In this paper the dynamic behavior of different wind turbine generator configurations including doubly fed induction generators (DFIG), squirrel cage induction generator (SCIG), wound rotor induction generator (WRIG), and permanent magnet synchronous generator (PMSG) under ferroresonant conditions of energization and de-energization was investigated using Simulink/MATLAB (version 2017B, MathWorks, Natick, MA, USA). The result showed that SCIG had the highest overvoltage of 10.1 PU during energization, followed by WRIG and PMSG, while the least was DFIG. During de-energization, PMSG had the highest overvoltage of 9.58 PU while WRIG had the least. Characterization of the ferroresonance was done using a phase plane diagram to identify the harmfulness of the ferroresonance existing in the system. It was observed that for most of the wind turbine configurations, a chaotic mode of ferroresonance exists for both energization and de-energization scenarios. Although overvoltage during energization for wind turbine generator configurations was higher than in the de-energization with an exception of PMSG, their phase plane diagrams showed that de-energization scenarios were more chaotic than energization scenarios. The study showed that WRIG was the least susceptible to ferroresonance while PMSG was the most susceptible to ferroresonance.

27 August 2020 in Energies
Verified
Journal Article
Open access
PDF file
AAAjibola Akinrinde
Ajibola Akinrinde
ASAndrew Swanson
Andrew Swanson
Innocent Ewean DavidsonInnocent Ewean Davidson
Innocent Ewean Davidson
The Ferranti effect could cause a rise in voltage along the cables on a wind farm if the circuit breakers at the receiving ends are switched off. Ferroresonance could also occur due to stuck pole(s) of the circuit breaker during de-energization. This paper reports on the temporary overvoltage (TOV) arising from the de-energization of the circuit breaker connecting the wind turbine to the feeder, the feeder breaker connecting an array of wind turbines to the point of common coupling (PCC), and the opening of the circuit breaker connecting the onshore to the offshore substation. Ferroresonance was characterized using a phase plane diagram and Poincaré map and was identified to be chaotic. The effect of the nonlinear characteristic of the wind transformer core on the ferroresonant overvoltage was examined and increased with the steepness of slope of the transformer curve. A damping resistor, shunt reactor and surge arrester were used to mitigate the overvoltage experienced during the ferroresonant event. The damping resistor was able to reduce the overvoltage to 1.24 P.U. and damped the ferroresonance from chaotic to fundamental mode.

1 June 2019 in Indonesian Journal of Electrical Engineering and Computer Science
Verified
Journal Article
Open access
PDF file
AAAjibola Akinrinde
Ajibola Akinrinde
ASAndrew Swanson
Andrew Swanson
RTRemy Tiako
Remy Tiako
Effect of Ferroresonance on Wind Turbine: Comparison of Atp/Emtp and Matlab/Simulink

1 January 2018 in International Journal of Engineering Research in Africa
Verified
Journal Article
Closed access
PDF file
AAAjibola Akinrinde
Ajibola Akinrinde
ASAndrew Swanson
Andrew Swanson
RTRemy Tiako
Remy Tiako
Temporary overvoltages caused by primary and secondary islanding due to a fault on a hybrid microgrid of a wind energy and PV system that was connected to the grid, was considered in this study. Symmetry opening of three poles opening and nuisance opening of circuit breaker leading to ferroresonance were investigated using ATP/EMTP. The findings show that during primary islanding an overvoltage of 5.60 P.U. was observed and 7.05 P.U. during secondary islanding. An overvoltage of 3.43 P.U. was experienced during an event of ferroresonance, which could be suppressed by transposing the cable and by connecting a resistive load which is 1% of rated transformer. The effect of the length of the cable on the ferroresonant overvoltage was also studied and found to decrease with the increase of the length of cable.