM Radiometer Network (ISFRN), under the auspices of the European Space Agency (ESA) ships4sst project (a quasi-operational SSTskin measurement program with a common data format and traceable measurements). The mean measured differences between the SLSTR on Sentinel-3A (S3A) and the ships4sst FRM data are −0.01 K with a RSD of 0.20 K for nighttime retrievals and 0.07 K with an RSD of 0.27 K for daytime retrievals. For Sentinel-3B (S3B), the mean measured differences between the SLSTR and the ships4sst data are −0.04 K with an RSD of 0.19 K for nighttime retrievals, and 0.03 K with an RSD of 0.27 K for daytime retrievals. Our comparisons validate the consistency and performance of the Copernicus Sentinel-3 SLSTR SST data and provide the means to link these satellite measurements to NMI reference standards, which is essential for justifying the status of SLSTR SST data as a CDR.

23 March 2020
Verified
Conference Paper
Open access
TNTim Nightingale
Tim Nightingale
RMRobert McPheat
Robert McPheat
ALArrow Lee
Arrow Lee
EPEdward Polehampton
Edward Polehampton
EPEttore Pedretti
Ettore Pedretti
HMHugh Mortimer
Hugh Mortimer
We describe a novel technique – Fourier transform spectroscopy – that we have developed to characterise the spectral and polarisation responses of the Sentinel-3 SLSTR optical channels. Our method has a number of advantages over conventional approaches employing a grating monochromator, including excellent spectral registration and resolution, intrinsic rejection of self-emission from the test setup and fast measurement times. Our measurements are traceable, through the spectral responsivity of a reference detector and the wavelength of a HeNe laser, to national standards.We illustrate our method with sample results from the spectral calibrations of the four SLSTR focal plane assemblies tested to date.